Rangetop Cutout And Specifications - Viking VGR30 Service Manual

Free standing gas range
Table of Contents

Advertisement

1.
Gas Line Requirements:
a. Gas pipe size should be 3/4" (½" inside diameter)
b. Gas pipe should be 3" or less from floor and 6" from left to center of unit to allow for the
flex line.
i.e.
If it is higher than 3" from the floor, the range will not fit flush against the wall and
The shutoff valve will not be accessible.
2.
Electrical Requirements: Gas ranges, gas rangetops, and Gas cooktops require a 120 volt
electrical outlet (GFI ground fault outlet not recommended).
a. 3" or less from the floor and 6" from the right to center of the unit.
i.e.

RANGETOP CUTOUT and SPECIFICATIONS

30" range
6"-15" from left
36" range
6"-15" from left
30" range
6"-15" from right
36" range
6"-18" from right
48" range
60" range
48" range
60" range
9
6"-24" from left
6"-30" from left
6"-24" from right
6"-30" from right