GE NetworX NX-6V2 Installation And Startup page 17

Hide thumbs Also See for NetworX NX-6V2:
Table of Contents

Advertisement

DATA
ENTRY/EXIT DELAY 2- A trip will start entry delay 2. The lack of a trip during exit delay will enable the Automatic
9
Bypass or Instant mode if so programmed.
24-HOUR SILENT SUPERVISED- Creates an instant silent alarm regardless of the armed state of the control panel. It
10
will display on the keypad.
KEYSWITCH ZONE - This zone type will arm and disarm the partition or partitions of the control panel that it resides in
11
each time the zone is shorted. Keyswitch arming will report as user #99.
INTERIOR FOLLOWER WITH "CROSS ZONE" ENABLED - This zone will be instant when the system is armed and no
entry or exit delay is being timed. It is delayed during entry and exit delay times. If a "Cross Zone" is not being timed it will
12
start a "Cross Zone" timer. If a "Cross Zone" is being timed it will create an instant alarm. This zone will automatically
bypass when enabled in Segment 1 of Location 23.
INSTANT ENTRY GUARD - This zone creates an instant alarm whenever it is tripped and the Stay LED is off. It will start
13
an entry delay time 2 if it is tripped and the system is armed and the Stay LED is on.
ENTRY/EXIT DELAY 1 WITH GROUP BYPASS ENABLED - A trip will start entry delay 1. This zone will bypass when
14
the "Group Bypass" command is entered at the keypad. The lack of a trip during exit delay will enable the Automatic
Bypass or Instant mode if so programmed.
INTERIOR FOLLOWER WITH GROUP BYPASS ENABLED - This zone will be instant when the system is armed and no
15
entry or exit delays are being timed. It is delayed during entry/exit delay times. This zone will bypass when the "Group
Bypass" command is entered at the keypad. This zone will automatically bypass if enabled in Segment 1 of Location 23.
INSTANT WITH GROUP BYPASS ENABLED - This zone creates an instant alarm whenever it is tripped and the Armed
16
LED is on. This zone will bypass when the "Group Bypass" command is entered at the keypad.
ENTRY/EXIT DELAY 1 WITH TAMPER ENABLED- A trip will start entry delay 1. The lack of a trip during exit delay will
17
enable the Automatic Bypass or Instant mode if so programmed. This zone type can be used to enable tamper on a
wireless transmitter.
INTERIOR FOLLOWER WITH TAMPER AND AUTO-BYPASS ENABLED - This zone will be instant when the system is
armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times. This zone will
18
automatically bypass if enabled in Segment 1 of Location 23. This zone type can be used to enable tamper on a
wireless transmitter.
INSTANT WITH TAMPER ENABLED - This zone creates an instant alarm whenever it is tripped and the Armed LED is
19
on. This zone type can be used to enable tamper on a wireless transmitter.
ENTRY/EXIT DELAY 2 WITH TAMPER ENABLED-A trip will start entry delay 2. The lack of a trip during exit delay will
20
enable the Automatic Bypass or Instant mode if so programmed. This zone type can be used to enable tamper on a
wireless transmitter.
GAS DETECTION- Creates an instant alarm regardless of the armed state of the control panel. It will display on the
21
keypad and activate the keypad sounder.
LOW TEMP DETECTION- Creates an instant silent alarm regardless of the armed state of the control panel. It will display
22
on the keypad and activate the keypad sounder.
HIGH TEMP DETECTION- Creates an instant silent alarm regardless of the armed state of the control panel. It will
23
display on the keypad and activate the keypad sounder.
MANUAL FIRE - This zone will illuminate the Fire LED and sound the temporal siren each time the zone is shorted. It will
24
also rapidly flash the Fire LED indicating a trouble if the zone is open.
CHIME ONLY - Creates no alarm regardless of the armed state of the control panel. It will chime anytime it is faulted and
25
will display on the keypad. Local only.
INTERIOR FOLLOWER DELAY 2 - This zone will be instant when the system is armed and no entry or exit delay is
26
being timed. It is delayed during entry and exit delay 2 times. This zone will automatically bypass if enabled in Segment 1
of Location 23.
INTERIOR FOLLOWER FORCE ARMABLE - This zone will be instant when the system is armed and no entry or exit
27
delay is being timed. It is delayed during entry and exit delay 1 times. This zone will automatically bypass if enabled in
Segment 1 of Location 23.
ENTRY/EXIT FORCE ARMABLE DELAY 2 - A trip will start entry delay 2. The lack of a trip during exit delay will enable
28
the Automatic Bypass or Instant mode if so programmed.
INTERIOR FOLLOWER WITH ACTIVITY SUPERVISION ENABLED - This zone will be instant when the system is
armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times. It will send a report if the
29
zone activity time is reached without a change of state. Refer to Location 40 / Segment 11. This zone will automatically
bypass if enabled in Segment 1 of Location 23.
ENTRY/EXIT WITH ACTIVITY SUPERVISION ENABLED- A trip will start entry delay 1. It will send a report if the zone
30
activity time is reached without a change of state. Refer to Location 40 / Segment 11. The lack of a trip during exit delay
will enable the Automatic Bypass or Instant mode if so programmed.
NX-6V2 Control
DESCRIPTION OF DEFAULT ZONE TYPES
17

Advertisement

Table of Contents
loading

Table of Contents