Sign In
Upload
Manuals
Brands
Itron Manuals
Remote Control
OpenWay Riva
Itron OpenWay Riva Manuals
Manuals and User Guides for Itron OpenWay Riva. We have
10
Itron OpenWay Riva manuals available for free PDF download: Installation Manual, User Manual
ITRON OpenWay Riva Installation Manual (42 pages)
Pit Water Module
Brand:
ITRON
| Category:
Control Unit
| Size: 1 MB
Table of Contents
Table of Contents
3
Chapter 1 Important Safety and Compliance Information
5
FCC Part 15 Rules
5
Lithium Battery Safety
6
Modifications and Repairs
6
Disconnecting Power
6
Electromagnetic Compatibility
7
Electrostatic Discharge
7
Drop Height Limitation
7
Chapter 2 About the Openway Riva Water Module
8
Openway Riva Water Pit Module Description
8
Related Documents
9
Itron Security Manager (ISM)
9
Enabling Openway Riva Water Pit Module Security
10
Battery Life
10
Openway Riva Water Pit Module Transmission Modes
10
Openway Riva Water Pit Module Operating Modes
10
Error/Warning Flags
11
Chapter 3 Initializing, Connecting, and Programming the Openway Riva Water Pit Module
13
Openway Riva Water Pit Module Start-Up
13
Programming the Pit Module
13
Extending the Water Pit Module Cable
14
Connecting the Pit Module to an Encoder-Type Meter Register
14
Connecting the Pit Module to a Pulser-Type Meter Register
15
Verifying Pit Module Operation
16
Chapter 4 Installing the Openway Riva Water Pit Module
17
Pit Module Mounting Accessories
18
Pit Modules with Integral Connectors
18
Through-Lid Installation
19
Through-Lid Mount Required Tools and Hardware
19
Installing the Module in the Pit Lid
20
Rod Mount Installation
21
Rod Mounting Required Tools and Hardware
21
Installing the Pit Module on a Rod
22
Wall Mount Installation
24
Installing the Module to the Pit Wall
24
Optional Riva Leak Sensor Installation
26
Riva Leak Sensor Installation Equipment
27
Pipe Preparation
27
Installing the Leak Sensor
28
Connecting the Leak Sensor to the Module
29
Attaching a Security Seal to the Completed Connection
29
Optional Remote Water Disconnect Valve Installation
30
Installing the Remote Water Disconnect Valve
30
Optional Through-The-Lid Remote Antenna Installation
34
Openway Riva Through-The-Lid Remote Antenna
35
Installing the Through-The-Lid Remote Antenna
36
Connecting the Through-The-Lid Remote Antenna Module
37
Chapter 5 Using the Itron Cable Armor
38
Installing the Itron Cable Armor
38
Chapter 6 Connecting the Inline Connector
40
Chapter 7 Troubleshooting
42
Advertisement
Itron OpenWay Riva Installation Manual (43 pages)
Water Pit Module
Brand:
Itron
| Category:
Control Unit
| Size: 0 MB
Table of Contents
Table of Contents
3
Chapter 1 Important Safety and Compliance Information
5
USA, FCC Part 15 Spectrum Compliance
5
Canada, ISED Spectrum Compliance
6
RF Exposure (FCC/ISED)
6
Lithium Battery Safety
7
Modifications and Repairs
7
Electromagnetic Compatibility
7
Electrostatic Discharge
7
Do Not Drop
7
Chapter 2 About the Openway Riva Water Module
8
Openway Riva Water Pit Module Description
9
Related Documents
9
Itron Security Manager (ISM)
10
Battery Life
10
Openway Riva Pit Module Transmission Modes
10
Openway Riva Pit Module Operating Modes
11
Openway Riva Water Module Firmware Functionality
12
Events and Alarms
12
Chapter 3 Initializing, Connecting, and Programming the Pit Module
14
Openway Riva Water Pit Module Start-Up
14
Programming the Pit Module
14
Extending the Water Pit Module Cable
15
Pit Module Encoder-Type Meter Register Connections
15
Pit Module Pulser-Type Register Connections
17
Verifying Pit Module Operation
17
Chapter 4 Installing the Openway Riva Water Pit Module
18
Pit Module Mounting Accessories
19
Pit Modules with Integral Connectors
19
Through-Lid Installation
20
Through-Lid Mount Required Tools and Hardware
20
Installing the Module in the Pit Lid
21
Rod Mount Installation
22
Rod Mounting Required Tools and Hardware
23
Installing the Pit Module on a Rod
23
Wall Mount Installation
26
Installing the Module to the Pit Wall
26
Leak Sensor (OLS) Installation with the Pit Water Module
28
Optional Remote Water Disconnect Valve Installation
29
Installing the Remote Water Disconnect Valve
30
Optional Through-The-Lid Remote Antenna Installation
32
Openway Riva Through-The-Lid Remote Antenna
33
Installing the Through-The-Lid Remote Antenna
33
Connecting the Remote Antenna
34
Appendix A Using the Itron Cable Armor
36
Installing the Itron Cable Armor
36
Appendix B Connecting the Inline Connector
38
Appendix C Completing Gel-Cap Connections Using the Itron Splice Kit
40
Appendix D Troubleshooting
43
ITRON OpenWay Riva Installation Manual (40 pages)
Water Remote Module
Brand:
ITRON
| Category:
Control Unit
| Size: 0 MB
Table of Contents
Table of Contents
3
Chapter 1 Important Safety and Compliance Information
5
USA, FCC Part 15 Spectrum Compliance
5
Canada, ISED Spectrum Compliance
6
RF Exposure (FCC/ISED)
6
Lithium Battery Safety
7
Modifications and Repairs
7
Disconnecting Power
7
Electromagnetic Compatibility
7
Electrostatic Discharge
7
Do Not Drop
8
Chapter 2 About the Openway Riva Remote Module
9
Openway Riva Remote Module Description
10
Related Documents
10
Itron Security Manager (ISM)
11
Battery Life
11
Remote Module Transmission Modes
11
Openway Riva Remote Module Operating Modes
12
Openway Riva Water Module Firmware Functionality
13
Events and Alarms
14
Chapter 3 Initializing and Connecting the Openway Riva Remote Module
15
Initializing the Remote Module
15
Programming
15
Remote Module Encoder-Type Register Connections
16
Remote Module Pulser-Type Register Connections
18
Connecting the Remote Module Using an Extension Cable
18
Verifying Remote Module Operation
18
Chapter 4 Installing the Openway Riva Remote Module
20
Remote Module Mounting Accessories
20
Installing the Module Cable Strain Relief
21
Securing the Remote Module Cable Strain Relief
21
Installing the Remote Riva Module Backplate
22
Attaching the Backplate
23
Pipe Mount Installation
24
Mounting the Pipe Bracket on a Vertical Pipe
24
Adapter Plate Mounting Positions
25
Mounting the Remote Module on the Adapter Plate
26
Openway Riva Leak Sensor (OLS) Installation with a Remote Water Module
26
Connecting the SET Valve to the Remote Riva Water Module
27
Completing the SET Valve Wire Connections
27
Remote Mount Installation
28
Installing the Openway Riva Remote Module on a Flat Surface
28
Direct-Mounting the Module to the Meter Register
29
Direct-Mounting on the ABB Scancoder, Invision, or Digital Direct-Mount
30
Direct-Mounting to a Badger Direct-Mount Register
32
Appendix A Completing Gel-Cap Connections Using the Itron Splice Kit
35
Appendix B Using the Itron Cable Armor
38
Installing the Itron Cable Armor
38
Appendix C Troubleshooting
40
Advertisement
ITRON OpenWay Riva Installation Manual (37 pages)
Remote Water Module
Brand:
ITRON
| Category:
Control Unit
| Size: 0 MB
Table of Contents
Table of Contents
3
Chapter 1 Important Safety and Compliance Information
5
FCC Part 15 Rules
5
Lithium Battery Safety
6
Modifications and Repairs
6
Disconnecting Power
6
Electromagnetic Compatibility
7
Electrostatic Discharge
7
Drop Height Limitation
7
Chapter 2 About the Openway Riva Remote Module
8
Openway Riva Remote Module Description
9
Related Documents
9
Itron Security Manager (ISM)
9
Enabling Openway Riva Remote Module Security
10
Battery Life
10
Openway Riva Remote Module Transmission Modes
10
Operating Modes
10
Error and Warning Flags
11
Chapter 3 Initializing and Connecting the Openway Riva Remote Module
13
Initializing, Programming, and Connecting the Openway Riva Remote Module
13
Programming
13
Connecting the Remote Water Module to an Encoder-Type Register
14
Connecting the Remote Module to a Pulser-Type Register
15
Connecting the Remote Module Using an Extension Cable
16
Verifying Openway Riva Remote Module Operation
16
Chapter 4 Mounting the Openway Riva Remote Module
17
Remote Module Mounting Accessories
17
Installing the Module Cable Strain Relief
18
Securing the Remote Module Cable Strain Relief
18
Attaching the Backplate
19
Attaching the Backplate
20
Pipe Mount Installation
21
Mounting the Pipe Bracket on a Vertical Pipe
21
Adapter Plate Mounting Positions
22
Mounting the Remote Module on the Adapter Plate
23
Optional Riva Leak Sensor Installation
24
Connecting the Leak Sensor to the Openway Riva Water Remote Module
25
Riva Leak Sensor Installation Equipment
25
Pipe Preparation
25
Installing the Leak Sensor
25
Connecting the SET Valve to the Remote Riva Water Module
27
Completing the SET Valve Wire Connections
27
Remote Mount Installation
27
Installing the Openway Riva Remote Module on a Flat Surface
27
Direct-Mounting the Module to the Meter Register
29
Direct-Mounting on the ABB Scancoder, Invision, or Digital Direct-Mount
30
Direct-Mounting to a Badger Direct-Mount Register
32
Chapter 5 Using the Itron Cable Armor
35
Installing the Itron Cable Armor
35
Chapter 6 Troubleshooting
37
ITRON OpenWay Riva Installation Manual (34 pages)
Gas Disconnect
Brand:
ITRON
| Category:
Control Unit
| Size: 0 MB
Table of Contents
Table of Contents
3
1 Important Safety and Compliance Information
5
USA, FCC Part 15 Spectrum Compliance
5
Canada, ISED Spectrum Compliance
6
RF Exposure (FCC/ISED)
6
Electromagnetic Compatibility
6
Intrinsic Safety
6
Telemetering Equipment Classification
7
Lithium Battery
7
Transportation Classification
7
Modifications, Repairs, Installation, and Removal
7
Aluminum Enclosure
7
Electrostatic Discharge
8
Electrostatic Ignition Hazard
8
Device Cleaning
8
Do Not Drop
8
Product Notification
8
2 OWRGD Installation Guide Overview
10
Audience
10
3 About the Openway Riva Gas Disconnect
11
OWRGD Models
12
OWRGD System Security
13
Transmission Mode
13
Operational States
13
OWRGD Functional Specifications
13
OWRGD Operational Specifications
14
Related Documents
14
4 Installing the OWRGD
16
OWRGD Installation, Commissioning, and Decommissioning
16
OWRGD Accessories
16
Meter Set Installation
17
OWRGD Valve Positions
20
Installing the OWRGD in the Pipe
20
Installing the Flood Sensor
22
5 Connecting the Flood Sensor to the OWRGD
25
Connecting the Flood Sensor Inline Connector
25
6 OWRGD Operations
28
OWRGD Secure Commands
28
Obtaining Security Material
28
OWRGD Valve Commands
29
Performing Get Commands
29
Check Endpoint/Valve Status
29
Emergency Override
30
Commission
30
Commission Instructions
31
Connect
31
Connect Instructions
31
Disconnect
32
Disconnect Instructions
32
Decommission
33
Decommissioning Instructions
33
Programming the OWRGD
33
Performing Network Operations
33
ITRON OpenWay Riva Installation Manual (30 pages)
Gas Remote Disconnect valve
Brand:
ITRON
| Category:
Control Unit
| Size: 0 MB
Table of Contents
Table of Contents
3
Chapter 1 Important Safety and Compliance Information
5
USA, FCC Part 15 Spectrum Compliance
5
Canada, ISED Spectrum Compliance
6
RF Exposure (FCC/ISED)
6
Electromagnetic Compatibility
6
Telemetering Equipment Classification
7
Intrinsic Safety
7
Lithium Battery
7
Transportation Classification
7
Modifications, Repairs, Installation, and Removal
7
Aluminum Enclosure
8
Electrostatic Discharge
8
Electrostatic Ignition Hazard
8
Device Cleaning
8
Do Not Drop
8
Product Notification
9
Chapter 2 Openway Riva Gas Remote Disconnect Installation Guide Overview
10
Audience
10
Chapter 3 About the Openway Riva Gas Remote Disconnect
11
Openway Riva Gas Remote Disconnect Models
12
Openway Riva Gas Remote Disconnect System Security
12
Transmission Mode
13
Operational States
13
Openway Riva Gas Remote Disconnect Functional Specifications
13
Openway Riva Gas Remote Disconnect Operational Specifications
14
Related Documents
14
Chapter 4 Installing the Openway Riva Gas Remote Disconnect
15
Openway Riva Gas Remote Disconnect Installation, Commissioning, and Decommissioning
15
Openway Riva Gas Remote Disconnect Accessories
15
Meter Set Installation
16
Openway Riva Gas Remote Disconnect Valve Positions
18
Installing the Openway Riva Gas Remote Disconnect in the Pipe
19
Installing the Flood Sensor
20
Mounting the Flood Sensor on the Pipe
20
Mounting the Flood Sensor on a Flat Surface
21
Chapter 5 Connecting the Flood Sensor to the Openway Riva Gas Remote Disconnect
22
Connecting the Flood Sensor Inline Connector
22
Chapter 6 Openway Riva Gas Remote Disconnect Operations
24
Openway Riva Gas Remote Disconnect Secure Commands
24
Obtaining Security Material
24
Performing a Get Commands
25
Programming the Openway Riva Remote Disconnect
25
Performing Network Operations
25
Openway Riva Gas Remote Disconnect Valve Commands
26
Valve Status
26
Connect
27
Disconnect
28
Commission
29
Decommission
30
Itron OpenWay Riva Installation Manual (27 pages)
Gas Remote Disconnect
Brand:
Itron
| Category:
Remote Control
| Size: 0 MB
Table of Contents
Installation Guide
1
Table of Contents
3
Chapter 1 Important Safety and Compliance Information
5
USA, FCC Part 15 Compliance
5
Canada, ISED Compliance
6
RF Exposure (FCC/ISED)
6
Electromagnetic Compatibility
6
Telemetering Equipment Classification
7
Intrinsic Safety
7
Lithium Battery
7
Transportation Classification
7
Modifications, Repairs, Installation, and Removal
7
Aluminum Enclosure
8
Electrostatic Discharge
8
Electrostatic Ignition Hazard
8
Device Cleaning
8
Do Not Drop
8
Product Notification
9
Chapter 2 Openway Riva Gas Remote Disconnect Installation Guide Overview
10
Audience
10
Chapter 3 About the Openway Riva Gas Remote Disconnect
11
Openway Riva Gas Remote Disconnect Models
11
Openway Riva Gas Remote Disconnect System Security
12
Enabling Openway Riva Gas Remote Disconnect Security
12
Transmission Mode
12
Operational States
12
Openway Riva Gas Remote Disconnect Functional Specifications
13
Openway Riva Gas Remote Disconnect Operational Specifications
13
Related Documents
14
Chapter 4 Installing the Openway Riva Gas Remote Disconnect
15
Initial Calibration and Alignment
15
Openway Riva Gas Remote Disconnect Installation, Commissioning, and Decommissioning
16
Openway Riva Gas Remote Disconnect Accessories
16
Meter Set Installation
17
Openway Riva Gas Remote Disconnect Valve Positions
18
Installing the Openway Riva Gas Remote Disconnect in the Pipe
18
Installing the Flood Sensor
19
Mounting the Flood Sensor on the Pipe
20
Mounting the Flood Sensor on a Flat Surface
20
Chapter 5 Connecting the Flood Sensor to the Openway Riva Gas Remote Disconnect
22
Connecting the Flood Sensor Inline Connector to the Openway Riva Gas Remote Disconnect
22
Chapter 6 Openway Riva Gas Remote Disconnect Programming
24
Sending Openway Riva Gas Remote Disconnect Secure Commands
24
Get Commands
24
Performing a Get Commands
24
Commissioning the Openway Riva Gas Remote Disconnect
25
Performing an Openway Riva Gas Remote Disconnect Valve Commissioning
25
Connecting the Openway Riva Gas Remote Disconnect
25
Connection Instructions
25
Disconnecting the Openway Riva Gas Remote Disconnect
26
Closing the Openway Riva Gas Remote Disconnect Valve to Disconnect Service
26
Decommissioning the Openway Riva Gas Remote Disconnect
27
Decommissioning Instructions
27
ITRON OpenWay Riva Installation Manual (25 pages)
Routing Node, ERT Gateway
Brand:
ITRON
| Category:
Gateway
| Size: 0 MB
Table of Contents
Table of Contents
3
Chapter 1 Important Safety and Compliance Information
4
USA, FCC Part 15 Compliance
4
Canada, ISED Compliance
5
RF Exposure (FCC/ISED)
5
Electromagnetic Compatibility
5
Chapter 2 Getting Started: Openway
6
ERT Gateway Related Documents
6
Installation Location Information
7
ERT Gateway Components
7
ERT Gateway Housing
8
ERT Gateway Antennas
9
Chapter 3 Planning an ERT Gateway Installation
10
Installation Profiles
10
Siting the ERT Gateway
10
Propagation Study for the ERT Gateway Installation Site
11
AC Power Requirements
11
AC Mains Power
11
Mounting Hardware Requirements
12
Chapter 4 Installing the ERT Gateway
13
Installation Overview
13
Mounting the ERT Gateway Antennas
13
Attaching the Standard 915Mhz ERT Antenna
13
Attaching the SNIC Antenna
15
Mounting the ERT Gateway
15
Mounting Hardware
16
Mounting the ERT Gateway on a Pipe
17
Mounting the ERT Gateway on a Pole
18
Mounting the ERT Gateway on a Davit Arm
19
Connecting the Ground Wire
20
Connecting the ERT Gateway Power
20
Connecting the Power Cable
21
ERT Gateway Wiring Diagram
21
Chapter 5 Openway Riva Routing Node Communications Software
23
Appendix A ERT Gateway Specifications
24
Dimensions and Weight
24
Antenna Specifications
24
Environmental Specifications
25
ERT Gateway Power Operating Range
25
ITRON OpenWay Riva Installation Manual (21 pages)
Leak Sensor
Brand:
ITRON
| Category:
Accessories
| Size: 7 MB
Table of Contents
Table of Contents
3
Chapter 1 Important Safety and Compliance Information
4
Modifications and Repairs
4
Electrostatic Discharge
4
Do Not Drop
4
Chapter 2 Openway ® Riva Leak Sensor Installation Guide Overview
5
Audience
5
Related Documents
5
Chapter 3 About the Openway Riva Leak Sensor (OLS)
6
Openway Riva Leak Sensor Spacing Guidelines
6
1:6 Deployment Ratio
6
1:4 Deployment Ratio
7
1:3 Deployment Ratio
7
1:2 Deployment Ratio
7
Chapter 4 Openway Riva Leak Sensor Compatibility with the 100W+ ERT Module
8
Programming the 100W+ Module for OLS Compatibility
8
Chapter 5 Openway Riva Leak Sensor Installation
11
Openway Riva Leak Sensor Installation Equipment
11
Leak Sensor (OLS) Installation with the Pit Water Module
12
Installing the OLS
13
Connecting the OLS
14
Attaching a Security Seal
15
Openway Riva Leak Sensor (OLS) Installation with a Remote Water Module
16
Installing the OLS with the Remote Itron Module
16
Appendix A Using Gel-Cap Connectors
20
ITRON OpenWay Riva User Manual (13 pages)
ACT module
Brand:
ITRON
| Category:
Control Unit
| Size: 2 MB
Advertisement
Related Products
ITRON OpenWay Intelis
ITRON OpenWay Riva IRM-STAR
ITRON OpenWay Riva IRM-MESH
ITRON OpenWay OWR-1000-001
ITRON ECW-1700-002
Itron Categories
Measuring Instruments
Control Unit
Controller
Data Loggers
Industrial Equipment
More Itron Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL