Main Tab - Honeywell MX8 Reference Manual

Hide thumbs Also See for MX8:
Table of Contents

Advertisement

Main Tab

Start > Settings > System > Data Collection > Main tab
Factory Default Settings
Device 1
Device 2
Device 3
Keep Awake
Send Key Messages
Scan Mode - Continuous
Scan Mode - Timeout between same symbol
Device 1 – Internal. Radio button allows scanner input/output on Device 1 (scan key or trigger).
Device 2 – Output is enabled when COM1 is enabled on this port.
Device 3 – Output is enabled when COM1 is enabled on this port.
The Data Collection Wedge supports up to three concurrent data collection devices. For example, the internal scanner could be
used to collect data at the same time a Bluetooth scanner is paired and/or a serial device is attached to COM1 (the MX8 must
be in a desktop cradle to use a tethered scanner).
Note:
Since Internal is the default setting for Device 2, a Bluetooth scanner can be paired with the Wedge using EZPair on
Device 1 without disabling the internal scanner.
Device with integrated Symbol Scanner
Note:
The Scan Mode (Continuous Scan) section is only present if the MX8 is equipped with a Symbol integrated scanner.
Adjust the settings and tap ok to save the changes. The changes take effect immediately.
5-4
Disabled
Internal
Disabled
Disabled
Enabled
Disabled
1 second
Device with any other imager/scanner