104 en | Installation
5.6

DCN-Flush mounted products

Snap-mounting
Use the snap-mounting method to install flush-mounted devices in panels with a thickness of
2 mm. The snap-mounting method uses the click-to-fit mechanism of the flush-mounted
devices. 'Click' the flush-mounted devices in the recess.
Figure 5.18 Click-to-fit mechanism
Refer to the figure for the dimensions of a recess for the snap-mounting method.
Figure 5.19 Recess, snap-mounting method
The length (x) of a recess depends on the number-size factor (NSF) of the flush-mounted
device that must be installed in the recess. To get the length of a recess:
Total NSF
1
2
Table 5.1 Lengths, snap-mounting method
DCN-NG_IOM_V4.1 | V1.3 | 2012.07
Get the number-size factor (NSF) of the flush-mounted device from Table 5.3.
Use the NSF to get the length (x) of the recess from the table.
x (mm)
38.2
88.2