Sign In
Upload
Manuals
Brands
Zeta Manuals
Fire Alarms
INFINITY ID2
Zeta INFINITY ID2 Manuals
Manuals and User Guides for Zeta INFINITY ID2. We have
4
Zeta INFINITY ID2 manuals available for free PDF download: Installation Manual, User Manual, Maintenance Manual & Log Book, User Manual
Zeta INFINITY ID2 Installation Manual (45 pages)
INTELLIGENT 2 WIRE FIRE DETECTION SYSTEM WITH 'ID' TECHNOLOGY
Brand:
Zeta
| Category:
Fire Alarms
| Size: 3.67 MB
Table of Contents
Table of Contents
2
Safety Information
4
Installation Information
4
Safety Precautions During Normal Operation of Panel
4
Battery Information
4
Product Disposal at the End of Its Working Life
4
Product Design Information
5
Fire Alarm Control Section
5
Power Supply Section
5
Environmental
5
Panel Description & Design Concept
6
Using this Manual
7
Equipment Guarantee
7
Designing a System
8
Designing a ID2 System
8
Installing the System
9
Considerations before Installation
9
Mounting the Control Panel
9
Recommended Cable Types and Their Limitations
9
Mains Wiring Recommendations
9
First Fix
10
Mounting the Fire Alarm Panel
10
Fixing the Back Box to the Wall
10
Planning Cable Entry
10
Connecting the Mains Power
11
Connecting the Batteries
12
Zone Wiring
13
Specific Device Wiring Instructions
14
CP3/AD Manual Call Point
14
MKII Detectors (All Types) Base Connection
14
ZAI - MI Input Module
15
ZAIO - MI Input/Output Module
15
ZASC - MI Sounder Control Module
16
ZAZM - MI Conventional Zone Module
16
Xtratone Sounder/Sounder Flasher
17
Sandwich Sounder
17
Addressable Remote LED Indicator
18
Setting the Device Zone & ID (Detectors, Call Points & Sounders)
19
Loop Mode - Maximum Loop Length Recommendations
21
Sounders
22
Auxiliary Outputs
22
Auxiliary Output Wiring
22
Field Device Termination
23
Terminating the Wiring
23
Other Connections
24
Repeater Connection
24
Configuring the Id2 Fire Alarm Panel
25
Configuring the Zones
25
From a Blank Infinity Id2 Panel
25
From a Previously Configured Panel
25
Verifying the Zone Configuration
25
Labelling the Panel and Zones
26
Labelling the Devices
26
Setting Time and Date
26
Changing the Alarm Tones - Sounders
26
Changing Fire Relay Response
26
Changing Input/Output Interface Response
26
Default Setting
26
Setting Individual I/O Unit Operation - Relay
27
Setting Individual I/O Unit Operation - Input
27
I/O Unit Operation - Panel Link
27
Configuring Alarm Output Resound Operation
28
Setting the LCD Language
28
Software Versions
28
Alarm Verification
29
Alarm Verification Options
29
How Alarm Verification Works
29
Setting the Alarm Verification Delay
29
Applying Alarm Verification Delay to a Detector
29
Restoring the Panels Default Settings
30
Viewing Panel Information
31
Menu Structure
31
Viewing Device Status
32
Locating a Device
32
Using the Event Log
33
The Fire Alarm Condition
34
Viewing a Fire Alarm Event
34
Viewing Faults During a Fire Alarm Condition
34
Viewing Zone Disablements During a Fire Alarm Condition
34
Viewing Device Disablements During a Fire Alarm Condition
34
Viewing Zones in Test Mode During a Fire Alarm Condition
34
Disablement
35
Zone Disablement
35
To Programme Zone (or Sounders) as Disabled
35
Device Disablement
36
Viewing Disablements
36
Viewing Disabled Zones
36
Viewing Disabled Devices
36
Test Mode
37
Why Use Test Mode
37
To Programme Zone in Test Mode
37
To Program Sounder Circuits in Test Mode
37
General Fault Finding
38
Common Fault
38
Zone Contents Fault Finding
38
Zone Faults
38
Supply Faults
39
Earth Faults
39
Double Address
39
System Fault
40
Standby Battery Calculation
41
Device Values for Battery Calculation
41
Example Battery Calculation
42
Pcb Termination Connections
43
Specifications
44
Enclosure Specifications
44
Electrical Specifications
44
Advertisement
Zeta INFINITY ID2 Installation Manual (45 pages)
INTELLIGENT 2 WIRE FIRE DETECTION SYSTEM WITH 'ID' TECHNOLOGY
Brand:
Zeta
| Category:
Fire Alarms
| Size: 3.64 MB
Table of Contents
Table of Contents
2
Safety Information
4
Installation Information
4
Safety Precautions During Normal Operation of Panel
4
Battery Information
4
Product Disposal at the End of Its Working Life
4
Product Design Information
5
Fire Alarm Control Section
5
Power Supply Section
5
Environmental
5
Panel Description & Design Concept
6
Using this Manual
7
Equipment Guarantee
7
Designing a System
8
Designing a ID2 System
8
Installing the System
9
Considerations before Installation
9
Mounting the Control Panel
9
Recommended Cable Types and Their Limitations
9
Mains Wiring Recommendations
9
First Fix
10
Mounting the Fire Alarm Panel
10
Fixing the Back Box to the Wall
10
Planning Cable Entry
10
Connecting the Mains Power
11
Connecting the Batteries
12
Zone Wiring
13
Specific Device Wiring Instructions
14
CP3/AD Manual Call Point
14
MKII Detectors (All Types) Base Connection
14
ZAI - MI Input Module
15
ZAIO - MI Input/Output Module
15
ZASC - MI Sounder Control Module
16
ZAZM - MI Conventional Zone Module
16
Xtratone Sounder/Sounder Flasher
17
Sandwich Sounder
17
Addressable Remote LED Indicator
18
Setting the Device Zone & ID (Detectors, Call Points & Sounders)
19
Loop Mode - Maximum Loop Length Recommendations
21
Sounders
22
Auxiliary Outputs
22
Auxiliary Output Wiring
22
Field Device Termination
23
Terminating the Wiring
23
Other Connections
24
Repeater Connection
24
Configuring the Id2 Fire Alarm Panel
25
Configuring the Zones
25
From a Blank Infinity Id2 Panel
25
From a Previously Configured Panel
25
Verifying the Zone Configuration
25
Labelling the Panel and Zones
26
Labelling the Devices
26
Setting Time and Date
26
Changing the Alarm Tones - Sounders
26
Changing Fire Relay Response
26
Changing Input/Output Interface Response
26
Default Setting
26
Setting Individual I/O Unit Operation - Relay
27
Setting Individual I/O Unit Operation - Input
27
I/O Unit Operation - Panel Link
27
Configuring Alarm Output Resound Operation
28
Setting the LCD Language
28
Software Versions
28
Alarm Verification
29
Alarm Verification Options
29
How Alarm Verification Works
29
Setting the Alarm Verification Delay
29
Applying Alarm Verification Delay to a Detector
29
Restoring the Panels Default Settings
30
Viewing Panel Information
31
Menu Structure
31
Viewing Device Status
32
Locating a Device
32
Using the Event Log
33
The Fire Alarm Condition
34
Viewing a Fire Alarm Event
34
Viewing Faults During a Fire Alarm Condition
34
Viewing Zone Disablements During a Fire Alarm Condition
34
Viewing Device Disablements During a Fire Alarm Condition
34
Viewing Zones in Test Mode During a Fire Alarm Condition
34
Disablement
35
Zone Disablement
35
To Programme Zone (or Sounders) as Disabled
35
Device Disablement
36
Viewing Disablements
36
Viewing Disabled Zones
36
Viewing Disabled Devices
36
Test Mode
37
Why Use Test Mode
37
To Programme Zone in Test Mode
37
To Program Sounder Circuits in Test Mode
37
General Fault Finding
38
Common Fault
38
Zone Contents Fault Finding
38
Zone Faults
38
Supply Faults
39
Earth Faults
39
Double Address
39
System Fault
40
Standby Battery Calculation
41
Device Values for Battery Calculation
41
Example Battery Calculation
42
Pcb Termination Connections
43
Specifications
44
Enclosure Specifications
44
Electrical Specifications
44
Zeta INFINITY ID2 User Manual (27 pages)
INTELLIGENT 2 WIRE FIRE DETECTION SYSTEM WITH ‘ID’ TECHNOLOGY
Brand:
Zeta
| Category:
Fire Alarms
| Size: 1.44 MB
Table of Contents
Table of Contents
2
What to Do if the Fire Alarm Panel Shows an Alarm (Red Led)
3
What to Do if the Fire Alarm Panel Shows a Fault (Yellow Led)
3
1 Fire Alarm Control Panel Safety Issues
4
2 The Purpose of a Fire Alarm System
4
3 User Responsibilities & Maintainence of the Fire Alarm System, Including the Facp & Its Integral Pse
5
4 Panel Indications & Controls
6
Panel Indications
6
Panel Controls
6
In the Event of an Alarm
6
Access Levels
6
Checking the Panels Indication Leds
7
What the Leds Mean
7
5 The Fire Condition
8
How the Simplicity Indicates an Alarm
8
To Turn off the Alarm Sounders
8
A Second Alarm Signal from a New Detection Zone
8
Turning on the Alarm Sounders from the Facp (I.e. to Evacuate the Building)
8
Resetting the Panel
8
6 The Fault Condition
9
Different Types of Fault
9
What to Do if a Fault Condition Occurs
10
Other Led Indications
11
7 Disablements
12
Reasons for Disabling Certain Parts of a Fire Alarm System
12
To Disable a Zone And/Or External Sounders
12
To Enable a Zone And/Or External Sounders
12
8 System Description
13
9 Fire Alarm Log Book
15
Maintenance Work
16
All Events Other than Maintenance Work or False Alarms (Continued)
21
10 Commissioning the System, Including Power Supply Equipment P.s.e
22
Design, Installation & Commissioning Certificates
22
Design Certificate
23
Installation Certificate
25
Commissioning Certificate
26
Acceptance Certificate
27
Advertisement
Zeta INFINITY ID2 User Manual, Maintenance Manual & Log Book (27 pages)
INTELLIGENT 2 WIRE FIRE DETECTION SYSTEM WITH 'ID' TECHNOLOGY
Brand:
Zeta
| Category:
Fire Alarms
| Size: 1.5 MB
Table of Contents
Table of Contents
2
What to Do if the Fire Alarm Panel Shows an Alarm (Red Led)
3
What to Do if the Fire Alarm Panel Shows a Fault (Yellow Led)
3
Fire Alarm Control Panel Safety Issues
4
The Purpose of a Fire Alarm System
4
User Responsibilities & Maintainence of the Fire Alarm System, Including the Facp & Its Integral Pse
5
Panel Indications & Controls
6
Panel Indications
6
Panel Controls
6
In the Event of an Alarm
6
Access Levels
6
Checking the Panels Indication Leds
7
What the Leds Mean
7
The Fire Condition
8
How the Simplicity Indicates an Alarm
8
To Turn off the Alarm Sounders
8
A Second Alarm Signal from a New Detection Zone
8
Turning on the Alarm Sounders from the Facp (I.e. to Evacuate the Building)
8
Resetting the Panel
8
The Fault Condition
9
Different Types of Fault
9
What to Do if a Fault Condition Occurs
10
Other Led Indications
11
Disablements
12
Reasons for Disabling Certain Parts of a Fire Alarm System
12
To Disable a Zone And/Or External Sounders
12
To Enable a Zone And/Or External Sounders
12
System Description
13
Fire Alarm Log Book
15
All Events Other than Maintenance Work or False Alarms (Continued)
21
Commissioning the System, Including Power Supply Equipment P.s.e
22
Design, Installation & Commissioning Certificates
22
Advertisement
Related Products
Zeta ID2/2
Zeta ID2/8
Zeta ID2/4
Zeta ID2/8/M
Zeta ID2/2/M
Zeta INFINITY ID2/4/M
ZETA INFINITY 8
Zeta 126
Zeta CP-CV
Zeta CP-KY
Zeta Categories
Fire Alarms
Control Panel
Smoke Alarm
Security System
Control Unit
More Zeta Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL