Testing Procedures
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven before servicing, unless
testing requires power.
Jenn-Air Matrix
Control Panel Assembly
Relay Logic
Note that this chart was correct at time of printing; subsequent changes to cooking parameters may alter it.
COOKING MODE
IDLE
BAKE PREHEAT
BAKE
BROIL PREHEAT
BROIL
CLEAN PREHEAT
CLEAN
KEEP WARM
DRYING PREHEAT
DRYING
18
!
W ARNING
Continuity is indicated as follows:
1000 – 6600 Ω for Cancel pad
1000 – 15000 Ω for All other pads
16
9
8
1
r
r
16022514 Rev. 0
Pad
Trace
1
13 & 15
2
12 & 15
3
10 & 15
4
7 & 13
5
12 & 13
6
10 & 12
7
4 & 13
8
4 & 12
9
5 & 10
0
5 & 12
Cancel
1 & 2/3
Clock
4 & 14
Cook & Hold
5 & 14
Broil
13 & 14
Bake
7 & 15
Clean
5 & 7
Keep Warm
14 & 15
Favorite
5 & 13
Timer
4 & 5
Oven Light
4 & 10
KEY INDEX
- OFF
- ON
- CYCLING
- ON OR OFF (DETERMINED BY
USER INPUT)
- TEMPERATURE CONTROLLED
© 2004 Maytag Services
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity