2.4 CONNECTING A HEATER TO A HEATING SYSTEM
The heater is placed on the ground, next to the heating source, or in its vicinity. The heating circuit is
connected to marked inputs and outputs of the heater exchanger; deaerating valve is mounted in the
highest place. It is necessary to install a filter into the circuit in order to protect the pumps, the three-way
valve, and backflow flaps, and the exchanger from sedimentation. It is recommended to flush the heating
circuit before the assembly. All wiring connections must be properly insulated from heat. Should the
system work with priority heating of hot service water using a three-way valve, always follow the
installation instructions of the three-way valve's manufacturer.
OKC 300-1000 NTR
OKC 300-1000 NTRR
heated by a gas boiler with two pumps
heated by a gas boiler and solar collectors
controlled by a three-way valve
Figure 8
Figure 9