Sign In
Upload
Manuals
Brands
Keysight Technologies Manuals
Test Equipment
DSOX1102A
Keysight Technologies DSOX1102A Manuals
Manuals and User Guides for Keysight Technologies DSOX1102A. We have
2
Keysight Technologies DSOX1102A manuals available for free PDF download: User Manual, Service Manual
Keysight Technologies DSOX1102A User Manual (104 pages)
Brand:
Keysight Technologies
| Category:
Test Equipment
| Size: 2 MB
Table of Contents
Infiniivision 1000 X-Series Oscilloscopes-At a Glance
4
In this Guide
6
Table of Contents
9
1 Getting Started
13
Inspect the Package Contents
14
Power-On the Oscilloscope
15
Connect Probes to the Oscilloscope
16
Maximum Input Voltage at Analog Inputs
16
Do Not Float the Oscilloscope Chassis
16
Input a Waveform
17
Recall the Default Oscilloscope Setup
18
Use Autoscale
19
Compensate Passive Probes
20
Learn the Front Panel Controls and Connectors
22
Front Panel Overlays for Different Languages
27
Learn the Rear Panel Connectors
28
Learn the Oscilloscope Display
29
Access the Built-In Quick Help
31
2 Quick Reference
33
Running, Stopping, and Making Single Acquisitions (Run Control)
34
Horizontal Controls
35
Horizontal Knobs and Keys
35
Horizontal Softkey Controls
35
Zoom
36
Vertical Controls
38
Vertical Knobs and Keys
38
Vertical Softkey Controls
38
Setting Analog Channel Probe Options
40
Analog Bus Display
41
FFT Spectral Analysis
42
FFT Measurement Hints
42
FFT DC Value
44
FFT Aliasing
44
FFT Spectral Leakage
45
Math Waveforms
46
Units for Math Waveforms
47
Reference Waveforms
48
Display Settings
49
To Load a List of Labels from a Text File You Create
50
Triggers
52
Trigger Knobs and Keys
52
Trigger Types
52
Trigger Mode, Coupling, Reject, Holdoff
53
External Trigger Input
55
Acquisition Control
56
Selecting the Acquisition Mode
56
Overview of Sampling
57
Cursors
63
Cursor Knobs and Keys
63
Cursor Softkey Controls
63
Measurements
65
Mask Testing
67
Creating/Editing Mask Files
67
Digital Voltmeter
74
Frequency Response Analysis
75
Waveform Generator
77
Serial Bus Decode/Trigger
78
CAN Decode/Trigger
79
I2C Decode/Trigger
80
LIN Decode/Trigger
80
SPI Decode/Trigger
81
UART/RS232 Decode/Trigger
82
Save/Recall (Setups, Screens, Data)
84
Length Control
85
Print (Screens)
87
Utility Settings
88
USB Storage Devices
89
Configuring the [Quick Action] Key
90
Specifications and Characteristics
91
Environmental Conditions
92
Declaration of Conformity
92
Probes and Accessories
93
Software and Firmware Updates
94
Acknowledgements
95
Product Markings and Regulatory Information
97
Advertisement
Keysight Technologies DSOX1102A Service Manual (60 pages)
50/70/100 MHz
Brand:
Keysight Technologies
| Category:
Test Equipment
| Size: 1 MB
Table of Contents
In this Service Guide
3
Table of Contents
5
Figures
9
Tables
11
1 Characteristics and Specifications
13
Power Requirements
13
Measurement Category
14
Measurement Category Definitions
14
Transient Withstand Capability
14
Environmental Conditions
15
Specifications
16
Contact Us
16
2 Testing Performance
17
Overview
18
List of Test Equipment
19
Table 1 List of Test Equipment
19
Conventions
20
Table 2 Conventions
20
Table 3. DC Vertical Gain Accuracy Test Limits
21
Table 4. Equipment Required to Verify DC Vertical Gain Accuracy
21
To Verify DC Vertical Gain Accuracy
21
Table 5. Settings Used to Verify DC Vertical Gain Accuracy
22
Figure 1. Setting up Equipment for DC Vertical Gain Accuracy Test
24
Figure 2 Using a Blocking Capacitor to Reduce Noise
25
Table 6. Bandwidth (-3 Db) Test Limits
26
Table 7. Equipment Required to Verify Bandwidth (-3 Db)
26
To Verify Band Width (-3 Db)
26
To Verify Bandwidth (-3 Db)
26
Figure 3. Setting up Equipment for Bandwidth (-3 Db) Verification Test
27
Table 8. Equipment Required to Verify Time Base Accuracy
30
To Verify Time Base Accuracy
30
To Verify Trigger Sensitivity
32
Table 9. Equipment Required to Verify Trigger Sensitivity
32
Table 10 Internal Trigger Sensitivity Specifications
33
Test Internal Trigger Sensitivity
33
Figure 4. Setting up Equipment for Internal Trigger Sensitivity Test
34
Test External Trigger Sensitivity
36
Table 11 External Trigger Sensitivity Specifications
36
Figure 5 Setting up Equipment for External Trigger Sensitivity Test
37
Keysight 1000 X-Series Oscilloscopes Performance Test Record
39
3 Calibrating and Adjusting
41
User Calibration
42
To Perform User Cal
42
User Cal Status
42
4 Troubleshooting
43
Solving General Problems with the Oscilloscope
44
If There Is no Display
44
If There Is no Trace Display
44
If the Trace Display Is Unusual or Unexpected
44
If You Cannot See a Channel
45
Verifying Basic Operation
46
To Power-On the Oscilloscope
46
To Perform Hardware Self Test
46
To Perform Front Panel Self Test
47
To Verify Default Setup
47
Figure 6 Default Setup Screen
48
To Perform an Auto Scale on the Probe Comp Signal
49
To Compensate Passive Probes
50
Figure 7 Example Pulses
50
5 Replacing Assemblies
51
6 Replaceable Parts
53
7 Safety Notices
55
Warnings
56
To Clean the Instrument
57
Safety Symbols
58
Advertisement
Related Products
Keysight Technologies DSO-X 2002A
Keysight Technologies DSO-X 2012A
Keysight Technologies DSO-X 2022A
Keysight Technologies DSO-X 2004A
Keysight Technologies DSO-X 2024A
Keysight Technologies DSOX1102G with DSX1B7T12
Keysight Technologies InfiniiVision DSOX1204A
Keysight Technologies InfiniiVision DSOX1204G
Keysight Technologies DSO1024A
Keysight Technologies DSO1012A
Keysight Technologies Categories
Measuring Instruments
Test Equipment
Control Unit
Portable Generator
Power Supply
More Keysight Technologies Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL