1-4-3 Cable
⿎ Controller Power Cable
Attached controller power cable varies depending on each model. Please select a cable compliant with the standards in the
country or region where it is used.
Rating 125V, CSA/UL and PSE standards compatible cable (North America, Japan) : Attached to LP-4xx(T)U /
q
LP-4xx(T)U-A / LP-VxxU / LP-VxxU-A / LP-W type
Rating 250V, VDE standards compatible cable (Europe) : Attached to LP-4xx(T)U-C / LP-VxxU-C
w
Rating 250V, CCC standards compatible cable (China) : Attached to LP-4xx(T)U-CHN / LP-VxxU-CHN type
e
Unit: mm
Minimum bending radius 50mm
q
⿎ Head Power Cable
Unit: mm
Minimum bending radius 100mm
⿎ Head Control Cable
Unit: mm
Minimum bending radius 100mm
17
50
5000
5000
51
ME-LP400V-OP-6
3000±50
w
+200
0
+200
0
e
45