Exmark Lazer Z XP Operator's Manual page 19

Hide thumbs Also See for Lazer Z XP:
Table of Contents

Advertisement

For Exmark Mower Parts Call 606-678-9623 or 606-561-4983
3.2.1
3.2.2
3.2.3
Tilt seat up to gain access to the battery.
POTENTIAL HAZARD
♦ Charging the battery may produce explosive gases
WHAT CAN HAPPEN
♦ Battery gases can explode causing serious injury.
HOW TO AVOID THE HAZARD
♦ Keep sparks, flames, or cigarettes away from battery.
♦ Ventilate when charging or using battery in an
enclosed space.
♦ Make sure venting path of battery is always open once
battery is filled with acid.
Check the voltage of the battery with a digital voltmeter. Locate the voltage reading
of the battery in the table below and charge the battery for the recommended time
interval to bring the charge up to a full charge of 12.6 volts or greater.
IMPORTANT: When charging the battery, make sure the negative battery
cables are disconnected and the battery charger has an output of 16 volts and 7
amps or less to avoid damaging the battery (see chart below for recommended
charger settings).
Voltage
Percent
Reading
Charge
12.6 or greater
100%
12.4 – 12.6
75 – 100%
12.2 – 12.4
50 – 75%
12.0 – 12.2
25 – 50%
11.7 – 12.0
0 – 25%
11.7 or less
0%
POTENTIAL HAZARD
♦ If the ignition is in the "ON" position there is potential
for sparks and engagement of components.
WHAT CAN HAPPEN
♦ Sparks could cause an explosion or moving parts
could accidentally engage causing personal injury.
HOW TO AVOID THE HAZARD
♦ Be sure ignition switch is in the "OFF" position before
charging the battery.
Connect the negative battery cables.
NOTE: If the positive cable is also disconnected, connect the positive (red) cable
to the positive terminal on the battery first, then connect the negative (black) cable
to the negative terminal. Slip insulator boot over the positive terminal.
NOTE: If time does not permit charging the battery, or if charging equipment is
not available, connect the negative battery cables and run the vehicle
continuously for 20 to 30 minutes to sufficiently charge the battery.
www.mymowerparts.com
DANGER
Maximum
Charger Settings
16 volts/7 amps
16 volts/7 amps
16 volts/7 amps
14.4 volts/4 amps
14.4 volts/4 amps
14.4 volts/2 amps
CAUTION
- 14 -
Charging Interval
No Charging Required
30 Minutes
1 Hour
2 Hours
3 Hours
6 Hours or More

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents