Furuno FCV-628 Operator's Manual page 56

Table of Contents

Advertisement

[NMEA Port]: The NMEA terminals in the "12-
24 VDC/NMEA" port can function as input
ports or input/output port. Change the setting
to "In/In" when connecting GP-320B and a
wind sensor. When connecting the GP-320B
and a wind sensor, first turn on "WAAS Setup"
and then select [In/In] as the [NMEA Port] set-
ting. Only a wind speed/angle sensor that out-
puts the MWV sentence can be connected.
[In/Out]: Input and Output (default setting)
[In/In]: Input only (Available with connection of
both the GP-320B and a wind sensor.)
[NMEA Output]: Select what data sentences
to output.
[Off]: Output the "output data sentences".
[On]: Output the "output data sentences" and
sentences which are input from other equip-
ment.
[WAAS Setup]: Select how to use the WAAS
signal when connecting with a WAAS receiv-
er, for example GP-320B. The message types
(WAAS-00 to WAAS-27) are used as WAAS
correction. Select [WAAS-00] to enable
WAAS.
Note: This function is available only when [In/
Out] is selected at [NMEA Port].
[TLL Output]: Output the position specified
by the MARK key to the plotter connected.
[Off]: Do not output latitude/longitude.
[TLL]: Output latitude/longitude.
[FURUNO-TLL]: Output latitude/longitude,
depth and water temperature. Requires [FU-
RUNO-TLL] enabled device.
[Port Monitor]: Port Monitor shows the data
sentences input to the [12-24 VDC/NMEA]
port.
$GPGLL, 1353. 5678, N, 11111. 1111, E, , A, D*
4B<0d><0a>
$GNGNS, , 1111. 5751, S, 00013. 5596, E, D, , ,
, , , *3A<0d><0a>
$GPMWV, 111. 11, R, 11. 11, N, A*1B<0d><0a>
Press the ENTER key to display the latest
data sentence information. To display this in-
formation on the Port 2 screen when two sen-
sors are connected, set [NMEA Port] in the
[NMEA] menu to [In/In].
49