Save error memory externally

NOTE
The use of the function requires customer service access.
The internal error memory of the heating and heat pump control-
ler can be copied to a USB stick. This copies a maximum of the last
100 errors that have occurred.

Efficiency pump

The menu is not shown in full here.
Heat distrib. sys
Heat distribution system
radiator
Radiator
floor heat
Underfloor heating
control heating
Control of the heating circulation
pump
Auto
automatic control
Manual
additional menu entries visible:
output heat. nom.
output heat. Min.
Nominal and minimum output of the
heating circulation pump (limitation of
flow noise) manually adjustable
Output heat. max.
Maximum power of heating circulation
pump (only with control heating =
auto visible and adjustable)
We reserve the right to make technical changes | 83055400fUK – Translation of the original instruction manual (2.1) | ait-deutschland GmbH
Control dhw
Control of the domestic hot water
charging pump
Auto
automatic control
Manual
additional menu entry visible:
output dhw.
Manually adjustable output of the
DHW charging pump
output dhw max.
Maximum power of dhw charging
pump (only with control DHW = auto
visible and adjustable)
output cooling
Maximum power of cooling
control VBO
Control of the brine circulation pump
Auto
automatic control
Manual
additional menu entry visible:
output VBO
Power of the brine circulation pump
manually adjustable
output VBO (cooling)
Power of the brine circulating pump
during cooling
dT cooling
Setting the temperature difference
cooling in K
Set bypass valve
Setting the pressure of the bypass
valve
Control signal UWP
current value in % readable
Flow is
current value in l/h readable
Save settings.