Messages in the display

Message
Open bottom right
grille, clean the heat
exchanger
Clean the lint filter
and rinse the plinth
filter.
Filter in base not
fitted. Please fit it.
Power outage.
Program stopped
Finish/Cooling down
68
Possible cause and solution
The heat exchanger's cooling fins behind the grille
can become blocked with dust and dirt drawn in from
the surrounding area and the airways can become
blocked with lint.
 Clean the heat exchanger. See "Bottom right grille/
heat exchanger" in "Cleaning and care".
 Check and clean the filters in the loading area and
in the plinth.
 To delete the message: touch the
button.
This information is displayed at the end of the
program if the tumble dryer is not working correctly
or economically.
The lint filters may be clogged.
 Normally, all you have to do is clean the lint filters.
 Also check the plinth filter and clean it if
necessary.
 If you have removed the plinth filter, also check the
filter insert behind it. Clean the filter insert if
necessary.
Please see "Cleaning and care" for cleaning
instructions.
 To delete the message: touch the
button.
The plinth filter has not been inserted.
 Check the filter (in the plinth).
Removing the filter during a drying program will
result in the program being cancelled.
There has been a power outage.
 When power is restored, confirm with
 Touch the Start/Stop sensor button.
There is no fault, but the drying process continues.
The laundry is still being cooled. The program is just
about to end.
 You can remove the laundry and spread it out to
cool down or leave it in the tumble dryer to cool
down until the end of the program.
 sensor
OK
 sensor
OK