Sign In
Upload
Manuals
Brands
Keysight Technologies Manuals
Test Equipment
DSO1022A
Keysight Technologies DSO1022A Manuals
Manuals and User Guides for Keysight Technologies DSO1022A. We have
2
Keysight Technologies DSO1022A manuals available for free PDF download: User Manual, Service Manual
Keysight Technologies DSO1022A User Manual (154 pages)
Brand:
Keysight Technologies
| Category:
Test Equipment
| Size: 1 MB
Table of Contents
Keysight 1000A Series Oscilloscopes-At a Glance
3
Table 1. Keysight 1000A Series Oscilloscope Models
3
In this Book
4
Table of Contents
5
Figures
13
Tables
15
Getting Started
17
Step 1. Inspect the Package Contents
18
Step 2. Turn on the Oscilloscope
19
Figure 1. Power Switch
19
Step 3. Load the Default Oscilloscope Setup
20
Figure 2. [Default Setup] Key
20
Step 4. Input a Waveform
21
Step 5. Use Auto-Scale
22
Figure 3. [Auto-Scale] Key
22
Table 2. Auto-Scale Default Settings
23
Step 6. Compensate Probes
24
Low Frequency Compensation
24
Figure 4. Low Frequency Probe Compensation
24
Step 7. Become Familiar with the Front Panel Controls
25
Figure 5 Front Panel
25
Front Panel Overlays for Different Languages
26
Table 3. Front Panel Controls
26
Using the Oscilloscope Softkey Menus
27
Figure 6 Softkey Menus
27
Step 8. Become Familiar with the Oscilloscope Display
29
Figure 7. Oscilloscope Display
29
Step 9. Use the Run Control Keys
30
Figure 8. Run Control Keys
30
Step 10. Access the Built-In Help
31
Figure 9. [Help] Key
31
Securing the Oscilloscope
32
Figure 10 Securing the Instrument
32
Displaying Data
33
Using the Horizontal Controls
34
Figure 11. Horizontal Controls
34
To Adjust the Horizontal Scale
35
Figure 12. Status Bar, Trigger Position, and Horizontal Scale Control
35
To Adjust the Horizontal Position
36
To Display the Zoomed Time Base
37
Figure 13 Zoomed Time Base Window
37
To Change the Horizontal Time Base (Y-T, X-Y, or Roll)
38
Figure 14 X-Y Display Format Showing Out-Of-Phase Waveforms
39
To View the Sample Rate
40
Using the Vertical Controls
41
To Turn Waveforms on or off (Channel, Math, or Reference)
41
To Adjust the Vertical Scale
41
Figure 15. Vertical Controls
41
To Adjust the Vertical Position
42
To Specify Channel Coupling
43
Figure 16 DC Coupling Control
43
To Specify a Bandwidth Limit
44
Figure 17 AC Coupling Control
44
Figure 18 BW Limit Control off
45
Figure 19 BW Limit Control on
45
To Specify the Probe Attenuation
46
To Use a Digital Filter
46
To Change the Volts/DIV Control Sensitivity
47
To Invert a Waveform
47
Figure 20 Waveform before Inversion
48
To Specify the Channel Units
49
Figure 21 Waveform after Inversion
49
Using Math Function Waveforms
50
To Add, Subtract, or Multiply Waveforms
50
Figure 22 Math Scale Setting Value
50
To Display the Frequency Domain Using FFT
51
Table 4. FFT Window Characteristics
52
Figure 23 FFT Waveform
53
Using Reference Waveforms
54
To Save a Reference Waveform
54
To Export or Import Reference Waveforms
54
To Return the Reference Waveform to Its Default Scale
55
Changing the Display Settings
56
To Display Waveforms as Vectors or Dots
56
To Clear the Display
56
Figure 24. [Display] Key
56
To Set Waveform Persistence
57
To Adjust Waveform Intensity
57
To Display Graded Waveform Intensity
58
To Change the Grid
58
To Change the Menu Display Time
58
To Adjust the Grid Brightness
59
To Invert Screen Colors
59
To Select Screen Persistence
60
Capturing Data
61
Overview of Sampling
62
Sampling Theory
62
Aliasing
62
Oscilloscope Bandwidth and Sample Rate
63
Figure 25 Alaising
63
Figure 26 Theoretical Brick-Wall Frequency Response
64
Oscilloscope Rise Time
65
Figure 27. Sample Rate and Oscilloscope Bandwidth
65
Oscilloscope Bandwidth Required
66
Real-Time Sampling
67
Figure 28 Real-Time Sampling Mode
67
Memory Depth and Sample Rate
68
Choosing the Acquisition Mode
69
To Select the Normal Acquisition Mode
69
To Select the Average Acquisition Mode
69
Figure 29. Acquire Key
69
Figure 30 Noisy Waveform Without Averaging
70
Figure 31 Noisy Waveform with Averaging
70
To Select the Peak Detect Acquisition Mode
71
Figure 32 Peak Detect Waveform
72
To Turn OFF/ON Sine(X)/X Interpolation
73
Recording/Playing-Back Waveforms
74
To Record Waveforms
74
To Play-Back Waveforms
75
To Store Recorded Waveforms
76
Adjusting the Trigger Level
78
To Adjust the Trigger Level
78
To Force a Trigger
78
Figure 33 Trigger Controls
78
Choosing the Trigger Mode
80
To Set up Edge Triggers
80
To Set up Pulse Width Triggers
81
To Set up Video Triggers
82
Figure 34 Line Synchronization
83
To Set up Pattern Triggers
84
Figure 35 Field Synchronization
84
To Set up Alternate Triggers
85
Figure 36 Alternate Triggers
86
Setting Other Trigger Parameters
87
To Set the Trigger Sweep
87
To Set the Trigger Coupling
87
To Set the Trigger High-Frequency Reject Coupling
88
To Change the Trigger Sensitivity
89
To Specify a Trigger Holdoff
90
Figure 37 Trigger Holdoff
90
Using the External Trigger Input
91
Making Measurements
93
Displaying Automatic Measurements
94
To Display an Automatic Measurement
94
Figure 38. [Measure] Key
94
To Clear Automatic Measurements from the Display
95
To Display or Hide All Automatic Measurements
95
To Select Channels for Delay/Phase Measurements
95
Voltage Measurements
96
Vmax (Maximum Voltage)
96
Figure 39 Voltage Measurement Points
96
Vmin (Minimum Voltage)
97
Vpp (Peak-To-Peak Voltage)
97
Vtop (Top Voltage)
97
Vbase (Base Voltage)
97
Vamp (Amplitude Voltage = Vtop - Vbase)
97
Vavg (Average Voltage)
97
Vrms (Root-Mean-Square Voltage)
97
Overshoot
98
Preshoot
98
Time Measurements
99
Period
99
Figure 40 Period and Frequency Measurements
99
Frequency
100
Rise Time
100
Fall Time
100
Figure 41. Rise Time and Fall Time Measurements
100
Positive Pulse Width
101
Negative Pulse Width
101
Positive Duty Cycle
101
Negative Duty Cycle
101
Figure 42. Positive Pulse Width and Negative Pulse Width Measurements
101
Delay between Rising Edges
102
Delay between Falling Edges
102
Figure 43. Delay Measurements
102
Phase between Rising Edges
103
Phase between Falling Edges
103
Figure 44. Phase Measurements
103
Counter (Frequency)
104
Making Cursor Measurements
105
To Use Manually Adjustable Cursors
105
Figure 45. [Cursors] Key
105
To Use Tracking Cross-Hair Cursors
106
To Display Cursors for Automatic Measurements
107
Saving, Recalling, and Printing Data
109
Figure 46 USB Host Port on Front Panel
109
Saving and Recalling Data
110
To Save and Recall Waveforms
110
Figure 47. [Save/Recall] Key
110
To Save and Recall Oscilloscope Setups
111
To Save Screens to BMP or PNG Format Files
112
To Save Data to CSV Format Files
113
Using the Disk Manager
114
Figure 48 Disk Manager
114
To Switch between Files, Path, and Directory Panes
115
To Navigate the Directory Hierarchy
115
To Create New Folders
115
To Edit Folder/File Names
116
Figure 49 Editing Folder/File Names in Disk Manager
116
To Delete Folders
117
To Rename Folders
117
To Delete Files
117
To Recall Files
117
To Rename Files
118
To Display Disk Information
118
Printing Screens
119
Figure 50 USB Ports on Back Panel
119
To Choose a Pictbridge Printer
120
Figure 51. [Print] Key Location
120
To Print with Inverted Screen Colors
121
To Choose Color or Grayscale Printing
121
To Copy a Screen to the Printer
121
Figure 52 [Utility] Key
123
Oscilloscope Utility Settings
124
Displaying System Information
124
Turning Sound on or off
124
Setting and Displaying the Date and Time
124
Setting the Language (Menu and Help)
125
Performing Mask Tests
126
To Enable/Disable Mask Tests
126
To Select the Source Channel for Mask Tests
126
To Run/Stop a Mask Test
127
To Turn On/Off the Mask Test Message Display
127
To Set the Mask Test Output Condition
127
Figure 53. Mask Test Display
127
To Stop a Mask Test on the Output Condition
128
To Set up Masks
128
Figure 54 Mask Test Mask Setting
129
Setting Preferences
131
To Set up the Screen Saver
131
To Select the Vertical Scale Reference Level
131
To Select the USB Device Port Function
131
Running Self-Calibration
132
Figure 55 Calibration Screen
133
Specifications and Characteristics
136
Environmental Conditions
136
Overvoltage Category
136
Pollution Degree
136
Pollution Degree Definitions
136
Measurement Category
137
Measurement Category Definitions
137
Maximum Input Voltages
137
Specifications
138
Table 5 Specifications
138
Characteristics
139
Table 6. Acquisition System Characteristics
139
Table 7. Vertical System Characteristics
139
Table 8. Horizontal System Characteristics
141
Table 9. Trigger System Characteristics
142
Table 10 Display System Characteristics
142
Table 11 Measurement Features
143
Table 12 FFT Measurement Features
143
Table 13 Storage
144
Table 14 I/O
144
Table 15 General Characteristics
145
Table 16 Power Requirements
145
Table 17 Environmental Characteristics
146
Table 18 Other
146
Warnings
147
Safety Symbols
148
Advertisement
Keysight Technologies DSO1022A Service Manual (46 pages)
Brand:
Keysight Technologies
| Category:
Test Equipment
| Size: 1 MB
Table of Contents
Keysight 1000A Series Oscilloscopes-At a Glance
3
Table 1. Keysight 1000A Series Oscilloscope Models
3
In this Book
4
Table of Contents
5
Figures
7
Tables
9
Service
11
Cleaning the Oscilloscope
12
Testing Performance
13
Before Testing Performance
14
Table 2. Equipment Required to Perform All Tests
14
To Test DC Gain Accuracy
16
Table 3. DC Gain Accuracy Specification
16
Table 4. Equipment Required for DC Gain Accuracy Test
16
Figure 1 Averages Menu Item
17
Figure 2 Connecting Equipment for DC Gain Accuracy Test
18
Figure 3 Vavg Menu Item
19
To Test Analog Bandwidth, Maximum Frequency
21
Table 5 Analog Bandwidth Specification
21
Table 6. Equipment Required for Analog Bandwidth Test
22
Figure 4. Connecting Equipment for Maximum Frequency Check Test
23
Figure 5 Channel 1 Vertical Scale Setting
24
Figure 6 Channel 1 Horizontal Scale Setting
24
Figure 7 Averages Menu Item
25
Figure 8 Signal Generator Waveform
26
Table 7 Oscilloscope Models and Signal Generator Frequency
27
To Test Time Scale Accuracy
29
Table 8 Time Scale Accuracy Specification
29
Figure 9. Connecting Equipment for Time Scale Accuracy Test
30
Table 9. Equipment Required for Time Scale Accuracy Test
30
To Test Trigger Sensitivity
32
Table 10 Trigger Sensitivity Specification
32
Table 11 Equipment Required for Trigger Sensitivity Test
32
Figure 10 Connecting Equipment for Trigger Sensitivity Test
33
Performance Test Record
35
Table 12 Performance Test Information
35
Table 13 DC Gain Test
35
Table 14 Analog Bandwidth - Maximum Frequency Check
37
Table 15 Time Scale Accuracy
38
Table 16 Trigger Sensitivity
38
Returning the Oscilloscope to Keysight for Service
39
Contacting Keysight
40
A Safety Notices
41
Warnings
41
Safety Symbols
42
Index
43
Advertisement
Related Products
Keysight Technologies DSO1024A
Keysight Technologies DSO1014A
Keysight Technologies DSO1004A
Keysight Technologies DSO1012A
Keysight Technologies DSO1002A
Keysight Technologies DSO-X 2012A
Keysight Technologies DSOX1102A
Keysight Technologies InfiniiVision DSOX1204A
Keysight Technologies InfiniiVision DSOX1204G
Keysight Technologies 1000A Series
Keysight Technologies Categories
Measuring Instruments
Test Equipment
Control Unit
Portable Generator
Power Supply
More Keysight Technologies Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL