Panasonic KX-TDA50 Feature Manual page 292

Hide thumbs Also See for KX-TDA50:
Table of Contents

Advertisement

16.1.1 SMDR (Station Message Detail Recording)
e.
Stop Bit Length: Stop bit indicates the end of a bit string which composes a character. Select an
appropriate value depending on the requirements of the PC or printer.
13.1 [11-1] Main—RS-232C—
[800] RS-232C Parameter—Stop Bit Length
If a call is transferred to an ICD group using Automatic Transfer, the condition code "TR" will not be recorded
on SMDR (® 3.1.8 Call Transfer).
[Host PBX Access Code]
The dialed number including the Host PBX Access code will be recorded on SMDR only if the modified
number setting is selected in the ARS setting for SMDR.
When a Host PBX Access code is assigned to a trunk group, calls to extensions of the host PBX are not
recorded on SMDR.
A Host PBX Access Code can be used to record only long distance calls on SMDR when a CO line port is
connected directly to the telephone company (not a host PBX). This is allowed when the long distance
code (e.g., "0") is assigned as the Host PBX Access code. All local calls (e.g., calls that do not require a
"0" to be dialed first) are treated as extensions of the telephone company and do not get recorded on
SMDR, because in this case this PBX recognizes the telephone company as the host PBX. Therefore, only
long distance calls are recorded on SMDR.
Installation Manual References
KX-TDA50
2.8.1 Connection of Peripherals
KX-TDA100/KX-TDA200
2.11.1 Connection of Peripherals
KX-TDA600
2.3.2 EMEC Card (KX-TDA6105)
2.13.1 Connection of Peripherals
PC Programming Manual References
4.4 [2-3] Timers & Counters—Dial / IRNA / Recall / Tone—
4.11 [2-7-1] Class of Service—COS Settings—CO & SMDR—
8.2 [6-2] Hotel—Main—
13.1 [11-1] Main
→SMDR
→SMDR Options
→RS-232C—
Communication—Baud Rate
→RS-232C—
Communication—NL Code
→RS-232C—
Communication—Word Length
→RS-232C—
Communication—Parity Bit
→RS-232C—
Communication—Stop Bit
PT Programming Manual References
[800] RS-232C Parameter—New Line Code
[800] RS-232C Parameter—Baud Rate
[800] RS-232C Parameter—Word Length
[800] RS-232C Parameter—Parity Bit
[800] RS-232C Parameter—Stop Bit Length
[802] SMDR Page Length
[803] SMDR Skip Perforation
[804] SMDR Outgoing Call Printing
292
Feature Manual
Communication—Stop Bit
SMDR for External Hotel Application 2—Printing Message 1–8
Dial—Analog CO Call Duration Start
Outgoing CO Call Printout (SMDR)
Document Version 2010-11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tda600Kx-tda100Kx-tda200

Table of Contents