Lennox XP17-024-230-01 Installation And Service Procedure page 39

Table of Contents

Advertisement

Sound Reduction (SR1) Cover
DISASSEMBLY PROCEDURE
The illustration to the right identifies the sound reduction
parts. Disassembly procedure is as follows:
4. Remove top, middle and bottom cable ties.
5. Remove top caps.
6. Remove SR1 left and right side covers.
7. Remove suction grommet.
8. Remove discharge grommet.
ASSEMBLY PROCEDURE
The illustration to the right identifies the sound reduction
parts. Assembly procedure is as follows:
1. Remove discharge grommet.
2. Install suction grommet.
3. Install SR1 left and right side covers.
4. Fasten new bottom cable tie.
5. Install discharge grommet.
6. Install top caps.
7. Fasten new top cable tie.
8. Fasten new middle cable tie.
Figure 17. Sound Reduction Cover Parts and Disassembly (Used on Some Models)
XP17
LEFT TOP CAP
LEFT SIDE
COVER
BOTTOM CABLE TIE
Cable ties are not reusable. Order Cable Tie Kit, Lennox Catalog Number
17W77. Kit will included the following three cable ties:
1. Top and middle cable tie are 36 inches in circumference.
2. Bottom cable tie is 60 inches in circumference.
Gun setting for cable ties should be set to 6 @ 70 PSI. Tension is approximately
51 pounds force.
Page 39
TOP CABLE TIE
MIDDLE CABLE TIE
SUCTION
GROMMET
BASE
RIGHT TOP
CAP
RIGHT SIDE
COVER
DISCHARGE
GROMMET