Sign In
Upload
Manuals
Brands
SICK Manuals
Accessories
Bulkscan LMS511
User Manuals: SICK Bulkscan LMS511 Flow Sensor
Manuals and User Guides for SICK Bulkscan LMS511 Flow Sensor. We have
2
SICK Bulkscan LMS511 Flow Sensor manuals available for free PDF download: Operating Instructions Manual
SICK Bulkscan LMS511 Operating Instructions Manual (112 pages)
2D LiDAR sensors
Brand:
SICK
| Category:
Accessories
| Size: 4 MB
Table of Contents
Table of Contents
3
About this Document
6
Information on the Operating Instructions
6
Explanation of Symbols
6
Further Information
7
Safety Information
8
Intended Use
8
Improper Use
8
Cybersecurity
8
Limitation of Liability
8
Modifications and Conversions
9
Requirements for Skilled Persons and Operating Personnel
9
Operational Safety and Specific Hazards
9
Product Description
11
Scope of Delivery
11
Device Variants
11
Device Views
12
Functional Scope of the Different Device Variants
13
Heavy Duty Variants with Ventilation Element
14
Extended Range Variants
16
Type Code
17
Type Label
17
Status Indicators
18
Principle of Operation
19
Measurement Principle
19
Range Finding
20
Direction Measurement
20
Impact of Object Surfaces on the Measurement
21
Distance between the Device and the Object/Surface to be Monitored
22
Sensing Range
23
Beam Diameter and Measuring Point Distance
24
Minimum Object Size
27
Contamination Measurement
28
Calculation of the Field Size for Mobile Applications
29
Switching Field Length
29
Switching Field Width
31
Fields of Application
31
Object Measurement
31
Basic Parameters
31
Interlaced Mode
33
Multi-Echo Analysis
35
Filter
35
Output of Measured Values
38
RSSI Values
40
Field Application
42
Detection Fields
43
Evaluation Cases
44
Linking of Evaluation Cases at the Output
47
Inputs and Outputs
47
Data Interfaces
50
Communicating Data Via Telegrams
51
Transport and Storage
52
Transport
52
Unpacking
52
Transport Inspection
52
Storage
52
Mounting
53
Mounting Instructions
53
Mounting the Device
53
Mounting Multiple Devices
54
Electrical Installation
55
Wiring Instructions
55
Overview of the Installation Steps
55
Prerequisites for Safe Operation of the Device
56
Connections
59
Connections of the LMS500
59
Connections of LMS511, LMS581 and LMS511 Heavy Duty
62
Connections of the LMS531 Security Outdoor
64
Connections of the LMS511 with Harting Male Connector
67
Preparing Electrical Installation
68
SELV Supply Voltage
68
Wire Cross-Sections for LMS500 Indoor
68
Wire Cross-Sections for Lms5X1 Outdoor
69
Cable Reserve on System Plug
70
General Conditions for Data Interfaces
70
Performing the Electrical Installation
70
Connection to the Auxiliary Interface (USB) and the Ethernet Interface of the Device
70
LMS500: Wiring System Plug
71
LMS511 / LMS531 / LMS581: Connecting M12 Round Connectors
72
Wiring the Inputs and Outputs
72
Commissioning
76
Overview of the Commissioning Steps
76
SOPAS et Configuration Software
76
Establishing Communication with the Device
77
Initial Commissioning
78
Parameterizing the LMS531 Variants for Security Applications
80
Default - Standard Mode and Expertmode
81
Detection Fields/Monitored Areas
82
Operating Mode
82
Day/Night Switching (LMS531 Pro)
83
Digital Outputs and Relay Outputs
83
Easyteach
84
Special Functions
87
Connecting and Performing a Test Measurement
90
Maintenance
92
Cleaning
92
Maintenance Plan
92
Device Replacement
93
Exchange of the LMS500 Lite/Pro or LMS511 Heavy Duty When Reusing the Previous System Plug (Parameter Cloning)
93
Complete Replacement of the LMS511 Lite/Pro, LMS531
94
Lite/Pro Security and LMS581 PRO (Without Reuse of the Previous System Plug)
94
Parameter Cloning
95
Troubleshooting
96
Repairs
96
Returns
96
General Faults, Warnings, and Errors
96
LED Fault Indicators
96
Indicators in the 7-Segment Display
97
Detailed Fault Analysis
97
Disposal
98
Technical Data
99
Features
99
Performance
102
Interfaces
103
Mechanics/Electronics
105
Ambient Data
106
Dimensional Drawings
108
Accessories
110
Annex
111
Declarations of Conformity and Certificates
111
Advertisement
SICK Bulkscan LMS511 Operating Instructions Manual (92 pages)
Laser volume flowmeter for the throughput measurement of bulk goods
Brand:
SICK
| Category:
Accessories
| Size: 5 MB
Table of Contents
Table of Contents
3
1 About this Document
6
Purpose of this Document
6
Target Group
6
Information Depth
6
Scope
6
Abbreviations Used
7
Symbols Used
7
2 On Safety
8
Authorized Personnel
8
Correct Use
8
