Bosch DCN Next Generation Installation And Operation Manual page 183

Hide thumbs Also See for DCN Next Generation:
Table of Contents

Advertisement

Conference System
IP address
Use the menu items in the 8I IP Address sub-menu to set the IP address.
Menu item
8Ia Address
8Ib Subnet Mask
8Ic Def. Gateway
Table 7.11 IP Address sub-menu (* = default)
CCU mode
Use the 8J CCU Mode sub-menu item to set the mode of the central control unit.
Menu item
8J CCU Mode
Table 7.12 CCU Mode sub-menu (* = default)
NOTICE!
For DCN-CCUB2, the 8J CCU mode is not selectable.
To configure a multi CCU system:
1.
2.
3.
4.
5.
Bosch Security Systems B.V.
Value
192.168.0.100 *
255.255.255.0 *
0.0.0.0 *
Parameter
Mode:
Standalone*
Single
Multi
Use Standalone for systems with only one DCN-CCU2.
Use Single mode if one of the DCN-CCU2's needs to be (temporarily) isolated from the
optical network.
Use Multi mode for a multi-CCU system with more then two DCN-CCU2's.
Power-up all CCUs without connections to the optical network and without connection to
other CCUs via Ethernet.
Use menu 7Ac and 7Ad to verify that all CCUs have the same FPGA and firmware Version.
If not, use the Download & Licensing Tool to upgrade all CCUs to the same version.
Use menu 8J to select for all CCUs in the multi CCU system the same System-ID between
00-15 (default: 00).
Each CCU also needs an individual Slave-ID. Use menu 8J to give each slave CCU a unique
Slave-ID from 01 - 30. Slave-ID 01 is reserved for the Master-CCU (default: 01).
Use menu 8I to give each CCU a unique IP-address.
a.
In case a network with DHCP support (Dynamic Host Configuration Protocol) is
used, select 'DHCP'and ignore steps 5b thru 5 d and continue with step 6. Note that
some DHCP servers automatically handout new IP-addresses from time to time. This
is not preferred for a multi-CCU system; renewing the CCU IP-addresses will cause
temporary disconnections between CCUs and cause improper system behavior. With
the enquiry menu 7Af, the current IP Address of a CCU can be found.
b.
In case DHCP is not available, use menu 8Ia to give each CCU within the same
subnet a unique Static IP-address between: 1.0.0.0 – 223.255.255.255 excluding
127.***.***.***. Default: 192.168.0.100.). As a good example, the master CCU can
use the default IP-address; the first slave can use 192.168.0.101, the second
192.168.0.102 and so fort.
c.
Use menu 8Ib to give each CCU the same TCP/IP subnet mask between 0.0.0.0 -
255.255.255.255. Default: 255.255.255.0.
Installation and Operation manual
Description
Sets the TCP/IP address.
Sets the TCP/IP subnet mask.
Sets the TCP/IP default gateway.
Value
Description
Multi CCU slave
Sets the CCU to standalone,
ID, 01* to 30
single or multi mode.
Configuration | en 183