LOC
PG
49
21
AUXILIARY OUTPUT #3, EVENT & TIME
Segment 1: Event number for output # 3
Segment 2: Timing for output # 3
50
21
AUXILIARY OUTPUT #4, EVENT & TIME
Segment 1: Event number for output # 4
Segment 2: Timing for output # 4
51
22
AUTOTEST CONTROL
L
Segment 1:
to suppress the daily test or a A3" to suppress the hourly test.
Segment 2: Program the autotest interval from 1-255 days or hours.
Segment 3: Program the autotest report in 24-hour time format.
Segment 4: Program the autotest report time, minutes after the
hour.
52
22
OPENING TIME
Segment 1: Program the hour of the opening time.
Segment 2: Program the minutes after the hour of opening time.
53
22
CLOSING TIME / AUTO ARMING TIME
Segment 1: Program the hour of closing time / auto arming time.
Segment 2: Program the minutes after hour of closing / auto arming
time.
54
22
DAYS OF THE WEEK EACH PARTITION IS OPEN
Segments:
Partition 1
Partition 2
55
22
DAYS OF THE WEEK "AUTO ARMING" WILL OCCUR IN PARTITIONS
Segments:
Partition 1
Partition 2
The digit programmed in each of the following locations will be sent as the upper HEX digit in place of the alarm event code.
The zone ID or user ID will always be reported as the lower HEX digit (1-F). For example, if the zone ID or user ID is 15, the 4+2
lower digit will be "F". (Refer to Appendix 4 on page Error! Bookmark not defined..)
If Segment 2 is left as "0" (unprogrammed), it will follow the Segment 1 selection.
If Segment 1 is left as "0" and the feature is enabled, the NX-6V2 will report ""A".
LOC
PG
56
23
RESTORE COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY
Segment 1: Partition 1 Restore code
Segment 2: Partition 2 Restore code
57
23
BYPASS COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY
Segment 1: Partition 1 Bypass code
Segment 2: Partition 2 Bypass code
58
23
TAMPER COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY
Segment 1: Partition 1 Tamper Code
Segment 2: Partition 2 Tamper Code
59
23
TROUBLE COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY
Segment 1: Partition 1 Trouble Code
Segment 2: Partition 2 Trouble Code
60
23
SENSOR LOW BATTERY COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY
Seg 1: Partition 1 Sensor Low Battery Code
Seg 2: Partition 2 Sensor Low Battery Code
61
23
SENSOR MISSING COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY
Seg 1: Partition 1 Sensor Missing Code
Seg 2: Partition 2 Sensor Missing Code
62
23
DURESS
63
23
AUXILIARY 1
64
23
AUXILIARY 2
65
23
KEYPAD PANIC
66
23
KEYPAD MULTIPLE CODE ENTRY TAMPER
67
23
BOX TAMPER / BOX TAMPER RESTORE
68
23
AC FAIL / AC RESTORE
69
23
LOW BATTERY / LOW BATTERY RESTORE
70
24
POWER SHORT / POWER SHORT RESTORE
71
24
BELL TAMPER / BELL TAMPER RESTORE
72
24
TELEPHONE LINE CUT / LINE CUT RESTORE
NX-6V2 Control
DESCRIPTION
Program a "1" if the interval is hours, a "0" if in days. Add a A2"
Sunday
Monday
1
2
1
2
Sunday
Monday
1
2
1
2
COMMUNICATOR CODES FOR SLOW SPEED FORMATS ONLY
DESCRIPTION
DEFAULT
2= 24 Hour Alarm
0=
Tuesday
Wednesday
Thursday
3
4
3
4
Tuesday
Wednesday
Thursday
3
4
3
4
DEFAULT
0
0
0
0
0
0
0
0
0
0
0
0
0-0
0-0
0-0
0-0
0-0
0-0-0-0
0-0-0-0
0-0-0-0
0-0-0-0
0-0-0-0
0-0-0-0
PROGRAM DATA
10 seconds
21-Armed State
Follow condition
1
24
2
0
8
0
20
0
Friday
Saturday
5
6
7
5
6
7
Friday
Saturday
5
6
7
5
6
7
PROGRAMMING DATA
_ _
_ _
_ _
_ _
_ _
_ _ _ _
_ _ _ _
_ _ _ _
_ _ _ _
_ _ _ _
_ _ _ _
Reserved
8
8
Reserved
8
8
_
_
_
_
_
_
_
_
_
_
_
_
35