Installation instructions
2
1
2a

Electrical installation

WARNING!
The receptacle on the rear of the machine is
designed to accommodate ASKO washers
ONLY (rated 208–240 V.) To use this receptacle,
you must use the ready-fitted plug supplied with
the washing machine or an equivalent.
ASKO washers rated 208–240 V have two internal
fuses of 15 A each.
The machine should only be connected to a
grounded wall socket.
WARNING!
This appliance must be properly grounded.
Refer to the "Important Safety Instructions" for
grounding instructions.
The power supply cord must be grounded. If the
machine is to be used in a wet area, the supply
must be protected by a residual current device.
Connection to a permanently wired supply point
must be made only by a qualified electrician. As
supplied: Single-phase, 230 V, 60 Hz, 2500W
heater rating 30 A circuit required.
Remove cover to
access terminal box.
(Requires a 20-Torx
screwdriver.)
22
Electrical Connections
Maximum
WARNING!
height 40"
Read the Electrical requirements and grounding
instructions before connecting the tumble dryer.
Electric models of the dryer are manufactured for
a 3-wire connection system. The dryer frame is
grounded by a link to the neutral conductor on the
dryer terminal block. If local codes do not permit
grounding through the neutral, the grounding link
from the terminal block must be removed and a
separate ground wire must be used.
Only a 4-conductor cord shall be used when
the appliance is installed in a location where
grounding through the neutral conductor is
prohibited. Grounding through the neutral
conductor is prohibited for new branch-circuit
installations,
vehicles, and areas where local codes prohibit
grounding through the neutral conductors. The
grounding link on the dryer must be removed for
all 4-wire installations.
These Electrical Connection instructions provide
for installing the dryer in the following situations:
3-wire connection where local codes permit
grounding through the neutral. 3-wire connection
plus separate grounding connector where local
codes do not permit grounding through the
neutral.
4-wire connection.
Each of the above connections can be made
with an approved power supply cord or by direct
wiring. Each connection instruction identifies
the appropriate Power Supply Cord and covers
requirements for direct wiring.
NOTE!
In Canada, the dryer is delivered ready-fitted with
a four-prong plug intended for connection to a
single-phase supply.
Customer Care Center
1-800-898-1879
www.askona.com