Sign In
Upload
Manuals
Brands
Covidien Manuals
Medical Equipment
ForceTriad
Covidien ForceTriad Manuals
Manuals and User Guides for Covidien ForceTriad. We have
3
Covidien ForceTriad manuals available for free PDF download: Service Manual, User Manual, Quick Reference Card
Covidien ForceTriad Service Manual (212 pages)
Energy Platform
Brand:
Covidien
| Category:
Medical Equipment
| Size: 10.81 MB
Table of Contents
Conventions Used in this Guide
4
Preface
4
Limited Warranty
5
Software License
6
Table of Contents
11
Chapter 1. Overview and General Features
17
Introduction
18
Forcetriad Energy Platform Front Panel
19
Forcetriad Energy Platform Back Panel
20
System Conventions
21
Touchscreens
21
Common Symbols
21
Power Modes
23
Monopolar Modes
23
Bipolar Modes
24
Ligasure Mode
25
Chapter 2. Patient and Operating Room Safety
27
General
28
Setting up the System
28
Fire/Explosion Hazard
30
Forcetriad Energy Platform
31
Active Instruments
31
Implanted Electronic Devices (Ieds)
32
After Surgery
32
Monopolar
33
Patient Return Electrodes
33
Inadvertent Radio Frequency (RF) Burns
34
Laparoscopic Procedures
35
Bipolar
36
Ligasure
36
Ligasure in Laparoscopic Procedures
37
Servicing
37
Shunt Cords
37
Conductive Fluid in the Surgical Site
38
Chapter 3. Principles of Operation
39
Block Diagram
40
Functional Overview
42
Tissuefect Tissue Sensing Technology
42
REM Contact Quality Monitoring System
42
High-Voltage DC (HVDC PCBA) Power Supply Principles
43
RF PCBA Principles of Operation
44
Rem
44
Autobipolar
44
Leakage Current Monitor
44
Sensor Circuit
45
Steering Relay PCBA Principles of Operation
46
Circuit Descriptions for the Forcetriad Display PCBA
47
Hotlink Transceiver U1
47
Liquid Crystal Display (LCD) Driver Inside the FPGA U28
47
Barcode Driver
48
Power Supply
48
Footswitch/Audio PCBA Circuitry Description
48
Overview
48
Power Supplies
49
Communications
49
Audio Data
49
Footswitch Data
50
Expansion Port DAC Data
50
DAC Amplifier
50
Isolated Footswitch and Expansion Port Circuitry
50
Controller PCBA Principles of Operation
50
Host Processor
51
Digital Signal Processor (DSP) Controlled Data Converters
51
Interface Control Logic PLD
52
Data Converters
52
External Peripherals
52
Chapter 4. Technical Specifications
53
Performance Characteristics
54
General
54
Dimensions and Weight
54
Operating Parameters
55
Transport and Storage
55
Internal Memory
55
Activation Tone
56
Alarm Tone
56
REM Contact Quality Monitor
57
Autobipolar
57
Duty Cycle
60
Low-Frequency (50/60 Hz) Leakage Current
60
High-Frequency (RF) Leakage Current
60
Input Power
61
Power Cord Specification
61
Input Frequency
62
Input Current
62
Backup Power
62
Equipotential Ground Connection
62
ECG Blanking
62
Standards and IEC Classifications
63
Symbols
64
Class I Equipment (IEC 60601-1)
65
Type CF Equipment (IEC 60601-1)/Defibrillator Proof
65
Liquid Spillage (IEC 60601-2-2 Clause 44.3)
65
Voltage Transients (Emergency System Mains Transfer)
65
Electromagnetic Compatibility
65
Iec 60601-2-2)
65
Output Characteristics
71
Maximum Output for Bipolar, Monopolar, and Ligasure
71
Modes
71
Available Power Settings in Watts
72
Output Waveforms
75
Output Power Vs. Resistance Graphs
76
Monopolar Graphs
76
Bipolar Graphs
84
Bipolar Standard
85
Ligasure
89
Chapter 5. System Setup
91
Setup
92
Before Startup
92
Powering up the Forcetriad Energy Platform
92
System Functions
93
Adjusting Display Brightness
93
Activation Log
93
Service Display
93
Restore
93
Setup
94
Features Menu
95
Demo Mode
99
Chapter 6. Setup, Tests, and Adjustments
101
Setting up the Forcetriad Energy Platform
102
Calibrating the Forcetriad Energy Platform
104
Periodic Safety Check (Routine Maintenance)
109
Recommended Test Equipment
111
Inspecting the System and Accessories
112
Inspecting the Internal Components
113
Testing the System
115
Enable Demo Mode
115
Entering Debug Mode
116
Testing the Low-Voltage Power Supply
117
Verifying the Audio
117
Verifying REM Function
118
Verifying Autobipolar Mode
118
Verifying Cross Coupling
119
Confirming Power Delivery at Receptacle
121
Verifying Power Output
125
Checking High-Frequency Leakage Current
128
Safety Testing in Accordance with IEC601
129
Checking Low-Frequency Leakage Current
130
Ground Bond Testing
131
Docking to Valleylab Exchange
131
Preventive Maintenance Check Sheet
132
Chapter 7. Troubleshooting
141
Inspecting the Forcetriad Energy Platform
142
Responding to System Errors
142
System-Error Descriptions
143
Non-Recoverable Error Descriptions
143
Chapter 8. Replacement Procedures
169
Removing and Reinstalling the Front Panel
170
Fuse Replacement
172
Battery Replacement
173
Low-Voltage Power Supply (LVPS) Replacement
174
Footswitch/Audio PCBA Replacement
176
Controller PCBA Replacement
178
High-Voltage DC (HVDC) PCBA Replacement
180
RF PCBA Replacement
182
Steering-Relay PCBA Replacement
184
Display PCBA Replacement
186
Barcode Scanner Replacement
188
Output Receptacle Replacement
190
Barcode-Scanner Cables
193
System Displays
194
System Display Cables
196
System Fans
198
Scan Stand Label
200
Chapter 9. Maintenance and Repair
203
Responsibility of the Manufacturer
204
Routine Maintenance and Periodic Safety Checks
204
Cleaning
205
Product Service
205
Returning the System for Service
205
Adjustment to Factory Specification (Calibration)
206
Software Upgrades
206
Covidien Technical Service
206
Chapter 10. Service Parts
207
Ordering Replacement Parts
208
Replacement Components
209
Replacing Cable Assemblies
210
Advertisement
Covidien ForceTriad User Manual (134 pages)
Energy Platform
Brand:
Covidien
| Category:
Medical Equipment
| Size: 2.78 MB
Table of Contents
Conventions Used in this Guide
4
Preface
4
Limited Warranty
5
Software License
7
Table of Contents
11
Chapter 1. Overview and General Features
15
Forcetriad Energy Platform Front Panel
16
Introduction
17
Indications for Use
17
System Conventions
18
Touchscreens
18
Common Symbols
18
Power Modes
20
Monopolar Modes
21
Bipolar Modes
21
Ligasure Mode
22
Chapter 2. Patient and Operating Room Safety
23
General
24
Setting up the System
24
Fire/Explosion Hazard
26
Energy Platform
27
Active Instruments
27
Implanted Electronic Devices (Ieds)
28
After Surgery
28
Monopolar
29
Patient Return Electrodes
29
Inadvertent Radio Frequency (RF) Burns
30
Laparoscopic Procedures
31
Bipolar
32
Ligasure
32
Ligasure in Laparoscopic Procedures
33
Servicing
33
Shunt Cords
33
Conductive Fluid in the Surgical Site
34
Chapter 3. System Setup
35
Setup
36
Before Startup
36
Powering up the Forcetriad Energy Platform
36
System Functions
36
Adjusting Display Brightness
36
Activation Log
36
Service Display
37
Restore
37
Setup
37
Demo Mode
43
Chapter 4. Monopolar Function
45
Front Panel Monopolar Features
46
Rear Panel Monopolar Features
47
Monopolar Quick Setup Instructions
48
Monopolar Function Overview
48
Monopolar Power Output Modes
48
Monopolar Footswitch
49
Standard Monopolar Footswitching
49
Software-Enabled Monopolar 1 Footswitching
50
Return Electrodes - REM Contact Quality Monitoring System
51
Patient Return Electrode Considerations
51
How the REM System Works
52
Patient Return Electrode Setup
53
Monopolar Electrodes
54
Standard Monopolar Mode Functionality
55
Valleylab Mode Functionality
56
Using a Valleylab Mode Instrument
57
Manual Power Control Functionality
58
Accessory Port Functionality
59
Chapter 5. Bipolar Surgery
61
Front Panel Bipolar Features
62
Rear Panel Bipolar Features
63
Bipolar Quick Setup Instructions
63
Bipolar Function Overview
64
Bipolar Power Output Modes
64
Footswitch
64
Bipolar Electrode Function
65
Autobipolar Function
66
Activation Impedance
66
Chapter 6. Ligasure Tissue Fusion
69
Front Panel Ligasure Features
70
Rear Panel Ligasure Features
71
Ligasure Quick Setup Instructions
71
Ligasure Function Overview
72
Ligasure Receptacles
73
Footswitch
74
Start System
74
Ligasure Instruments
75
Reusable-Instrument Assembly
75
Connecting Ligasure Instruments to the Energy Platform
75
Ligasure Settings
77
Changing the Energy-Delivery Setting
77
Activating the Ligasure Instrument
77
Alert Situations
78
After Surgery
79
Disconnect the Instruments
79
Reprocessing Instruments
80
Chapter 7. Troubleshooting
83
General Troubleshooting Guidelines
84
REM Alarms
84
Correcting a REM-Alarm Condition
84
Correcting Malfunctions
85
System Alarms
90
Chapter 8. Maintenance and Repair
95
Responsibility of the Manufacturer
96
Routine Maintenance and Periodic Safety Checks
96
Cleaning
97
Product Service
97
Returning the Energy Platform for Service
97
Adjustment to Factory Specification (Calibration)
98
Software Upgrades
98
Covidien Technical Service
98
Chapter 9. Technical Specifications
99
Performance Characteristics
100
General
100
Dimensions and Weight
100
Operating Parameters
101
Transport and Storage
101
Internal Memory
101
Activation Tone
102
Alarm Tone
102
REM Contact Quality Monitor
103
Autobipolar
104
Duty Cycle
106
Low Frequency (50/60 Hz) Leakage Current
106
High Frequency (RF) Leakage Current
106
Input Power
107
Power Cord Specification
107
Input Frequency
107
Input Current
108
Backup Power
108
Equipotential Ground Connection
108
ECG Blanking
108
Standards and IEC Classifications
109
Symbols
110
Class I Equipment (IEC 60601-1)
111
Type CF Equipment (IEC 60601-1)/Defibrillator Proof
111
Liquid Spillage
111
IEC 60601-2-2:2009 Clause 201.11.6.3)
111
Voltage Transients
111
Transfer)
111
Electromagnetic Compatibility
112
And IEC 60601-2-2)
112
Output Characteristics
113
Maximum Output for Bipolar, Monopolar, and Ligasure
113
Modes
113
Available Power Settings in Watts
114
Output Waveforms
119
Output Power Vs. Resistance Graphs
120
Monopolar Graphs
120
Bipolar Graphs
127
Covidien ForceTriad Quick Reference Card (28 pages)
Energy Platform
Brand:
Covidien
| Category:
Medical Equipment
| Size: 2 MB
Table of Contents
Standard Monopolar Footswitching
7
Software Enabled Monopolar 1 Footswitching
8
Autobipolar Function
14
Troubleshooting
21
Advertisement
Advertisement
Related Products
Covidien Force FX
Covidien Force FX-C
Covidien Filac 3000 EZ
Covidien Filac 3000 EZA
Covidien Valleylab FT10
Covidien DAR
Covidien Endo Stitch
Covidien HawkOne H1-LS-INT
Covidien HawkOne H1-LX-INT
Covidien HawkOne LS
Covidien Categories
Medical Equipment
Accessories
Thermometer
Measuring Instruments
Water Pump
More Covidien Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL