Operation
Mark X Electric Airless Sprayers
For Portable Airless Spraying of Architectural Coatings and Paints.
For professional use only.
3300 psi (227 bar, 22.7 MPa) Maximum Working Pressure
IMPORTANT SAFETY INSTRUCTIONS
Read all warnings and instructions in this
manual and all related manuals. Save
these instructions.
Related Manuals:
3A2576
3A2577
310894
Mark X
3A2575A
ti18818a
EN

Advertisement

Table of Contents
loading

Summary of Contents for Graco Mark X

  • Page 1 Operation 3A2575A Mark X Electric Airless Sprayers For Portable Airless Spraying of Architectural Coatings and Paints. For professional use only. 3300 psi (227 bar, 22.7 MPa) Maximum Working Pressure IMPORTANT SAFETY INSTRUCTIONS Read all warnings and instructions in this manual and all related manuals. Save these instructions.
  • Page 2: Table Of Contents

    Notes ........19 Graco Standard Warranty ....20...
  • Page 3: Warnings

    Warnings Warnings The following warnings are for the setup, use, grounding, maintenance and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risks. When these symbols appear in the body of this manual, refer back to these Warnings. Product-specific hazard symbols and warn- ings not covered in this section may appear throughout the body of this manual where applicable.
  • Page 4 Check hoses and parts for signs of damage. Replace any damaged hoses or parts. • This system is capable of producing 3300 psi (227 bar, 22.7 MPa). Use Graco replacement parts or accessories that are rated a minimum of 3300 psi (227 bar, 22.7 MPa).
  • Page 5 Warnings WARNING EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals.
  • Page 6: Component Identification

    Component Identification Component Identification ti18819a Digital Display Pump ON/OFF Switch Gun/Trigger Lock Pressure Control ™ Bearing Housing / ProConnect Spray / Prime Drain Tube Filter Unit / Serial Tag 3A2575A...
  • Page 7: Grounding

    L6-30) installed to local codes and ordinances. Never use an outlet that is not grounded. • Mark X 240 Volt is manufactured with a 3-wire plug to be connected to a 3-wire receptacle • Mark X 240 Volt can be connected to a 4-wire...
  • Page 8: Pails

    Grounding Pails To maintain grounding continuity when flushing or relieving pressure: hold metal part of spray gun firmly to side of a grounded metal pail. Then trigger gun. Solvent and oil/based fluids: follow local code. Use only conductive metal pails, placed on a grounded sur- face such as concrete.
  • Page 9: Pressure Relief Procedure

    Pressure Relief Procedure Pressure Relief Procedure 4. Turn pressure to lowest setting. Trigger gun to relieve pressure. This equipment stays pressurized until pressure is manually relieved. To help prevent serious injury from pressurized fluid, such as skin injection, splashing fluid and moving parts, follow the Pressure Relief Proce- dure when you stop spraying and before cleaning, checking, or servicing the equipment.
  • Page 10: Setup

    2. Optional: Install adapter and 11 ft 10 in. whip hose to other end of 50 ft airless hose. ti17608a 8. Fill throat packing nut with Graco TSL to prevent ti7539b premature packing wear. Do this each time you spray.
  • Page 11 Setup 9. Turn power OFF. 12. Place pump in grounded metal pail partially filled with flushing fluid. Attach ground wire to pail and to true earth ground. Perform steps 1 - 5 of Startup to ti4265a flush out storage oil shipped in sprayer. Use water to flush water-base paint and mineral spirits to flush oil-base paint and storage oil.
  • Page 12: Startup

    Startup Startup 5. Hold gun against grounded metal flushing pail. Trig- ger gun and increase fluid pressure 1/2 turn. Flush 1 minute. 1. Turn pressure control to lowest pressure. ti4271a ti4271a 6. Inspect for leaks. Do not stop leaks with hand or a rag! If leaks occur, perform Pressure Relief Proce- dure, page 9.
  • Page 13: Switch Tip Installation

    Switch Tip Installation Switch Tip Installation 2. Hold gun perpendicular, 10-12 in. (25-30 cm) from surface. Spray back and forth. Overlap by 50%. Trig- ger gun after moving and release before stopping. ™ 1. Use spray tip (A) to insert OneSeal (B) into guard (C).
  • Page 14: Digital Tracking System

    Digital Tracking System Digital Tracking System Job Gallons 1. Short press DTS button to move to Job Gallons (or liters x 10). Operation Main Menu Short press to move to next display. Press and hold (5 seconds) to change units or reset data. ti13612a ti13620a ti13610b...
  • Page 15: Secondary Menu - Stored Data

    Pressure in the sprayer has spiked. Typical causes of played. this are using a small diameter hose, using a short hose, or using a non-Graco hose (Graco hoses are designed to absorb pressure spikes). Code 04: ti13619b ti13618a The sprayer has detected incoming voltage surges.
  • Page 16: Cleanup

    Cleanup Cleanup 5. Turn prime valve down to DRAIN position and allow flushing fluid to circulate until flushing fluid appears clear. 1. Perform Pressure Relief Procedure (page 9), steps 1 - 4. Remove tip guard from gun. NOTE: Use water for water-base material, mineral spir- its for oil-base material, or other solvents recommended by manufacturer.
  • Page 17 Cleanup 9. Remove filters from gun and sprayer, if installed. 11. Wipe sprayer, hose and gun with a rag soaked in Clean and inspect. Install filters. water or mineral spirits. ti2776a ti13454a 10. If flushing with water, flush again with mineral spirits, or Pump Armor, to leave a protective coating to pre- vent freezing or corrosion.
  • Page 18: Technical Data

    Maximum Delivery Maximum Tip Model 240V, A, Hz Motor HP (KW) Minimum W gallon (liter) gpm (lpm) Size Mark X 16A, 60 5000 4.0 (3.0) 70 (19) 2.2 (8.3) 0.045 Basic Sprayer Wetted Parts......Noise Level zinc- and nickel-plated carbon steel, nylon, stainless Sound power ..........91 dBa*...
  • Page 19: Notes

    Notes Notes 3A2575A...
  • Page 20: Graco Standard Warranty

    With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.