Condensate Piping - Carrier 40WAW007 Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

5in (
t 6 in. MIN.
Fig. 4 -- Required Clearances
5 in.
MIN.
The unit
should
not be positioned
directly
above
any
obstruction.
The unit must be installed
square and level.
The condensate
drain
should
have sufficient
downward
slope in the condensate
flow direction.
Step 3 E Mount the Unit
When determining the unit
mounting
location, make sure
that there are no water, plumbing, or electrical lines run-
ning through the wall. Failure to follow this instruction
may result in property damage.
1. Detach the mounting plate from the unit.
2. Place the mounting plate on the wall where the unit will
be installed and mark the mounting holes. See Fig. 5.
Be sure the mounting hole marks are positioned over the
wall studs.
!
I
[
28
MOUNTING
UNIT SIZES 007-012
PLATE
co
28-3/4
_,
311-3/8
MOUNTING
PLATE
UNIT SIZES 015-018
28-1/4
_
3_
TING
PLATE
UNIT SIZE 024
NOTE: All dimensions
in inches,
Fig. 5 -- Mounting Plate
3. Mark the condensate
and refrigerant piping route. If nec-
essary, cut hole in wall to route the piping.
4. Secure the mounting
plate with screws that can support
the weight of the unit. For nominal weight of the unit, see
Table 1.
5.
6.
Make sure the mounting
plate is leveled and flush with
the wall.
Secure the unit in position
by lifting the unit over the
mounting
plate. Make
sure the hook on the mounting
plate aligns with the slot on the back of the unit. To ensure
proper fit, slide the unit sideways.
If the unit is locked in
the correct position, it should not move.
Step 4 E Connect
Piping
GENERAL
1. For condensate
and refrigerant
piping, lift the unit from
bottom,
making
sure the unit
is still attached
to the
mounting plate at the top. See Fig. 6.
2. Introduce temporary
cushioning
material to maintain the
space needed to connect the piping and to avoid damage
to unit and wall. See Fig. 6.
HOOK
CUSHIONING
MATERIAL
Fig. 6 -- Piping Connection
3. When the piping connections
are completed,
remove the
cushioning
material and make sure the unit is flush with
the wall.
CONDENSATE PIPING-
The unit is supplied with a
3/4-in.
OD drain connection to connect copper or PVC drain
piping. When installing condensate piping, follow these recom-
mendations:
Condensate
drain should
slope downward
in the direc-
tion of condensate
flow.
• DO NOT install any U bends or dump the condensate
line in a sump filled with water. See Fig. 7.
Fig. 7 -- Condensate
Piping, Poor Installation
When multiple units are connected
to a colmnon
conden-
sate drain, ensure that the drain is large enough to accom-
modate the volume of condensate
from all units. It is also
recolmnended
to have an air vent in the condensate
pip-
ing to prevent
any air locks.
Condensate
piping must not be installed
where
it may be
exposed
to freezing
temperatures.
Condensate
piping
can be routed in one of the four direc-
tions shown in Fig. 8.