Maintenance Items
Listed below are typical parts that require cleaning or replacement depending on the usage environment or duration of
service of the laser marker. Some parts are maintainable by the customer, and other parts are required to be repaired or
replaced by our service representative, depending on the types of parts and the defects.
For purchasing replacement parts or requesting our service representative to repair or replace parts, contact our sales
agency.
LP-400 Series
e
y
ui
q
Head (Tower Model)
LP-V/LP-W Series
ert
No.
Parts name
Laser emission port (fθ lens)
q
Protection glass of the laser
w
emission port *1
Intake/exhaust vent
e
Air filter
r
Air-cooling fan
t
Laser oscillator
y
Galvano scanner
u
Internal shutter
i
Battery inside the controller
o
Fuse
1)
Cable
1!
*1 : The protection glass of the laser emission port is available only for LP-V/LP-W series.
y
ert
ui
e
q
Head (Standard Model)
ui
qw
Head
Main cause for
degradation
Contamination
Contamination
Contamination
Contamination
Contamination
Aging
Aging
Aging
Aging
Blown
Broken
ME-LP400V-OP-6
e
ert
er
er
Controller
Daily maintenance
Replacement when degraded or defective
Cleaning
Replacement at our service department
Cleaning
Customer-replaceable
Cleaning
―
Cleaning
Customer-replaceable
―
Replacement at our service department
Check output
Replacement at our service department
―
Replacement at our service department
―
Replacement at our service department
―
Replacement at our service department
―
Customer-replaceable
―
Customer-replaceable
et1)
o
Controller
et1)
o
y
273