The orifice change is accomplished by:
1.
Turning the gas off at the shut-off valve
2.
Removing the range from the cabinets
3.
Remove the back guard from the range
4.
Locating the gas supply line at the end of the broiler venturi
5.
Remove and replace the orifice spud located at the end of the gas supply tube
6.
Reverse steps 3-2-1
7.
Check the operation of the infrared broiler