Exmark Lazer Z XP Operator's Manual page 35

Hide thumbs Also See for Lazer Z XP:
Table of Contents

Advertisement

For Exmark Mower Parts Call 606-678-9623 or 606-561-4983
5.1.12
31 HP DAIHATSU GAS
a) Re-install all drain plugs and hoses and tighten drain cock.
b) Fill radiator with a 50/50 mix of water and Dex-Cool © coolant, allowing
some room (approximately 1/2" (1.27 cm)) for expansion. Add 50/50
coolant mix to overflow bottle on the left side of the engine as required to
bring the level up to the indicator line on the bottle.
POTENTIAL HAZARD
♦ Engine compartment contains open belt drives and fans.
♦ Rotating components can cause injury
WHAT CAN HAPPEN
♦ Fingers, hands, loose clothing or jewelry can get caught
by the rotating fan and drive shaft.
HOW TO AVOID THE HAZARD
♦ Do not operate machine without the covers in place.
♦ Keep fingers, hands, and clothing clear of rotating
components.
♦ Shut off engine, wait for all moving parts to stop, and
remove the ignition key before performing maintenance.
e) With the cap off the radiator, tilt hood closed and put the seat down. Start
the engine. Refer to Section 4.3.2. Return the seat up and hood forward to
the open position.
f) Operate engine until the engine thermostat opens and coolant is circulating
through the radiator core. As air is purged from the engine block and the
coolant level drops, add additional coolant to the radiator.
g) When the radiator is completely full and no additional coolant can be
added, continue running the engine and install the radiator cap. Make sure
that the cap is completely seated by pressing down firmly while turning until
the cap stops. Once the cap is installed, the engine may be stopped.
Check hydraulic oil level:
Service Interval: 40 hr.
a)
Stop engine and wait for all moving parts to stop.
www.mymowerparts.com
27 HP DAIHATSU DIESEL
FIGURE 6
COOLANT PLUG LOCATION
WARNING
- 30 -

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents