Removing And Installing Panels - Lennox XP17-024-230-01 Installation And Service Procedure

Table of Contents

Advertisement

Removing and Installing Panels

PANELS
ACCESS AND LOUVERED
WARNING
To prevent personal injury, or damage to panels, unit or structure, be sure to ob­
serve the following:
While installing or servicing this unit, carefully stow all removed panels out of the
way, so that the panels will not cause injury to personnel, nor cause damage to
objects or structures nearby, nor will the panels be subjected to damage (e.g., be­
ing bent or scratched).
While handling or stowing the panels, consider any weather conditions, especially
windy conditions, that may cause panels to be blown around and battered.
IMPORTANT — Do not allow panels to hang on unit by top tab. Tab is for align­
ment and not designed to support weight of panel.
PANEL SHOWN SLIGHTLY ROTATED TO ALLOW TOP TAB TO EXIT (OR ENTER) TOP SLOT
FOR REMOVING (OR INSTALLING) PANEL.
LOUVERED PANEL REMOVAL
Remove the louvered panels as follows:
1. Remove two screws, allowing the panel to swing open slightly.
2. Hold the panel firmly throughout this procedure. Rotate bottom corner of panel
away from hinged corner post until lower three tabs clear the slots as illustrated
in detail B.
3. Move panel down until lip of upper tab clears the top slot in corner post as illus­
trated in detail A.
LOUVERED PANEL INSTALLATION
Position the panel almost parallel with the unit as illustrated in detail D with the screw
side as close to the unit as possible. Then, in a continuous motion:
1. Slightly rotate and guide the lip of top tab inward as illustrated in detail A and C;
then upward into the top slot of the hinge corner post.
2. Rotate panel to vertical to fully engage all tabs.
3. Holding the panel's hinged side firmly in place, close the right-hand side of the
panel, aligning the screw holes.
4. When panel is correctly positioned and aligned, insert the screws and tighten.
Detail C
MAINTAIN MINIMUM PANEL ANGLE (AS CLOSE TO PARALLEL
WITH THE UNIT AS POSSIBLE) WHILE INSTALLING PANEL.
IMPORTANT — To help stabilize an outdoor unit, some installations may require
strapping the unit to the pad using brackets and anchors commonly available in the
marketplace.
XP17
ACCESS PANEL REMOVAL
Removal and reinstallation of the ac­
cess panel is as illustrated.
Figure 37. Removing and Installing Panels
Page 60
Detail A
LIP
SCREW
HOLES
Detail B
ROTATE IN THIS DIRECTION; THEN
DOWN TO REMOVE PANEL
Detail D
ANGLE MAY BE
TOO EXTREME
PREFERRED
ANGLE FOR
INSTALLATION
REMOVE 4 SCREWS TO
REMOVE PANEL FOR
ACCESSING COMPRESSOR
AND CONTROLS.
POSITION PANEL WITH HOLES
ALIGNED; INSTALL SCREWS
AND TIGHTEN.
HOLD DOOR FIRMLY ALONG
THE HINGED SIDE TO MAINTAIN
FULLY-ENGAGED TABS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents