GE NetworX NX-6V2 Installation And Startup page 20

Hide thumbs Also See for NetworX NX-6V2:
Table of Contents

Advertisement

Segment 9 -
Fire Alarm Verification time in seconds 120-255 seconds .................................... (0 = no fire alarm verification)
NOTE: The fire alarm verification feature is not approved for residential use in California
Segment 10 -
Listen-In time in seconds 0-255............................................................................ (0 = no Listen-In time)
Segment 11 -
Zone Activity Monitor feature timed in days 0 – 255 ............................................. (0 = disabled)
Segments 12-14 Reserved.
41
Segment 1:
1 =
On enables the 6-digit code option. If 6-digit option is enabled, all arm/disarm codes and the "Go To Program Code" are 6
digits. If this option is enabled, the default user 1 code is [1]-[2]-[3]-[4]-[5]-[6].
NOTE: IF YOU ENABLE THIS OPTION, VERIFY THAT THE "GO TO PROGRAM CODE" IS A SIX-DIGIT CODE
BEFORE EXITING PROGRAMMING.
2 =
On requires code entry for [r]-[9]-[8] (perform call back download) and [r]-[9]-[9] (answer incoming call for download)
functions.
3 =
Enable Auto Cancel / Abort (Refer to Glossary beginning on page 39)
4 =
Enable Walk-Test Mode (Refer to Glossary beginning on page 39)
5 =
On enables Auto Force-Arming with keyfob or keyswitch.
6 =
Reserved.
7 =
Reserved.
8 =
Reserved. (Do not program!)
L
42
Location 42 contains the "Go To Program Code". This location contains either a 4 or 6-digit code. If the 6-digit code option is enabled
in Location 41, THIS CODE MUST CONTAIN SIX (6) DIGITS. If this option is not enabled in location 41, the last 2 segments (digits)
will be ignored. With the NX-6V2 disarmed, the "Go To Program Code" can be used to enter the Program Mode.
43
The "Go To Program Code" can be used as a standard arm/disarm code. When using the code to arm or disarm, the user ID is 255.
(This code may not be changed in the Run Mode.)
Segment 1:
1 = Reserved.
2 = On enables "Go To Program Code" as an arm only code.
3 = On enables "Go To Program Code" as an arm only after closing.
4 = On enables "Go To Program Code" as a master arm/disarm code (can change user codes)
5 = On enables "Go To Program Code" as an arm/disarm code.
6 = On enables "Go To Program Code" to bypass zones.
7 = On enables "Go To Program Code" opening and closing reports.
8 = Reserved.
Segment 2:
1 = On enables the "Go To Program Code" for Partition #1.
2 = On enables the "Go To Program Code" for Partition #2.
3-8 = Reserved.
L
44
Location 44 contains the "Duress" code. This Location contains either 4 or 6 digits. If the 6-digit code option is enabled in Location 41,
THIS CODE MUST CONTAIN SIX (6) DIGITS. If the 6-digit option is not enabled in location 41, the last 2 digits will be ignored. If the
duress code is programmed, it will work for all partitions.
45
Location 45 is used to select which partition(s) the events must occur in before the output will activate. Location 45 has 4 segments.
Segment 1 corresponds to output 1, and Segment 4 corresponds to output 4.
Segment 1 (Aux 1)
1= Partition 1
2= Partition 2
20
SPECIAL FEATURES
GO TO PROGRAM CODE
GO TO PROGRAM CODE PARTITION & AUTHORIZATION
DURESS CODE
AUXILIARY OUTPUT 1-4 PARTITION SELECTION
Segment 2 (Aux 2)
1= Partition 1
2= Partition 2
Segment 3 (Aux 3)
1= Partition 1
2= Partition 2
1 ............ feature select
6 ............ numerical
2 ............ feature select
6 ............ numerical
4 ............ feature select
Segment 4 (Aux 4)
1= Partition 1
2= Partition 2
NX-6V2 Control

Advertisement

Table of Contents
loading

Table of Contents