General Safety Notes and Protective Measures
8
Electrical Installation Work
9
Laser Radiation
9
Damaging Potential Equalization Currents Due to Different Ground Potentials
11
Quick Stop and Quick Restart
11
Environmental Protection
12
Power Consumption
12
Disposal after Final Decommissioning
12
IP Technology
12
3 Product Description
13
Special Features of the Bulkscan
13
Operating Principle of the Bulkscan
13
Measurement Principle
13
Application Examples
14
Status Indicators
15
4 Configurable Functions
16
Setting the Belt Speed
16
Measurement of the Volume
17
Measurement of the Mass
17
Measurement of Volume Flow Rate
18
Measurement of the Mass Flow Rate
18
Measurement of the Bulk Density
19
Measurement of the Bulk Height
19
Monitoring the Center of Gravity
20
Monitoring the Bulk Edge
22
Monitoring the Conveyor Belt Edge
23
Averaging Filter
24
Digital Inputs
24
Digital Outputs
25
Analog Module BAM100
26
Data Interfaces
27
Ethernet Interface
27
Serial Host Interface
27
Serial Auxiliary Interface/Usb
28
5 Mounting
29
Placing Mounting Materials Ready
29
Selecting the Mounting Location
29
Mounting the Sensor
30
Direct Mounting
31
Mounting with Mounting Kit 1
31
Mounting with Mounting Kit 2
32
Mounting with Mounting Kit 3
33
Mounting with Mounting Bracket on Existing Mounting Kit Lms2Xx
34
Mounting with Mounting Bracket and Mast Bracket
35
Removing the Sensor
35
6 Electrical Installation
36
Requirements for the Electrical Installation
36
Avoiding Potential Differences
36
Suitable Power Supply
38
Cable Lengths and Wire Cross-Sections
38
Carrying out the Electrical Installation on the Bulkscan
38
Supply Voltage Connection
39
Connection of the Digital Inputs/Outputs
39
Ethernet Interface Connection
40
Serial Interface Connection
40
Mini-USB Connection
41
Wiring the Inputs and Outputs to the External Components
42
Wiring Non-Floating Digital Inputs
42
Wiring Floating Digital Inputs
42
Wiring Encoder Inputs
43
Input Circuits IN1 and IN2
43
Connecting the Outputs to a PLC
43
Analog Inputs/Outpus with Analog Module BAM100
44
Module Design
44
Installation of Bus Terminals on Mounting Rails
45
Power Supply BC9050
46
Analog Input Terminal KL3454
47
Analog Output KL4424
48
7 Configuration
49
Configuring the Bulkscan with SOPAS
49
Installing the SOPAS Configuration Software
49
Establishing Communication with the Bulkscan
50
Configuration of the Bulkscan Using Telegrams
51
8 Commissioning
53
Teaching-In the Reference Contour
53
Compensation of the Conveyor Belt Level
55
Optimization for Conveyor Belts with Slits or Gaps
56
Performing a Test Measurement
57
Setting Tolerances
57
Tolerance against Vibration
58
Tolerance against Reflection
58
Optimization for Outdoor Applications
58
Ignore Measurement Points below the Reference Contour
59
Monitoring of the Contamination Degree
60
Scan Frequency
61
Taking a Reference Measurement (Compensation Function)
61
9 Maintenance and Care
64
Cleaning the Front Screen
64
Replacing a Bulkscan
64
10 Fault Diagnosis
65
Response to Errors
65
SICK Suport
65
Error and Status Indicators on the 7 Segment Display
65
Status Indication BAM100
66
11 Technical Data
68
Bulkscan LMS511 Data Sheet
68
Analog Module BAM100 Data Sheet
70
Dimensional Drawings
71
Dimensional Drawing Bulkscan LMS511
71
Dimensional Drawings Mounting Kits
72
Dimensional Drawing Mounting Bracket for Existing Lms2Xx Mounting Kit
75
Dimensional Drawing Mounting Bracket with Mast Bracket
76
Dimensional Drawing Analog Module BAM100
76
12 Ordering Information
77
Scope of Delivery
77
Accessories
77
13 Appendix
80
Telegram Reference
80
Notation and Examples
80
Logging in to the Sensor/Logging out of the Sensor
82
Saving The Configuration In The Non-Volatile Memory
83
Device Information
83
Operating Mode/Teach-In
83
Measured Values
84
Measurement
84
System
85
Edge Monitoring
86
Digital Inputs
86
Digital Outputs
87
Reference Measurement (Compensation Function)
88
Service Data
90
Error Codes (Sfa)
90
8014829/Znc5/2017-06-06| S I C K
90
Advertisement
Related Products
SICK LMS511-12100 Heavy Duty Outdoor
SICK LMS511-20100 PRO Outdoor
SICK LMS511-21100 Lite Outdoor
SICK LMS511-22100 Heavy Duty Outdoor
SICK LMS511-10100 PRO Outdoor
SICK LMS511-11100 Lite Outdoor
SICK LMS5 1 Series
SICK LMS511 Heavy Duty
SICK LMS531-11100 Lite Security Outdoor
SICK LMS581-10100 PRO Outdoor
SICK Categories
Accessories
Security Sensors
Measuring Instruments
Scanner
Barcode Reader
More SICK Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL