Sign In
Upload
Manuals
Brands
Alpha innotec Manuals
Control Unit
Luxtronik
Alpha innotec Luxtronik Manuals
Manuals and User Guides for Alpha innotec Luxtronik. We have
6
Alpha innotec Luxtronik manuals available for free PDF download: Operating Manual, Instruction Manual, Operating Instructions Manual
Alpha-InnoTec Luxtronik Operating Manual (52 pages)
Heating- and Heat Pump Control
Brand:
Alpha-InnoTec
| Category:
Heat Pump Accessories
| Size: 5 MB
Table of Contents
Please Read First
2
Symbols
2
Table of Contents
3
Scope of Delivery
4
Installed Control Scope of Supply
4
Wall Control Scope of Supply
4
Montage
4
Assembly of the Installed Control
4
Assembly of the Wall Control
4
Air/Water Outdoor Units Standard
4
Air/Water Outdoor Units Professional (LWP)
4
Electrical Connections
5
Installation of the Wall-Control
5
Air/Water Outdoor Units Standard
5
Air/Water Outdoor Units Professional (LWP)
5
Control Unit Variants
7
Variants of the Motherboard
7
Assembly and Installation of Sensors
8
External Sensor
8
Hot Water Sensor
8
External Return Flow Sensor
9
Dismantling
9
Softwareupdate / -Downgrade
9
Switching on / Commissioning
9
Startup Guide
11
Fix Startup Parameters
11
Reset Startup Parameters
12
Emergency Mode
12
Program Area "Cooling
13
Select Program Aerea
13
Setting the Mode of Operation "Cooling
13
Set Temperatures
14
Set Parameters
14
Cooling Based on Set Temperature or Depending on Outdoor Temperature
15
Enable Active Cooling
15
Program Area "Service
16
Select Program Area
16
Query Information
16
Query Temperatures
16
Query Inputs
17
Query Outputs
17
Query Elapsed Times
18
Query Operating Hours
18
Query Error Memory
18
Query Outages
18
Query the Facility Status
19
Query Heat Quantity
19
Query Building Services Management System (BMS)
19
Query Smart
20
Query Infolog
20
Query Inverter
20
Query Eventlog
21
Making Settings
21
Determine Data Access
21
Calling up Preset Program
22
Determining Temperatures
22
Hot Gas Utilisation / Desuperheater
24
Determining Priorities
24
Determining System Setting
24
Ventilating the System
28
Fix Startup Parameters
29
Back up Error Memory Externally
29
Efficiency Pump
29
RBE - Room Control Unit
30
Additional Heat Generator
30
Inverter
31
Flexconfig
31
Silent Mode
32
Pump Flow
32
Smart
33
Smart Grid
33
Operating States
33
Set Decrease / Increase
34
Terminal Diagrams Smart Grid
34
Selecting Language of the Screen Display
35
Determining Date and Time
35
Screed Heating Program
35
Setting Temperatures and Time Intervals
35
Starting Screed Heating Program
36
Manually Terminating Screed Heating Program
37
Heatpump Configuration
37
Startup Guide
38
Reset Startup Parameters
38
Data Logger
38
Control Panel
38
Adjusting the Contrast of the Control Unit Display
38
Web Server
38
Remote Maintenance
38
Error Diagnosis / Error Messages
39
Acknowledging a Fault
44
Flashing Codes on Controller Board
44
Technical Data
44
Installation
44
Outputs
44
Inputs
44
Connections
44
Interfaces
44
Protection Class
44
Temperature Sensor Characteristic Curve
44
Overview: Defrost Cycle, Air Defrost, Flow Max
45
Sensor Measuring Range
45
System Setting During Commissioning
46
Abbreviations (Selection)
50
Advertisement
alpha innotec Luxtronik Operating Instructions Manual (40 pages)
Heating - and Operating Instructions Heat Pump Control
Brand:
alpha innotec
| Category:
Control Unit
| Size: 3 MB
Table of Contents
Please Read First
2
Symbols
2
Table of Contents
3
Functioning of the Heating and Heat Pump Regulator
5
Intended Use
5
Exclusion of Liability
5
Safety
5
Care of the Unit
6
Maintenance of the Unit
6
Customer Service
6
Warranty / Guarantee
6
Disposal
6
The Control Unit
7
Status Display
7
Screen
7
Rotary Pushbutton
7
Error Messages
8
Language of the Screen Display
8
Determining Date and Time
9
Adjusting the Contrast of the Control Element Display
9
Menu Display
9
Standard Screen "Heating
10
Switch to Standard Screen "Domestic Hot Water
10
Standard Screen "Domestic Hot Water
10
Switch to the Navigation Screen
10
The Navigation Screen
11
Basic Display
11
Display of Further Program Areas
11
Special Programs Display
11
Program Area "Information and Quick Setting
13
Standard Screen
10
The Menu "Quick Setting: Heating
13
Setting the Heating Mode of Operation
13
Setting the Hot Water Return Flow Temperature
14
Setting the Time Programs of the Heating Circle
14
Select Program Area
13
Same Switching Times on All Days of the Week
14
Different Switching Times During the Week and on Weekends
15
Different Switching Times for each Day
15
The Menu "Info + Setting Domestic Hot Water
16
Setting the Domestic Hot Water Mode of Operation
17
Setting the Domestic Hot Water Temperature
17
Setting the Domestic Hot Water Off-Times
18
Care Programs
18
The Menu "Info + Setting Complete System
18
Program Area "Heating
20
Setting the Mode of Operation "Heating
20
Select Program Area
20
Temperature-Setting
20
Change Temperature
20
Setting the Heating Curve
20
Setting the Heating Curves of the Heating Circle
21
Select Table "Heating Curve End Point
21
Determine the Heating Curve End Point
22
Select the Table Field Difference Temperature (Lowered in Night Mode)
22
Equalisation of the Heating Curve End Point with the Regional Standard Dimensioning Temperature
22
Setting the Heating Curves of Mixing Circle 1
23
Setting a Fixed Temperature
23
Fixed Temperature Heating Curves
24
Fixed Temperature Mixing Circle 1
24
Time Program Heating
24
Heating Limit
24
Program Area "Hot Water
25
Select Program Area
25
Domestic Hot Water Preparation
25
Setting the Mode of Operation
25
Set the Domestic Hot Water Temperature
25
Hot Water Temperature Without Reheating (Factory Setting)
25
Hot Water Temperature with Reheating
26
Time Programs "Domestic Hot Water Preparation
26
High-Speed Charge
27
Maintenance Programs
27
Thermal Disinfection
27
Circulation
28
Time Switches
28
Impulse
28
Program Area "Cooling
29
Setting the Mode of Operation "Cooling
29
Select Program Area
29
Setting the Cooling Temperature
30
Set Parameter
30
Program Area "Parallel Connection
31
Select Program Area
33
Ip-Adress
33
Set or Change the IP Address
33
External Return Flow Sensor
34
Setting on the Master Heat Pump
34
Search for the Heatpump Slaves
34
Status of the Master Heat Pump
34
Setting the Heating
35
Program Area "Service
36
Calling up Short Programs
36
Determining Priorities
36
Data Logger
36
Control Panel
37
Web Server
37
DHCP Server
37
DHCP Client
37
Remote Maintenance
38
Switch on the Remote Maintenance Function
38
Adjust the Remote Maintenance Function
38
Check Connection
39
Manual Data Transfer
39
Error Causes with Connection Problems
39
Information on the Remote Maintenance Function
39
Alpha-InnoTec Luxtronik Operating Manual (47 pages)
Heating and Heat Pump Controller part 2
Brand:
Alpha-InnoTec
| Category:
Controller
| Size: 7 MB
Table of Contents
Please Read First
2
Symbols
2
Table of Contents
3
Installation of Sensors, Dismantling
4
Scope of Delivery
4
Installed Control Scope of Supply
4
Wall Control Scope of Supply
4
Montage
4
Installing the Installation Control
4
Assembly of the Wall Control
4
Air/Water Outdoor Units Standard
4
Air/Water Outdoor Units Professional (LWP)
4
Electrical Connections
5
Installation of the Wall-Control
5
Air/Water Outdoor Units Standard
5
Air/Water Outdoor Units Professional (LWP)
5
Control Unit Variants
7
Variants of the Control Board
7
Assembly and Installation of Sensors
8
External Return Flow Sensor
8
Hot Water Sensor
8
Dismantling
9
Removal of the Buffer Battery
9
Softwareupdate / -Downgrade
9
Switching on for the First Time / Commissioning
9
Program Area "Cooling
11
Select Program Aerea
11
Setting the Mode of Operation "Cooling
11
Set Temperatures
12
Set Parameters
12
Cooling Based on Set Temperature or Depending on Outdoor Temperature
13
The Cooling Release Can Take Place Depending on the Outdoor Temperature or after a Fixed Temperature (= Set Temperature)
13
Program Area "Service
14
Select Program Area
14
Query Information
14
Query Inputs
14
Query Temperatures
14
Query Elapsed Times
15
Query Operating Hours
15
Query Outputs
15
Calling up Disconnections
16
Calling up Error Memories
16
Calling up the Machine Status
16
Heat Quantity
16
Making Settings
17
Calling up Short Programs
17
Determine Data Access
17
Determining Temperatures
17
Hot Gas Utilisation / Desuperheater
19
Determining Priorities
20
Determining System Setting
20
Ventilating the System
23
Fix Startup Parameters
24
Efficiency Pump
25
Save Error Memory Externally
25
RBE - Room Control Unit
26
Second Heat Generator
26
Flexconfig
27
Inverter
27
Pump Flow
28
Silent Mode
28
Operating States
29
Set Decrease / Increase
29
Smart Grid
29
Terminal Diagrams Smart Grid
30
Selecting Language of the Screen Display
30
Determining Date and Time
30
Screed Heating Program
31
Setting Temperatures and Time Intervals
31
Starting Screed Heating Program
31
Manually Terminating Screed Heating Program
32
System Configuration
32
Startup Guide
33
Startup Parameter Back
33
Data Logger
34
Control Panel
34
Adjusting the Contrast of the Control Element Display
34
Remote Maintenance
34
Web Server
34
Appendix
35
Appendix Error Diagnosis / Error Messages
35
Acknowledging a Fault
39
Flashing Codes on Controller Board
39
Technical Data
39
Installation
39
Outputs
39
Inputs
39
Connections
39
Interfaces
39
Protection Class
39
Temperature Sensor Characteristic Curve
39
Overview: Defrost Cycle, Air Defrost, Flow Max
40
Sensor Measuring Range
40
System Setting During Commissioning
41
Important Abbreviations
45
Advertisement
Alpha-InnoTec Luxtronik Operating Instructions Manual (36 pages)
Heating- and Heat Pump Control
Brand:
Alpha-InnoTec
| Category:
Controller
| Size: 7 MB
Table of Contents
Please Read First
2
Symbols
2
Table of Contents
3
Functioning of the Heating and Heat Pump Regulator
4
Intended Use
4
Exclusion of Liability
4
Safety
5
Care of the Unit
5
Maintenance of the Unit
5
Contact
5
Warranty / Guarantee
5
Disposal
5
The Control Unit
6
Status Display
6
Screen
6
Rotary Pushbutton
6
Error Messages
7
Language of the Screen Display
7
Enter Digits
7
Determining Date and Time
7
Adjusting the Contrast of the Control Element Display
7
Menu Display
8
Standard Screen
8
Standard Screen "Heating
8
Switch to Standard Screen "Domestic Hot Water
8
Standard Screen "Domestic Hot Water
8
Switch to the Navigation Screen
8
The Navigation Screen
9
Basic Display
9
Display of Further Program Areas
9
Special Programs Display
9
Program Area "Info + Settings
10
Select Program Area
10
The Menu "Info + Settings Heating
10
Setting the Heating Mode of Operation
10
Setting the Time Programs of the Heating Circuit
11
Same Switching Times on All Days of the Week
11
Different Switching Times During the Week and on Weekends
12
Different Switching Times for each Day
13
The Menu "Info + Settings Domestic Hot Water
13
Setting the Domestic Hot Water Mode of Operation
13
Setting the Domestic Hot Water Temperature
14
Setting the Domestic Hot Water Off-Times
14
Maintenance Program
14
The Menu "Info + Setting Complete System
15
Program Area "Heating
16
Setting the Mode of Operation "Heating
16
Select Program Area
16
Temperature-Setting
16
Change Temperature
16
Setting the Heating Curve
16
Setting the Heating Curves of the Heating Circuit
17
Select Table "Heating Curve End Point
17
Determine the Heating Curve End Point
18
Determine the Difference Temperature (Lowered in Night Mode)
18
Equalisation of the Heating Curve End Point with the Regional Standard Dimensioning Temperature
18
Setting the Heating Curves of Mixing Circuit 1
19
Setting a Fixed Temperature
19
Fixed Temperature Heating Circuit
20
Fixed Temperature Mixing Circuit 1
20
Time Program Heating
20
Program Area "Domestic Hot Water
21
Domestic Hot Water Preparation
21
Heating Limit
21
Select Program Area
21
Setting the Mode of Operation
21
Set the Domestic Hot Water Temperature
21
Hot Water Temperature Without Reheating (Factory Setting)
22
Hot Water Temperature with Reheating
22
Time Programs "Domestic Hot Water Preparation
23
High-Speed Charge
23
Maintenance Program
24
Thermal Disinfection
24
Circulation
25
Time Switches
25
Impulse
25
Program Area "Parallel Connection
26
Select Program Area
28
Ip-Adress
28
Set or Change the IP Address
28
External Return Flow Sensor
29
Setting on the Master Heat Pump
29
Search for the Heatpump Slaves
29
Status of the Master Heat Pump
29
Setting the Heating
29
Program Area "Service
31
Calling up Preset Programs
31
Determining Priorities
31
Data Logger
31
Control Panel
32
Web Server
32
DHCP Server
32
DHCP Client
32
Remote Control
33
IP-Address
33
Remote Maintenance
33
Switch on the Remote Maintenance Function
34
Adjust the Remote Maintenance Function
34
Check Connection
34
Manual Data Transfer
35
Error Causes with Connection Problems
35
Information on the Remote Maintenance Function
35
alpha innotec Luxtronik Operating Instructions Manual (44 pages)
Heating- and Heat Pump Control
Brand:
alpha innotec
| Category:
Controller
| Size: 3 MB
Table of Contents
Authorised Service Personnel
2
Please Read First
2
Symbols
2
Table of Contents
3
Installation of Sensors, Dismantling
5
Scope of Delivery
5
Installed Control Scope of Supply
5
Wall Control Scope of Supply, LW169H(A)V
5
Montage
5
Installing the Installation Control
5
Assembly of the Wall Control, LW169H(A)V
5
Electrical Connections
6
Installation of the Wall Control
6
Control Unit Variants
8
Assembly and Installation of Sensors
9
Hot Water Sensor
9
External Return Flow Sensor
9
Dismantling
10
Removal of the Buffer Battery
10
Softwareupdate
10
Commissioning / Switching on for the First Time
10
Smart Grid
12
Adjustable under System Settings
12
Terminal Diagram
12
Program Area "Service
14
Sekect Program Area
14
Query Information
14
Query Temperatures
14
Query Inputs
14
Query Outputs
15
Calling up Timings
15
Query Operating Hours
15
Calling up Error Memories
16
Calling up Disconnections
16
Calling up the Machine Status
16
Heat Quantity
17
Bacnet
17
Making Settings
17
Determine Data Access
17
Calling up Short Programs
18
Determining Temperatures
18
Determining System Setting
20
Determining Priorities
20
Ventilating the System
24
Fix Startup Parameters
25
Energy Efficiency Pump
25
Second Heat Generator
26
Silent Mode, Only Lwcv, Lwv, Lwav, Lwp
26
Hot Gas Utilisation, Only Lwp
27
Selecting Language of the Screen Display
28
Determining Date and Time
28
Setting Temperatures and Time Intervals
28
Screed Heating Program
28
Starting Screed Heating Program
28
Manually Terminating Screed Heating Program
29
System Configuration
29
Startup Guide
30
Startup Guide Parameters Back
30
Data Logger
31
Control Panel
31
Adjusting the Contrast of the Control Element Display
31
Web Server
31
Remote Maintenance
31
Appendix
32
Appendix Error Diagnosis / Error Messages
32
Acknowledging a Fault
35
Flashing Codes on Controller Board
35
Technical Data
36
Installation
36
Outputs
36
Inputs
36
Connections
36
Interfaces
36
Protection Class
36
Temperature Sensor Characteristic Curve
37
Sensor Measuring Range
37
Overview: Defrost Cycle, Air Defrost, Flow Max
38
System Setting During Commissioning
39
Important Abbreviations
42
Alpha-InnoTec Luxtronik Instruction Manual (48 pages)
Heat pump controller
Brand:
Alpha-InnoTec
| Category:
Controller
| Size: 1 MB
Table of Contents
Safety Recommendations
3
Scope of Supply / Accessories
4
Working Mode
4
Wall Fastening
5
Control Circuit Board
8
Operating Device
10
Graphics Display
11
Standard-Screen
12
Hot Water
24
Set Values
34
Technical Details
44
Basic Settings
45
Advertisement
Related Products
Alpha-InnoTec Luxtronik Series
Alpha-InnoTec Luxtronik 2.0
Alpha-InnoTec LUXTRONIK LWAV 82R1
Alpha-InnoTec LUXTRONIK LWAV 82R3
Alpha-InnoTec LUXTRONIK LWAV 122R3
Alpha-InnoTec LUXTRONIK LWDV
Alpha-InnoTec LUXTRONIK Hybrox 5
Alpha-InnoTec LW 250L
Alpha-InnoTec LWD 70A/RX
Alpha-InnoTec PushPull LD 45 O
Alpha innotec Categories
Heat Pump
Heat Pump Accessories
Control Unit
Controller
Fan
More Alpha innotec Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL