Jumpers And Links (103369-03) - Lennox XP17-024-230-01 Installation And Service Procedure

Table of Contents

Advertisement

Jumper and Links (103369-03)
J4 - COMPRESSOR
SHIFT DELAY
30
SECOND DELAY
(DEFAULT)
30
0
SECOND DELAY
J2 - SECOND-STAGE
LOCK-IN
TEMPERATURE
(TWO-STAGE HEAT PUMP ONLY)
55
DEGREE
TARGET
50
DEGREE
TARGET
45
DEGREE
TARGET
40
DEGREE
TARGET (DEFAULT)
Figure 15. Jumpers and Links (Outdoor Control Part Number 103369-03)
XP17
7-SEGMENT DISPLAY
0
SECOND-STAGE LOCK-IN
TEMPERATURE
J3 - DEFROST AUTO
PUSH BUTTON
J1 - DEFROST TERMINATION
TEMPERATURE
TARGET
DEGREE
TARGET
DEGREE
TARGET
DS TO R LINK - EDA APPLICATION
(TWO-STAGE UNIT ONLY)
CUT FOR HUMIDITROL
DEHUMIFICATION ACCESSORY (EDA)
APPLICATIONS.
NOTE - LINK NOT APPLICABLE TO SINGLE-STAGE
UNIT. CUTTING LINK WILL HAVE NO AFFECT ON
OPERATION OF SINGLE-STAGE UNITS
Page 27
(HEAT PUMP ONLY)
JUMPER ON PINS 1 AND 2
DEFROST AUTO ENABLED
JUMPER ON PINS 2 AND 3
DEFROST AUTO DISABLED (DEFAULT)
(HEAT PUMP ONLY)
MAX
(DEFAULT WHEN JUMPER IS
90
REMOVED OR MISSING)
50
DEGREE
70
TARGET
(DEFAULT)
®
- ENHANCED
ON
OFF
90
.

Hide quick links: