Sign In
Upload
Manuals
Brands
Dionex Manuals
Laboratory Equipment
ICS-900
Dionex ICS-900 Ion Chromatography System Manuals
Manuals and User Guides for Dionex ICS-900 Ion Chromatography System. We have
1
Dionex ICS-900 Ion Chromatography System manual available for free PDF download: Operator's Manual
Dionex ICS-900 Operator's Manual (142 pages)
Ion Chromatography System
Brand:
Dionex
| Category:
Laboratory Equipment
| Size: 7 MB
Table of Contents
Table of Contents
3
1 Introduction
9
Overview of the ICS-900
9
The ICS-900 Operator's Manual
10
Overview
10
Safety and Regulatory Information
11
Safety Messages and Notes
11
Safety Symbols
13
Declaration of Conformity
14
2 Description
15
Operating Features
15
Front Door and Top Cover
15
Component Mounting Panel
17
Rear Panel
19
Fluid Schematic
22
System Component Details
24
Pump
24
Pressure Transducer
25
Injection Valve with Sample Loop
26
MMS 300 Micromembrane Suppressor
27
Displacement Chemical Regeneration (DCR)
28
Conductivity Cell and DS5 Detection Stabilizer
29
Chromeleon and Chromeleon Xpress Software
31
The Panel Tabset
31
Software Control Modes
32
System Wellness and Predictive Performance
33
3 Operation and Maintenance
35
Operation Overview
35
Turning on the ICS-900 Power
36
Connecting to Chromeleon or Chromeleon Xpress
36
Preparing the Eluent
37
Preparing the Regenerant
38
Priming the Pump
40
Equilibrating the System
43
Verifying Operational Status
43
Configuring Standby Mode
44
Preparing Samples
45
Collecting and Storing
45
Pretreating
45
Diluting
46
Processing Samples
47
Overview
47
Manually Processing Samples
48
Automatically Processing Samples (Batch Processing)
50
Loading and Injecting Samples with an Autosampler
52
Loading and Injecting Samples with a Syringe
54
Example Chromeleon Commands for Loading and Injecting Samples
56
Maintenance
57
4 Troubleshooting
59
Alarms and Error Conditions
59
Ics-900 Operator's Manual
60
Flow Rate Calibration Error
61
Load/Inject Valve Error
61
Module Data Buffer Overflow. Data May Have Been Lost
62
Pump Motor Lost Control
62
Pump Pressure Hardware Error
62
Pump Pressure Slope Calibration Error
63
Remaining Eluent below 200 Ml
63
The System Pressure Has Exceeded the High Pressure Limit
64
The System Pressure Is below the Low Pressure Limit
64
To Troubleshoot
64
Liquid Leaks
65
Pump Difficult to Prime or Loses Prime
66
Pump Does Not Start
67
No Flow
67
Erratic Flow/Pressure Reading
67
Excessive System Backpressure
68
Peak "Ghosting
68
Nonreproducible Peak Height or Retention Time
69
Abnormal Retention Time or Selectivity
69
No Detector Response
70
High Detector Output
70
Baseline Noise or Drift
71
5 Service
73
Diagnostics and Calibrations
73
Opening the Wellness Panel
73
Wellness Panel Features
75
Calibrating the Pressure Transducer
77
Calibrating the Cell
78
Calibrating the Flow Rate
80
Replacing Tubing and Fittings
81
Isolating a Restriction in the Liquid Plumbing
82
Eluent in
83
Cleaning Eluent Bottles
84
Changing the Sample Loop
84
Cleaning and Replacing Pump Check Valves
85
Replacing a Pump Piston Seal and Backup Seal
88
Replacing a Pump Piston
94
Replacing the Waste Valve Seal
95
Rebuilding the Injection Valve
96
Replacing the Conductivity Cell
98
Eluent out
98
Replacing the Suppressor
99
Changing the Main Power Fuses
100
A • Specifications
101
Electrical
101
Physical
101
Environmental
101
Front and Rear Panel Leds
102
Pump
102
Injection Valve
103
Suppressors
103
A.6 Injection Valve
103
Column Heater/Thermostat
104
Conductivity Detector and Flow Cell
104
Autosampler
105
System Software
106
B • Reordering Information
107
C • TTL and Relay Control
109
Connecting a TTL or Relay
110
Selecting TTL Input Control Modes and Functions
111
Configuring Relay Output 1 or 2 to Respond to the Pump Flow
114
Controlling TTL and Relay Outputs
116
Controlling an AS40 Automated Sampler with a Relay
118
D • Faq
121
How Do I Connect to an Autosampler
121
How Often Should I Perform Calibrations
121
Why Are the Retention Times Moving
121
How Do I Adjust Retention Times
122
When Should I Remake Standards
122
When Should I Remake Eluents
122
How Do I Start Chromeleon or Chromeleon Xpress
122
How Do I Back up Data
122
How Do I Delete Data
122
How Do I Shut off the System
123
How Do I Store Columns
123
How Do I Know When a Column Is Dirty
123
How Do I Clean a Column
123
Why Is the Conductivity High
123
E • Introduction to Ion Chromatography (IC)
125
F • Glossary
127
Index
133
Advertisement
Advertisement
Related Products
Dionex ICS-90
Dionex ICS-2100
Dionex ICS-3000
Dionex ICS-1000
Dionex ICS-1100
Dionex ICS-1600
Dionex AMMS ICE 300
Dionex ICS-6000
Dionex IonPac TCC Series
Dionex 043185
Dionex Categories
Laboratory Equipment
Measuring Instruments
Analytical Instruments
Security Sensors
Water Pump
More Dionex Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL