Sign In
Upload
Manuals
Brands
OMRON Manuals
Temperature Controller
E5ZE-8
OMRON E5ZE-8 Manuals
Manuals and User Guides for OMRON E5ZE-8. We have
1
OMRON E5ZE-8 manual available for free PDF download: Communications Manual
OMRON E5ZE-8 Communications Manual (168 pages)
Multipoint Temperature Controller
Brand:
OMRON
| Category:
Temperature Controller
| Size: 1.41 MB
Table of Contents
Table of Contents
3
About this Manual
7
Part 1 Devicenet Communications
8
Overview of Communications Functions
9
Devicenet
10
Remote I/O
10
Devicenet Explicit Message Communications
10
Communications Setup
11
Cable Connections
12
Communications Parameters
12
Section 3 Remote I\/O Communications
14
Remote I/O Communications
14
Transmission Contents and Word Allocations
15
Reading Process Values
15
Reading Status
16
Alarm Status
16
Auto-Tuning Status
16
Operating Status
17
Temperature Control Start/Stop
18
Startup Operation
18
Writing Set Points
19
Manual Operation
19
Remote I/O Delay Time
20
Section 4 Devicenet Explicit Message Communications
21
Devicenet Explicit Message Communications
21
Transmitting Devicenet Explicit Messages
22
Command Format
22
E5ZE Fixed Command Configuration
23
Commands
23
Remote I/O and Devicenet Explicit Messages
23
Instruction Execution Precautions
24
CMND(194/490): CVM1, CV-Series, and CS1-Series Pcs
24
IOWR(223): C200HX/C200HE/C200HG Pcs
24
Devicenet Explicit Messages Set Values and Measurement Values
25
Reading/Writing Using Variable Type 90
31
Operation Variables
31
Relationship between Operating Status and Operating Commands
32
Set Values in Memory Banks
32
Measurement Values for Individual Control Points
34
Set Values for All Control Points
35
Communications Errors
37
End Codes
37
End Codes
38
Checking Fins Command 2801 End Code
38
Checking Devicenet Error Codes
38
Checking 0101 (Read) and 0102 (Write) Commands End Codes
39
Indicators
41
Section 6 Communications Program Examples
43
Communications Program Examples
43
CVM1 and CV-Series Pcs
44
Ladder Program Example
46
C200HX/C200HE/C200HG Pcs
51
C200HX/C200HG/C200HE Pcs
51
CS1 Pcs
58
Using Programs
58
Appendix Amulti-Vendor Applications
65
Section 1 Serial Communications Control
70
Serial Communications Control
70
Communications Control Procedure
71
Block Format
72
FCS Calculations
72
Checks
73
Error Processing
73
Section 2 Commands and Responses
74
Commands and Responses
74
Commands
75
Heating and Cooling Control
80
Writing Sets of Data
81
Reading Sets of Data
83
End Codes
84
End Codes
85
Error Codes
88
Section 3 Basic Temperature Control Commands
89
Basic Temperature Control Commands
89
Set Point Write: WS
90
Set Point Read: RS
91
Process Value Read: RX
92
Output Value Read: RO
94
Proportional Band Write: WB
95
Proportional Band Read: RB
96
Integral Time Write: WN
97
Integral Time Read: RN
98
Derivative Time Write: WV
99
Derivative Time Read: RV
100
Control Period Write: WT
101
Control Period Read: RT
102
Output Operation (Normal/Reverse) Write: WU
103
Output Operation (Direct/Reverse) Read: RU
104
Alarm Mode Write: W
105
Alarm Mode Read: R
106
Alarm Temperature Write: W
108
Alarm Temperature Read: R
109
Memory Bank Designation Write: WM
110
Memory Bank Designation Read: RM
111
Hysteresis Write: WH
112
Hysteresis Read: RH
113
Status Read: RX
114
Error Read: RU
117
Section 4 Commands According to Application
120
Commands According to Application
120
Auto-Tuning Start: as
121
Auto-Tuning Stop: AP
122
Setting Unit Write: Wt
122
Setting Unit Read: Rt
124
Input Shift Write: WI
125
Input Shift Read: RI
126
Manual Reset Value Write: WK
127
Manual Reset Value Read: RK
128
Ramp Value Write: WR
128
Ramp Value Read: RR
129
Present Set Point Read: Rs
130
Manual Output Value Write: wo
132
Output Variable Limit Value Write: WL
133
Output Variable Limit Value Read: RL
134
Output Variable Change Rate Limit Value Write: WG
135
Output Variable Change Rate Limit Value Read: RG
137
Memory Write
137
Initialize Setting Data: MC
138
Communication Test: TS
139
Heater Burnout and SSR Failure Detection Commands
141
HB Alarm and HS Alarm Point Write: WU
142
HB Alarm and HS Alarm Point Read: RU
143
Heater Burnout and SSR Failure Detection Current Value Write: WW
144
Heater Burnout and SSR Failure Detection Current Value Read: RW
145
Heater Current Value and SSR Leakage Current Value Read: RZ
146
Section 6 Heating and Cooling Control Commands
148
Heating and Cooling Control Commands
148
Dead Band and Overlap Band Write: WD
149
Dead Band and Overlap Band Read: RD
150
Cooling Coefficient Write: WC
150
Cooling Coefficient Read: RC
151
Fuzzy Control Commands
153
Fuzzy Strength Write: Wj
154
Fuzzy Strength Read: Rj
155
Fuzzy Scale 1 Write: Wk
155
Fuzzy Scale 1 Read: Rk
156
Fuzzy Scale 2 Write: Wl
157
Fuzzy Scale 2 Read: Rl
158
Control Operation Start and Stop Commands
160
Operation Start: os
161
Operation Stop: OP
161
Manual Operation Start: OM
162
Revision History
168
Advertisement
Advertisement
Related Products
Omron E5ZE-8AAAMTC-E
Omron E5ZE-8AAAMP-E
Omron E5ZE-8VAAMTC-E
Omron E5ZE-8VAAMP-E
Omron E5ZE-8AAAMTCB-E
Omron E5ZE-8AAAMPB-E
Omron E5ZE-8VAAMTCB-E
Omron E5ZE-8VAAMPB-E
Omron E5ZE-8AQHD1TCB-V2
Omron E5ZE-8AQHD1PB-V2
OMRON Categories
Blood Pressure Monitor
Controller
Accessories
Switch
Inverter
More OMRON Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL