Sign In
Upload
Manuals
Brands
AUMA Manuals
Controller
SAEx 40.1
AUMA SAEx 40.1 Manuals
Manuals and User Guides for AUMA SAEx 40.1. We have
3
AUMA SAEx 40.1 manuals available for free PDF download: Operation Instructions Manual, Manual
AUMA SAEx 40.1 Operation Instructions Manual (112 pages)
Multi-turn actuators, Control unit - electromechanical with actuator controls, on wall bracket
Brand:
AUMA
| Category:
Controller
| Size: 3.16 MB
Table of Contents
Table of Contents
2
1 Safety Instructions
6
Prerequisites for the Safe Handling of the Product
6
Range of Application
6
Warnings and Notes
7
References and Symbols
7
2 Identification
9
Short Description
9
Name Plate
10
3 Transport and Storage
15
Transport
15
Storage
16
4 Assembly
17
Mounting Position
17
Handwheel Fitting
17
Multi-Turn Actuator: Mount to Valve/Gearbox
18
Design of Output Drive Type a
18
Stem Nut for Output Drive Type A: Finish Machining
18
Multi-Turn Actuator with Output Drive Type A: Mount
20
Design of Output Drive Types B and E
21
Multi-Turn Actuator with Output Drive Type B: Mount
21
Accessories for Assembly
22
Stem Protection Tube for Rising Valve Stem
22
5 Electrical Connection
24
Basic Information
24
Cable Installation for Wall Bracket and Control Box
26
Electrical Connection of Actuator
28
Motor Connection
28
Motor Connection Compartment: Open
28
Motor Cables: Connect
29
Motor Connection Compartment: Close
30
Electrical Connection (K/KR)
30
Terminal Compartment: Open
30
Cable Connection
31
Terminal Compartment: Close
32
Electrical Connection of Actuator Controls
33
KP/KPH Electrical Connection
33
Terminal Compartment: Open
34
Cable Connection
35
Terminal Compartment: Close
36
KES Electrical Connection
37
Terminal Compartment: Open
38
Cable Connection
39
Terminal Compartment: Close
40
KT/KM Electrical Connection
41
Terminal Compartment: Open
42
Cable Connection
43
Terminal Compartment: Close
45
External Earth Connection
46
Accessories for Electrical Connection
47
Parking Frame
47
Operation
48
Manual Operation
48
Engage Manual Operation
48
Manual Operation: Disengage
49
Motor Operation
49
Operating the Actuator from Local Controls
49
Actuator Operation from Remote
50
Menu Navigation Via Push Buttons (for Settings and Indications)
50
Menu Layout and Navigation
51
User Level, Password
52
Password Entry
53
Password Change
53
Language in the Display
54
Language Change
54
Indications
56
Indications During Commissioning
56
Indications in the Display
56
Feedback Indications from Actuator and Valve
57
Status Indications According to AUMA Classification
59
Status Indications According to NAMUR Recommendation
60
Indication Lights of Local Controls
62
Optional Indications
63
Mechanical Position Indication Via Indicator Mark
63
Signals (Output Signals)
64
Status Signals Via Output Contacts (Digital Outputs)
64
Assignment of Outputs
64
Coding the Outputs
64
Analogue Signals (Analogue Outputs)
64
Commissioning (Basic Settings)
65
Heat-Up Time for Low Temperature Version
65
Type of Seating: Set
65
Switch Compartment: Open
66
Torque Switching: Set
67
Limit Switching: Set
67
End Position CLOSED (Black Section): Set
68
End Position OPEN (White Section): Set
68
Test Run
69
Direction of Rotation at Mechanical Position Indicator: Check
69
Direction of Rotation at Hollow Shaft/Stem: Check
70
Limit Switching: Check
70
Reference Operation Position Feedback: Perform
71
Switch Compartment: Close
71
Commissioning (Optional Equipment Settings)
72
Potentiometer
72
Potentiometer: Set
72
RWG Electronic Position Transmitter
72
Measuring Range: Set
73
Intermediate Positions: Set
74
Running Direction CLOSE (Black Section): Set
74
Running Direction OPEN (White Section): Set
74
Mechanical Position Indicator: Set
75
Corrective Action
76
Faults During Commissioning
76
Fault Indications and Warning Indications
76
Fuses
80
Fuses Within the Actuator Controls
80
Fuse Replacement
81
Replace Fuses
81
Test/Replace Fuses
82
Fuses Within the Control Box
82
Motor Protection (Thermal Monitoring)
83
Servicing and Maintenance
85
Preventive Measures for Servicing and Safe Operation
85
Disconnection from the Mains
86
Disconnection from the Mains with KP/KPH and KES Electrical Connection
86
Disconnection from the Mains with KT/KM Electrical Connection
87
Maintenance
88
Disposal and Recycling
88
Technical Data
90
Technical Data Multi-Turn Actuators
90
Technical Data Actuator Controls
93
Technical Data Control Box
97
Spare Parts
98
Multi-Turn Actuators Saex
98
Saex 40.1/Sarex 25.1
98
Actuator Controls Acexc 01.2 KP/KPH
100
Actuator Controls AUMATIC Acexc 01.2 KES
102
Actuator Controls Acexc 01.2 KT/KM
104
Exc Wall Bracket
106
Advertisement
AUMA SAEx 40.1 Operation Instructions Manual (56 pages)
Multi-turn actuators
Brand:
AUMA
| Category:
Controller
| Size: 1.94 MB
Table of Contents
Table of Contents
2
Safety Instructions
4
Prerequisites for the Safe Handling of the Product
4
Range of Application
5
Warnings and Notes
6
References and Symbols
6
Short Description
7
Name Plate
8
Transport and Storage
11
Transport
11
Storage
12
Assembly
13
Mounting Position
13
Fit Handwheel
13
Mount Actuator to Valve
14
Overview of Output Drive Types
14
Output Drive Type a
15
Output Drive Types B/C/D/E
19
Accessories for Assembly
20
Stem Protection Tube for Rising Valve Stem
20
Electrical Connection
22
Basic Information
22
Motor Connection
23
Open Motor Connection Compartment
24
Connect Motor Cables
24
Close Motor Connection Compartment
25
K/KR Electrical Connection
26
Open Terminal Compartment
26
Cable Connection
27
Close Terminal Compartment
28
External Earth Connection
28
Operation
30
Manual Operation
30
Manual Valve Operation
30
Motor Operation
31
Indications (Option)
32
Mechanical Position Indication Via Indicator Mark
32
Signals (Output Signals)
33
Feedback Signals from Actuator
33
Commissioning (Basic Settings)
34
Open Switch Compartment
34
Set Torque Switching
34
Set Limit Switching
35
Set End Position CLOSED (Black Section)
35
Set End Position OPEN (White Section)
36
Test Run
36
Check Direction of Rotation at Mechanical Position Indicator
36
Check Direction of Rotation at Hollow Shaft/Stem
37
Check Limit Switching
38
Close Switch Compartment
38
Commissioning (Optional Equipment Settings)
39
Potentiometer
39
Potentiometer Setting
39
RWG Electronic Position Transmitter
39
Set Measuring Range
40
Set Intermediate Positions
41
Set Running Direction CLOSE (Black Section)
41
Set Running Direction OPEN (White Section)
42
Set Mechanical Position Indicator
42
Corrective Actions
43
Faults During Operation/Commissioning
43
Motor Protection (Thermal Monitoring)
43
Servicing and Maintenance
44
Preventive Measures for Servicing and Safe Operation
44
Maintenance
45
Disposal and Recycling
46
Technical Data
47
Technical Data Multi-Turn Actuators
47
Tightening Torques for Screws
49
Spare Parts List
50
Multi-Turn Actuators Saex 25.1 - Saex 40.1 / Sarex 25.1 - Sarex 30.1
50
Index
52
AUMA SAEx 40.1 Manual (48 pages)
Multi-turn actuators with actuator controls
Brand:
AUMA
| Category:
Controller
| Size: 1.13 MB
Table of Contents
Table of Contents
2
Terminology
4
Abbreviations and Concepts
4
Application and Validity
6
Range of Application
6
Standards
6
Valid Device Types
6
Architecture, Configuration and Applications
7
Architecture (Actuator Sizing)
7
Configuration (Setting)/Version
8
Protection against Uncontrolled Operation (Self-Locking/Brake)
10
Operation Mode (Low/High Demand Mode)
11
Further Notes and Indications on Architecture
11
Applications (Environmental Conditions)
11
Safety Instrumented System and Safety Functions
12
Safety Instrumented System Including an Actuator
12
Safety Functions
12
Safe Inputs and Outputs
13
Redundant System Architecture
13
Examples of Applications
14
System Representation
16
Installation, Commissioning and Operation
17
Installation
17
Commissioning
19
Operation
19
Lifetime
20
Decommissioning
20
Indications on Display
21
Status Indications on SIL Functions
21
SIL Configuration Warning
22
Backlight
22
Signals
23
Signals Via SIL Module
23
SIL - Fault Signal Via the Standards Actuator Controls Display (for Troubleshooting Support)
23
Status Signals Via Output Contacts (Digital Outputs) of Standard Actuator Controls
24
Signals Via Fieldbus of Standard Actuator Controls
25
Tests and Maintenance
26
Safety Equipment: Check
26
Actuator Monitoring for ESD Safety Function
26
Partial Valve Stroke Test (PVST): Execute
26
Actuator Monitoring for Safe End Position Feedback" Safety Function
28
Proof Test (Verification of Safe Actuator Function)
28
Preliminary Tests
29
Check Safe ESD Safety Operation Safe OPENING/CLOSING
29
Check SIL Fault Signal Actuator Monitoring
30
Check Safe ESD Reaction for Motor Protection (Thermal Fault)" Signals
31
Check Safe ESD Reaction to Limit Seating with Overload Protection
32
Check Safe ESD Reaction to "Forced Limit Seating in End Position" (Limit Evaluation)
33
Check Safe ESD Reaction to "Forced Torque Seating in End Position
35
Check Safe ESD Reaction for no Seating" (no Evaluation of Limit and Torque)
35
Check Safe STOP Function
37
Check Combination of Safe ESD and Safe STOP Function
37
Check Safe End Position Signal" Safety Function
38
Maintenance
39
Safety-Related Figures
40
Determination of the Safety-Related Figures
40
Specific Figures for AC 01.2 Actuator Controls in 22X or 22Y Version with Actuators of the SA .1
41
Type Range
41
SIL Declaration of Incorporation
43
Index
47
Advertisement
Advertisement
Related Products
AUMA SAEx 07.6
AUMA SAEx 10.2
AUMA SAEx 14.6
AUMA SAEx 16.2
AUMA SAEx 14.2
AUMA SAExC 07.1
AUMA SAExC 10.1
AUMA SAEx Series
AUMA SAEx 35.1
AUMA SAEx 07.2 KT/KM
AUMA Categories
Controller
Industrial Equipment
Control Unit
Control Systems
Outboard Motor
More AUMA Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL