Sign In
Upload
Manuals
Brands
SICK Manuals
Accessories
LMS5 Series
SICK LMS5 Series Measurement Sensors Manuals
Manuals and User Guides for SICK LMS5 Series Measurement Sensors. We have
3
SICK LMS5 Series Measurement Sensors manuals available for free PDF download: Operating Instructions Manual
SICK LMS5 Series Operating Instructions Manual (112 pages)
2D LiDAR sensors
Brand:
SICK
| Category:
Accessories
| Size: 4 MB
Table of Contents
Table of Contents
3
About this Document
6
Information on the Operating Instructions
6
Explanation of Symbols
6
Further Information
7
Safety Information
8
Intended Use
8
Improper Use
8
Cybersecurity
8
Limitation of Liability
8
Modifications and Conversions
9
Requirements for Skilled Persons and Operating Personnel
9
Operational Safety and Specific Hazards
9
Product Description
11
Scope of Delivery
11
Device Variants
11
Device Views
12
Functional Scope of the Different Device Variants
13
Heavy Duty Variants with Ventilation Element
14
Extended Range Variants
16
Type Code
17
Type Label
17
Status Indicators
18
Principle of Operation
19
Measurement Principle
19
Range Finding
20
Direction Measurement
20
Impact of Object Surfaces on the Measurement
21
Distance between the Device and the Object/Surface to be Monitored
22
Sensing Range
23
Beam Diameter and Measuring Point Distance
24
Minimum Object Size
27
Contamination Measurement
28
Calculation of the Field Size for Mobile Applications
29
Switching Field Length
29
Switching Field Width
31
Fields of Application
31
Object Measurement
31
Basic Parameters
31
Interlaced Mode
33
Multi-Echo Analysis
35
Filter
35
Output of Measured Values
38
RSSI Values
40
Field Application
42
Detection Fields
43
Evaluation Cases
44
Linking of Evaluation Cases at the Output
47
Inputs and Outputs
47
Data Interfaces
50
Communicating Data Via Telegrams
51
Transport and Storage
52
Transport
52
Unpacking
52
Transport Inspection
52
Storage
52
Mounting
53
Mounting Instructions
53
Mounting the Device
53
Mounting Multiple Devices
54
Electrical Installation
55
Wiring Instructions
55
Overview of the Installation Steps
55
Prerequisites for Safe Operation of the Device
56
Connections
59
Connections of the LMS500
59
Connections of LMS511, LMS581 and LMS511 Heavy Duty
62
Connections of the LMS531 Security Outdoor
64
Connections of the LMS511 with Harting Male Connector
67
Preparing Electrical Installation
68
SELV Supply Voltage
68
Wire Cross-Sections for LMS500 Indoor
68
Wire Cross-Sections for Lms5X1 Outdoor
69
Cable Reserve on System Plug
70
General Conditions for Data Interfaces
70
Performing the Electrical Installation
70
Connection to the Auxiliary Interface (USB) and the Ethernet Interface of the Device
70
LMS500: Wiring System Plug
71
LMS511 / LMS531 / LMS581: Connecting M12 Round Connectors
72
Wiring the Inputs and Outputs
72
Commissioning
76
Overview of the Commissioning Steps
76
SOPAS et Configuration Software
76
Establishing Communication with the Device
77
Initial Commissioning
78
Parameterizing the LMS531 Variants for Security Applications
80
Default - Standard Mode and Expertmode
81
Detection Fields/Monitored Areas
82
Operating Mode
82
Day/Night Switching (LMS531 Pro)
83
Digital Outputs and Relay Outputs
83
Easyteach
84
Special Functions
87
Connecting and Performing a Test Measurement
90
Maintenance
92
Cleaning
92
Maintenance Plan
92
Device Replacement
93
Exchange of the LMS500 Lite/Pro or LMS511 Heavy Duty When Reusing the Previous System Plug (Parameter Cloning)
93
Complete Replacement of the LMS511 Lite/Pro, LMS531
94
Lite/Pro Security and LMS581 PRO (Without Reuse of the Previous System Plug)
94
Parameter Cloning
95
Troubleshooting
96
Repairs
96
Returns
96
General Faults, Warnings, and Errors
96
LED Fault Indicators
96
Indicators in the 7-Segment Display
97
Detailed Fault Analysis
97
Disposal
98
Technical Data
99
Features
99
Performance
102
Interfaces
103
Mechanics/Electronics
105
Ambient Data
106
Dimensional Drawings
108
Accessories
110
Annex
111
Declarations of Conformity and Certificates
111
Advertisement
SICK LMS5 Series Operating Instructions Manual (122 pages)
LASER MEASUREMENT SENSORS
Brand:
SICK
| Category:
Accessories
| Size: 4 MB
Table of Contents
Table of Contents
3
1 About this Document
5
Information Regarding the Operating Instructions
5
Scope
5
Depth of Information
6
Explanation of Symbols
7
Further Information
8
Customer Service
8
2 For Your Safety
9
Correct Use
9
Incorrect Use
9
IP Technology
9
Limitation of Liability
9
Modifications and Conversions
10
Requirements for Skilled Persons and Operating Personnel
10
General Safety Notes and Protective Measures
11
Hazard Warnings and Operational Safety
12
Quick Stop and Restart
14
Environmental Protection
14
Repair
15
3 Product Description
17
Delivery
17
Device Variants
18
Type Code
20
Special Features of the Lms5Xx
21
Differences between the Lms5Xx Lite, PRO and Heavy Duty Versions
22
Controls and Status Indicators
23
Operating Principle of the Lms5Xx
24
Applications
31
Measurement of Objects
32
Field Application
39
Inputs and Outputs
44
Data Interfaces
47
Data Communication Using Telegrams
48
Planning
49
4 Transport and Storage
51
Transport
51
Transport Inspection
51
Storage
51
5 Mounting
53
Overview of the Mounting Steps
53
Preparations for Mounting
53
Dismanteling the System
62
6 Electrical Installation
63
Overview of the Installation Steps
63
Conditions for Safe Operation of the Lms5Xx in an Installation
63
Connections of the Lms5Xx
67
Preparing the Electrical Installation
74
Perform Electrical Installation on the Lms5Xx
76
7 Commissioning and Configuration
85
Overview of the Commissioning Steps
85
SOPAS ET Configuration Software
85
Establish Communication with the Lms5Xx
86
Initial Commissioning
88
Connection and Test Measurement
90
8 Maintenance
91
Maintenance During Operation
91
Exchanging an Lms5Xx
91
Decommissioning
95
9 Troubleshooting
97
In the Event of Faults or Errors
97
Error Displays of the Indicator Lights
97
Indications of the 7-Segment Display
98
Detailed Error Analysis
98
SICK Support
99
10 Technical Specifications
101
Data Sheet Lms5Xx Laser Measurement Sensor
101
Operating Range Diagrams
106
Dimensional Drawings
107
11 Annex
115
Ordering Information
115
EU Declaration of Conformity
115
Glossary
115
Abbreviations
116
List of Figures
117
List of Tables
119
SICK LMS5 Series Operating Instructions Manual (94 pages)
2D LiDAR sensors
Brand:
SICK
| Category:
Accessories
| Size: 4 MB
Table of Contents
Table of Contents
3
1 About this Document
6
Information on the Operating Instructions
6
Scope
6
Explanation of Symbols
7
Further Information
7
2 Safety Information
8
Intended Use
8
Improper Use
8
Internet Protocol (IP) Technology
8
Limitation of Liability
8
Modifications and Conversions
9
Requirements for Skilled Persons and Operating Personnel
9
Operational Safety and Particular Hazards
10
3 Product Description
11
Scope of Delivery
11
Device Variants
11
Heavy Duty Variants with Aeration and Ventilation Membrane
13
Type Code
14
Type Label
15
Status Indicators
16
Principle of Operation
17
Measurement Principle
17
Range Finding
17
Direction Measurement
18
Impact of Object Surfaces on the Measurement
18
Distance between the Device and the Object/Surface to be Monitored
20
Sensing Range
21
Beam Diameter and Measuring Point Distance
21
Minimum Object Size
23
Contamination Measurement
24
Calculation of the Field Size for Mobile Applications
25
Fields of Application
27
Object Measurement
27
Field Application
37
Inputs and Outputs
42
Data Interfaces
45
Communicating Data Via Telegrams
46
4 Transport and Storage
48
Transport
48
Unpacking
48
Transport Inspection
48
Storage
48
5 Mounting
50
Mounting Instructions
50
Mounting the Device
50
Mounting Multiple Devices
51
6 Electrical Installation
52
Wiring Instructions
52
Overview of the Installation Steps
52
Prerequisites for Safe Operation of the Device
53
Connections
56
Connections of the LMS500
56
Connections of LMS511, LMS581 and LMS511 Heavy Duty
59
Connections of the LMS531 Security Outdoor
61
Connections of the LMS511 with Harting Male Connector
64
Preparing Electrical Installation
65
SELV Supply Voltage
65
LMS500 Indoor Cable Cross-Section
65
Lms5X1 Outdoor Cable Cross-Section
66
Cable Reserve on System Plug
67
General Conditions for Data Interfaces
67
Performing the Electrical Installation
67
Connection to the Auxiliary Interface (USB) and the Ethernet Interface of the Device
67
LMS500: Wiring System Plug
68
LMS511 / LMS531 / LMS581: Connecting M12 Round Connector
68
Wiring the Inputs and Outputs
69
7 Commissioning
72
Overview of the Commissioning Steps
72
SOPAS ET Configuration Software
72
Establishing Communication with the Device
73
Initial Commissioning
74
Connecting and Performing a Test Measurement
75
8 Maintenance
77
Cleaning
77
Maintenance Plan
77
Device Replacement
78
Exchange of the LMS500 Lite/Pro or LMS511 Heavy Duty When Reusing the Previous System Plug (Parameter Clon- Ing)
78
Complete Replacement of the LMS511 Lite/Pro, LMS531 Lite/Pro Security and LMS581 PRO (Without Reuse of the Previous System Plug)
79
Parameter Cloning
80
9 Troubleshooting
81
Repairs
81
Returns
81
General Faults, Warnings, and Errors
81
LED Fault Indicators
81
Indicators in the 7-Segment Display
82
Detailed Fault Analysis
82
Disposal
83
10 Technical Data
84
Features
84
Performance
86
Interfaces
86
Mechanics/Electronics
88
Ambient Data
89
Dimensional Drawings
90
11 Accessories
92
12 Annex
93
EU Declaration of Conformity/Certificates
93
Cybersecurity
93
Advertisement
Advertisement
Related Products
SICK Bulkscan LMS511
SICK LMS500-20000 PRO Indoor
SICK LMS500-21000 Lite Indoor
SICK LMS511-12100 Heavy Duty Outdoor
SICK LMS511-20100 PRO Outdoor
SICK LMS511-21100 Lite Outdoor
SICK LMS511-22100 Heavy Duty Outdoor
SICK LMS531-10100 PRO Security Outdoor
SICK LMS531-11100 Lite Security Outdoor
SICK LMS511-10100 PRO Outdoor
SICK Categories
Accessories
Security Sensors
Measuring Instruments
Scanner
Barcode Reader
More SICK Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL