Grounding

Pails

Solvent and oil/based fluids: follow local code. Use
only conductive metal pails, placed on a grounded sur-
face such as concrete.
Do not place pail on a nonconductive surface such as
paper or cardboard which interrupts grounding continu-
ity.
Grounding a metal pail: connect a ground wire to the
pail by clamping one end to pail and other end to a true
earth ground.
ti14840a
8
ti5850b
To maintain grounding continuity when flushing or
relieving pressure: hold metal part of spray gun firmly
to side of a grounded metal pail. Then trigger gun.