Panasonic UF-580 Service Manual page 146

Hide thumbs Also See for UF-580:
Table of Contents

Advertisement

No.
Parameter
090 PRINT DENSITY 1 = Normal
091 Not Used
092 SMOOTHING
093
Not Used
~
129
130 BUSY-ACK
TIMING
(Except UF-580/
780)
131 CMD RCV GRD
TIMER
(Except UF-580/
780)
132 PRT DATA
TIMER
(Except UF-580/
780)
133 COLLATION
(PRT)
(Except UF-580/
780)
134 COLLATION
(PC I/F)
(Except UF-580/
780)
135
Not Used
~
199
Note 1: Function Parameter No. 070 (Line Error)-Transmit condition of RTP/PIP or RTN/PIN
Signal
MCF/PIP
RTP/PIP
RTN/PIN
Note 2: Function Parameter No. 071 (Total Error)-Transmit condition of RTP/PIP or RTN/PIN
Note 3: The default setting of parameters depends on the destination's specifications or regulations. Print
the Function Parameter List to confirm the default settings.
Function Parameter Table
Selections
2 = Darker
1 = Off
2 = On
• In Busy
• After Busy
• While Busy
1 min.
~
15 min.
1 min.
~
15 min.
1 = Off
2 = On
3 = Auto
1 = Off
2 = On
3 = Auto
1:128
2:256
0-31
0-63
32-63
64-127
64-127
128-255
Signal
1:5%
MCF/PIP
0-2
RTP/PIP
3-4
RTN/PIN
5-
Print Density sometimes gets light at low Humidity
condition. In this case, selects "2:Darker".
(Except for U.S.A. and Canada)
Selects whether the smoothing function is available.
Selects the signal timing between the BUSY and
ACK signal in Printer Interface Mode.
Selects the Guard Timer between each GDI
Command in Printer Interface Mode.
Selects the Guard Timer between each GDI Data
Frame in Printer Interface Mode.
Selects the Print Collation in Printer Interface Mode.
When "Auto" is selected, print collation will operate
according to the setting in Fax Parameter #65.
Selects the Print Collation in PC Interface Mode.
When "Auto" is selected, print collation will operate
according to the setting in Fax Parameter #65.
Setting
3:512
4:1024
0-127
0-255
128-255
256-511
256-511
512-1023
Setting
2:10%
3:15%
0-4
0-7
5-9
8-14
10-
15-
146
Function
5:2048
6:Off
0-511
Always
512-1023
-
1024-2047
-
4:20%
0-9
10-19
20-

Hide quick links: