Sign In
Upload
Manuals
Brands
ICP DAS USA Manuals
Control Unit
ET-2255
ICP DAS USA ET-2255 Manuals
Manuals and User Guides for ICP DAS USA ET-2255. We have
6
ICP DAS USA ET-2255 manuals available for free PDF download: User Manual, Quick Start Manual
ICP DAS USA ET-2255 User Manual (125 pages)
Ethernet I/O Modules
Brand:
ICP DAS USA
| Category:
I/O Systems
| Size: 8.74 MB
Table of Contents
Table of Contents
2
Introduction
5
Packing List
5
Features
6
Hardware Information
10
Appearance
10
Specification
12
System Specification
12
I/O Specification
13
Pin Assignments
19
Wiring Connections
24
Input Wiring
24
Output Wiring
25
Wiring to the Connector
27
Dimensions
28
Getting Started
30
Configuring the Boot Mode
30
Connecting the Power and the Host Pc
31
Configuring the Network Settings
32
Modbus Tcp Testing
34
Web Configuration
36
Logging in to the Web Server
36
Home
38
Network
39
IP Address Configuration
39
Dynamic Configuration
41
Manual Configuration
41
General Settings
42
Restore Factory Defaults
43
Firmware Update
45
I/O Settings
46
DO Control
46
DI/DO Configuration
47
Sync
50
DIO Synchronization
50
Pwm
52
PWM Configuration
52
Pair Connection
53
I/O Pair-Connection Settings
53
Filter
56
Filter Settings
56
Monitor
58
Change Password
59
Logout
60
Mqtt
61
Connectivity Settings
62
Publication Settings
63
Restore Factory Defaults
65
Mqtt-Do
66
MQTT - Digital Outputs
66
Readbacks of the Digital Outputs
67
Mqtt-DI
69
MQTT - Digital Inputs
69
Mqtt- Realization
71
Set up Mosquitto
71
Introduction to Mqttlens
77
2200 Periodic Publish Realization
80
I/O Pair Connection Applications
82
One Module Polling the Remote DI/Do (1- to -1, Pull / Push Mode )
82
Pull Mode
84
Push Mode
85
Two Modules Pushing the Local DI to each Other (1-To-1, Push Mode)
86
Several Modules Pulling the Remote DI (M-To-1) (Pull Mode)
89
Several Modules Pushing the Local DI (M-To-1) (Push Mode)
92
Modbus Information
95
What Is Modbus Tcp/Ip
95
Modbus Message Structure
96
0X01) Read the Status of the Coils (Read DO Readback Vaslues)
99
0X02) Read the Status of the Input (Read DI Values)
101
0X03) Read the Holding Registers (Read AO Readback Values )
103
0X04) Read the Input Registers (Read AI Values)
105
0X05) Force a Single Coil (Write DO Value)
107
0X06) Set a Single Register (Write AO Value)
109
0X0F) Force Multiple Coils (Write DO Values)
111
0X10) Set Multiple Registers (Write AO Values)
113
Modbus Register Table
115
Common Functions
115
2Specific Functions
117
Appendix A: Troubleshooting
123
How Do Irestore the Web Password for the Module to the Factory Default Password
123
Appendix B: Revision History
125
Advertisement
ICP DAS USA ET-2255 User Manual (99 pages)
Ethernet I/O Modules
Brand:
ICP DAS USA
| Category:
I/O Systems
| Size: 4.04 MB
Table of Contents
Table of Contents
2
Introduction
5
Features
5
Hardware Information
9
Appearance
9
Specification
11
System Specification
11
I/O Specification
12
2242
12
2251
12
2254/2254P
13
2255
14
2260
15
2261
16
2268
17
Pin Assignments
18
2242
18
2251
18
2254/2254P
19
2255
19
2260
20
2261
20
2268
21
Wiring Connections
22
Input Wiring
22
Output Wiring
23
Wiring to the Connector
25
Dimensions
26
Getting Started
27
Configuring the Boot Mode
27
Connecting the Power and the Host Pc
28
Configuring the Network Settings
29
Modbus Tcp Testing
31
Web Configuration
33
Logging in to the Web Server
33
Home
35
Network
36
IP Address Configuration
36
Dynamic Configuration
38
Manual Configuration
38
General Settings
39
Restore Factory Defaults
40
Firmware Update
42
I/O Settings
43
DO Control
43
DI/DO Configuration
44
Sync
47
DIO Synchronization
47
Pwm
49
PWM Configuration
49
Pair Connection
51
I/O Pair-Connection Settings
51
Filter
54
Filter Settings
54
Monitor
56
Change Password
57
Logout
58
I/O Pair Connection Applications
59
One Module Polling the Remote DI/DO (1-To-1, Polling Mode)
59
Polling Mode
61
Push Mode
62
Two Modules Pushing the Local DI to each Other (1-To-1, Push Mode)
63
Several Modules Polling the Remote DI (M-To-1) (Polling Mode)
66
Several Modules Pushing the Local DI (M-To-1) (Push Mode)
69
Modbus Information
72
What Is Modbus Tcp/Ip
72
Modbus Message Structure
73
0X01) Read the Status of the Coils (Readback Dos)
76
0X02) Read the Status of the Input (Read Dis)
78
0X03) Read the Holding Registers (Readback Aos)
80
0X04) Read the Input Registers (Read Ais)
82
0X05) Force a Single Coil (Write DO)
84
0X06) Preset a Single Register (Write AO)
86
0X0F) Force Multiple Coils (Write Dos)
88
0X10) Preset Multiple Registers (Write Aos)
90
Modbus Register Table
92
Common Functions
92
Specific Functions
94
ICP DAS USA ET-2255 User Manual (99 pages)
Ethernet I/O Modules
Brand:
ICP DAS USA
| Category:
I/O Systems
| Size: 5.87 MB
Table of Contents
Table of Contents
2
Introduction
5
Features
5
Hardware Information
9
Appearance
9
Specification
11
System Specification
11
I/O Specification
12
2242
12
2251
12
2254/2254P
13
2255
14
2260
15
2261
16
2268
17
Pin Assignments
18
2242
18
2251
18
2254/2254P
19
2255
19
2260
20
2261
20
2268
21
Wiring Connections
22
Input Wiring
22
Output Wiring
23
Wiring to the Connector
25
Dimensions
26
Getting Started
27
Configuring the Boot Mode
27
Connecting the Power and the Host Pc
28
Configuring the Network Settings
29
Modbus Tcp Testing
31
Web Configuration
33
Logging in to the Web Server
33
Home
35
Network
36
IP Address Configuration
36
Dynamic Configuration
38
Manual Configuration
38
General Settings
39
Restore Factory Defaults
40
Firmware Update
42
I/O Settings
43
DO Control
43
DI/DO Configuration
44
Sync
47
DIO Synchronization
47
Pwm
49
PWM Configuration
49
Pair Connection
51
I/O Pair-Connection Settings
51
Filter
54
Filter Settings
54
Monitor
56
Change Password
57
Logout
58
I/O Pair Connection Applications
59
One Module Polling the Remote DI/DO (1-To-1, Polling Mode)
59
Polling Mode
61
Push Mode
62
Two Modules Pushing the Local DI to each Other (1-To-1, Push Mode)
63
Several Modules Polling the Remote DI (M-To-1) (Polling Mode)
66
Several Modules Pushing the Local DI (M-To-1) (Push Mode)
69
Modbus Information
72
What Is Modbus Tcp/Ip
72
Modbus Message Structure
73
0X01) Read the Status of the Coils (Readback Dos)
76
0X02) Read the Status of the Input (Read Dis)
78
0X03) Read the Holding Registers (Readback Aos)
80
0X04) Read the Input Registers (Read Ais)
82
0X05) Force a Single Coil (Write DO)
84
0X06) Preset a Single Register (Write AO)
86
0X0F) Force Multiple Coils (Write Dos)
88
0X10) Preset Multiple Registers (Write Aos)
90
Modbus Register Table
92
Common Functions
92
Specific Functions
94
Advertisement
ICP DAS USA ET-2255 User Manual (93 pages)
Ethernet I/O Module
Brand:
ICP DAS USA
| Category:
Control Unit
| Size: 6.48 MB
Table of Contents
Table of Contents
2
1 Introduction
4
Features
4
2 Hardware Information
7
Appearance
7
Specification
9
System Specification
9
I/O Specification
10
2242
10
2251
10
2254
11
2255
12
2260
13
Pin Assignments
14
2242
14
2251
14
2254
15
2255
15
2260
16
Wiring Connections
17
Input Wiring
17
Output Wiring
19
Wiring to the Connector
20
Dimensions
21
3 Getting Started
22
Configuring the Boot Mode
22
Connecting the Power and the Host Pc
23
Configuring the Network Settings
24
Modbus Tcp Testing
26
4 Web Configuration
28
Logging in to the Web Server
28
Home
30
Network
32
Network and Miscellaneous Settings
32
IP Address Configuration
33
Dynamic Configuration
34
Manual Configuration
35
General Settings
36
Restore Factory Defaults
37
Firmware Update
39
I/O Settings
40
Network and Miscellaneous Settings
40
DO Control
40
DI/DO Configuration
41
Pwm
44
Additional Settings
44
PWM Configuration
44
Pair Connection
46
Status & Configuration
46
I/O Pair-Connection Settings
46
Filter
49
Network and Miscellaneous Settings
49
Filter Settings
49
Monitor
51
Change Password
52
Logout
53
5 I/O Pair Connection Applications
54
One Module Polling the Remote DI/DO (1-To-1, Polling Mode)
54
Polling Mode
56
Push Mode
57
Two Modules Pushing the Local DI to each Other (1-To-1, Push Mode)
58
Several Modules Polling the Remote DI (M-To-1) (Polling Mode)
61
Several Modules Pushing the Local DI (M-To-1) (Push Mode)
64
6 Modbus Information
67
What Is Modbus Tcp/Ip
67
Modbus Message Structure
68
0X01) Read the Status of the Coils (Readback Dos)
71
0X02) Read the Status of the Input (Read Dis)
73
0X03) Read the Holding Registers (Readback Aos)
75
0X04) Read the Input Registers (Read Ais)
77
0X05) Force a Single Coil (Write DO)
79
0X06) Preset a Single Register (Write AO)
81
0X0F) Force Multiple Coils (Write Dos)
83
0X10) Preset Multiple Registers (Write Aos)
85
Modbus Register Table
87
Common Functions
87
Specific Functions
89
ICP DAS USA ET-2255 Quick Start Manual (8 pages)
Brand:
ICP DAS USA
| Category:
Control Unit
| Size: 1.08 MB
ICP DAS USA ET-2255 Quick Start Manual (6 pages)
Brand:
ICP DAS USA
| Category:
Network Hardware
| Size: 1.11 MB
Advertisement
Related Products
ICP DAS USA ET-2200 Series
ICP DAS USA ET-2242
ICP DAS USA ET-2251
ICP DAS USA ET-2254
ICP DAS USA ET-2260
ICP DAS USA ET-7H16M Series
ICP DAS USA ET-87P4
ICP DAS USA ET-87P8
ICP DAS USA ET-7015
ICP DAS USA ET-7018Z
ICP DAS USA Categories
Control Unit
I/O Systems
Controller
Media Converter
PCI Card
More ICP DAS USA Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL