Testing Procedures
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven before servicing, unless
testing requires power.
Illustration
Pressure regulator
Ignitor
Gas valve
Shut off valve
Filter capacitor
16
!
Component
Verify gas pressure (WCP).
If on LP service, verify proper gas
supply conversion.
Test for voltage at terminals ...............
Test for the amount of amperage in the
circuit..................................................
(Ignitor may glow, but not have
sufficient amperage to open valve).
Disconnect wiring to valve.
Measure resistance on bake circuit.
Measure resistance on broil circuit.
Check to verify gas supply is turned on
(shown in the OFF position).
16022514 Rev. 0
W ARNING
Test Procedure
Results
4
Natural
"
10
LP/Propane
"
120 VAC
3.2
3.6 Amps.
Continuity
!
WARNING
Do not attempt to open valve with
120 VAC.
Verify valve does not leak.