Port Sequential - Interlogix ES2402-24P-2C User Manual

Hide thumbs Also See for ES2402-24P-2C:
Table of Contents

Advertisement

4.9.4 Port Sequential

This page allows the user to configure the PoE Ports started up interval time.
switch is completely booted up
The configuration example is that if you want each PoE port is powered with 5 seconds interval, you have to set port1 with 5
seconds, port2 with 10 seconds and port3 with 15 seconds and etc.
If you just set 5 seconds for all ports, all ports will be powered at the same time after 5 seconds when system has finished
booting.
The PoE port will start providing power after the whole system program has finished running.
The page includes the following fields:
Object
• Delay Mode
• Delay Time (0 ~ 300)
seconds
• Port No.
The PoE Port Sequential Setting Status screen in
as
Figure 4-9-4
shows.
Figure 4-9-4: PoE Port Sequential Configuration Screenshot
Description
Allows user to enable or disable Sequential Power up function.
The default is "Disable".
Allows user to configure the PoE Port Start Up interval time.
Select the ports to apply the Port Sequential function
Figure 4-9-5
PoE delay is to delay power feeding when the
appears.