Observe These Instructions For Space Heating Water; Tools, Materials And Additional Equipment; Disposal - Buderus logamax plus gb142-24 Installation Manual

Hide thumbs Also See for logamax plus gb142-24:
Table of Contents

Advertisement

1
Safety and general instructions
– If you find any defects, you must inform the owner of the
system of the defect and the associated hazard in
writing.
DANGER
if flammable gas explodes.
Beware if you smell gas: there may be an
explosion hazard!
Warning: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury or death.
Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other boiler.
What to do if you smell gas
Do not try to light any boiler.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Buderus • http://www.buderus.net
6
1.4
Observe these instructions for space
heating water
Unsuitable heating system water can promote the forma-
tion of scale or sludge, which affects system efficiency.
It can also cause corrosion and reduce life of the heat
exchanger.
– You must follow Buderus guidelines for boiler water
quality.
– Thoroughly flush the system prior to filling.
– Use of a Buderus approved boiler cleaner is
recommended.
– Never use salt bedding exchangers to soften the water.
– Do not use inhibitors or other additives unless approved
by Buderus for that purpose!
– When frost protection of the heating system is desired,
only use Buderus-approved Aluminum-safe antifreeze.
– When using oxygen-permeable pipes, e. g. for floor
heating systems, you must separate the system using
heat exchangers.
– The maximum permissible flow rate of the
GB142-24/30 this is 11 GPM (gal./min.)(= 42 l/min.), for
the GB142-45 is 15 GPM (= 57 l/min.) and for the
GB142-60 is 20 GPM (= 76 l/min.).
1.5
Tools, materials and additional
equipment
For the installation and maintenance of the boiler you will
need the standard tools for space heating, gas and water
fitting.
In addition, a handtruck with a fastening belt is useful.
1.6

Disposal

– Dispose of the boiler packaging in an environmentally
sound manner.
– Dispose of components of the heating system (e. g.
boiler or control device), that must be replaced in an
environmentally responsible manner.
We reserve the right to make any changes due to technical modifications!
Installation instructions Logamax plus GB142-24/30/45/60 • version 10/2007

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents