Carrier 40GXC Product Data

Carrier 40GXC Product Data

Inverter---driven high wall duct---free split system
Hide thumbs Also See for 40GXC:

Advertisement

40GXC / 38GXC
40GXQ / 38GXQ
Inverter---Driven High Wall Duct---Free Split System
Sizes 009 to 024
The ideal compliment to your ducted system when it is impractical
or prohibitively expensive to use ductwork.

Product Data

INDUSTRY LEADING
FEATURES / BENEFITS
AN INEXPENSIVE AND CREATIVE
SOLUTION TO DESIGN PROBLEMS.
The 38GXC(Q)/40GXC(Q) inverter driven duct- -free split systems
are a matched combination of an outdoor condensing unit and an
indoor fan coil unit connected only by refrigerant tubing and wires.
The fan coil is mounted on the wall, near the ceiling. This selection
of fan coils permits inexpensive and creative solutions to design
problems such as:
S
S
S
S
These compact indoor fan coil units take up very little space in the
room and do not obstruct windows. The fan coils are attractively
styled to blend with most room decors.
components incorporate innovative technology to provide reliable
cooling performance at low sound levels.
Add- -ons to current space (sun room)
Special space requirements
When adding air conditioning to spaces that are heated
by hydronic or electric heat and have no ductwork.
Historical renovations or any
preserving the look of the original structure is essential.
application where
Advanced system

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 40GXC

  • Page 1: Product Data

    FEATURES / BENEFITS AN INEXPENSIVE AND CREATIVE SOLUTION TO DESIGN PROBLEMS. The 38GXC(Q)/40GXC(Q) inverter driven duct- -free split systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires.
  • Page 2 INVERTER TECHNOLOGY - - COMFORT FAST INSTALLATION The inverter driven compressor is designed to run at various input This compact duct- -free split system is simple to install. A power frequencies (Hz) which controls the motor speed of the mounting bracket is standard with the indoor units and only wires compressor.
  • Page 3: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE INDOOR UNIT 1--- 01 Voltage Fan Coil Unit 1 --- 115 ---1 ---60 Nominal Capacity 009 --- 3/4 Ton Unit Type 012 --- 1 Ton GXC --- Cooling Only 018 --- 1 ---1/2 Ton GXQ --- Heat Pump 024 --- 2 Ton OUTDOOR UNIT 1--- 01...
  • Page 4: Standard Features And Accessories

    STANDARD FEATURES AND ACCESSORIES INDOOR UNITS Ease Of Installation Mounting Brackets Low Voltage Controls Comfort Features Microprocessor Controls Wireless Remote Control Rapid Cooling/Heating Automatic Air Sweep Cold Blow Prevention Continuous Fan * Auto Restart Feature Memory Function Auto Changeover Energy Saving Features Inverter Driven Compressor A07892 Fig.
  • Page 5 DIMENSIONS - - INDOOR A08289 Net Operating Weight Unit Size In. (mm) In. (mm) In. (mm) lb (kg) 30.3 (770) 9.8 (250) 7.84 (199) 18.7 (8.5) 12 K 32.7 (830) 11.2 (285) 8.9 (225) 24.2 (11) 18 K 37.5 (953) 12.0 (305) 8.1 (206) 26.4 (12)
  • Page 6 CLEARANCES - - INDOOR CEILING 6" (0.15m) min. 5" 5" (0.13m) (0.13m) min. min. (1.8m) FLOOR A07891 Fig. 4 – Indoor unit clearance CLEARANCES - - OUTDOOR Air-inlet Air-outlet A07894 UNIT 12k in. (mm) 20 (508) 20 (508) 24 (610) 12 (305) 12 (305) Fig.
  • Page 7: Physical Data

    1/2” 5/8” Maximum Length ft* Max Lift (Fan Coil Above) ft Max Drop (Fan Coil Below) ft External Finish White Indoor Unit 40GXC(Q) System Voltage 115 V 208/230 ---1 ---60 Control Voltage Low Voltage Pulse DC Electrical Connections Indoor Unit Powerd From Outdoor Unit...
  • Page 8: Application Data

    Indoor Temp. 80/67_F (26.7/19.4_C) (db/wb) --- Indoor Fan High Speed Indoor temperature 75_F (23.4_C) (db) --- Indoor Fan High Speed = Rating Point = Rating Point A09176 A09178 Fig. 6 – 38GXC(Q)009 / 40GXC(Q)009 Cooling Fig. 7 – 38GXQ009 / 40GXQ009 Heating 140% 140% 120% 120%...
  • Page 9 Indoor Temp. 80/67_F (26.7/19.4_C) (db/wb) --- Indoor Fan High Speed Indoor temperature 75_F (23.4_C) (db) --- Indoor Fan High Speed = Rating Point = Rating Point A10124 A10125 Fig. 10 – 38GXC(Q)018 / 40GXC(Q)018 Cooling Fig. 11 – 38GXQ018 / 40GXQ018 Heating 140.0% 120.00% 120.0% 100.00% 100.0%...
  • Page 10: Refrigerant Lines

    If unit is exposed to strong winds, it is Long Line Applications: recommended that a wind baffle be used. Contact your Carrier representative for drawings. Do not install the outdoor or indoor 1. A field fabricated wind baffle is recommended.
  • Page 11: Wireless Remote Control

    CONTROL SYSTEM will ramp up to approximately 85 Hz. The compressor will operate The 40GXC(Q)/38GXC(Q) unit is equipped with a microprocessor at this speed until the load is satisfied or a maximum of 20 minutes controls to operate the system and give optimum levels of comfort after which the compressor will shut off for 3 minutes.
  • Page 12: Outdoor Units

    AIR THROW DATA Approximate Air Throw ft. (m) Unit Size Medium High Turbo 18 (5.5) 20 (6.1) 23 (7.0) 12 K 19 (5.8) 21 (6.4) 25 (7.6) 18 K 25 (7.6) 30 (9.1) 32 (9.8) 35 (10.7) 24 K 23 (7.0) 27 (8.2) 30 (9.1) 37 (11.3)
  • Page 13: Guide Specifications

    GUIDE SPECIFICATIONS HORIZONTAL DISCHARGE OUTDOOR UNITS Size Range: 3/4 and 1 Ton Nominal Cooling and Heating Capacity Carrier Model Number: 38GXC(Q) PART 1 – GENERAL 1.01 System Description D. Compressor 1. Compressor shall be fully hermetic variable speed rotary A. Outdoor air-cooled split system compressor sections suitable type.
  • Page 14 1. Automatic restart after power failure at the same operating conditions as at failure. Catalog No. 38---40GX ---5PD Copyright 2011 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. Edition Date:05/11 Replaces: 38--- 40GX--- 4PD...

This manual is also suitable for:

38gxc40gxq38gxq