Pressure Relief Procedure - Graco Mark X Operation Manual

Electric airless sprayers
Hide thumbs Also See for Mark X:
Table of Contents

Advertisement

Pressure Relief Procedure

This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing fluid
and moving parts, follow the Pressure Relief Proce-
dure when you stop spraying and before cleaning,
checking, or servicing the equipment.
1. Turn power OFF. Wait 7 seconds for power to
dissipate.
ti4265a
2. Lock gun trigger safety.
ti18199a
3. Remove guard and SwitchTip.
ti2769a
3A2575A
4. Turn pressure to lowest setting. Trigger gun to
relieve pressure.
5. Put drain tube in pail. Turn prime valve down to
DRAIN position.
ti2595a
Pressure Relief Procedure
ti7506b
9