Option
Range
Set the linear range.
Valid:1 – 6
Default:3
A value of 1 specifies that the linear range that is searched for a readable label is a tight vertical range near the
aimer. A value of 6 specifies that the entire height of the image is to be searched.
AIM
Duration of the imager aim beam in 0.1 second increments.
Valid:0 – 50 (0 to 5 seconds)
Default:0
Lights
Specifies if the imager's lights and aimer should be left on during the entire decode process.
The default is disabled.
If disabled, the lights are turned on only during image capture, then turned off while the imager attempts to proc-
ess and decode the bar code.
If enabled, the aimer and lights remain turned on during the entire process.
In Aggressive Linear Decode mode, set this parameter to enabled to improve the aimer visibility. See "Mode"
above.