MAIN SUPPLY CONNECTION

!
WARNING
Read all cautions and warnings on page 1 prior to install this equipment. Particularly, read the follow:
Before connecting the equipment to the power system:
Make sure that the mains voltage and frequency are in the right range (pict.1/a)
• tension from 95V to 260V
• frequency from 50Hz to 60Hz
The power supply connection is shown in pict.1.
1) Do not install the spot close to heat sources. Do not lay the connection cable on the spot when it is warm.
2) This unit must be positioned as to allow its ventilation. Be careful not to occlude the in-out air grilles.
3) The unit must be positioned at least 30cm. from walls or other flammable surfaces.
4) External surface temperature:
• After 5 minutes work; Tc=65°C.
• Once the thermic balance has been obtained; Tc=85°C.
5) The protection screens, the lenses, or the ultraviolet filters must be replaced if they are visibly damaged and their effectiveness
has been reduced, for example, by cracks or deep scratches.
6) Replace the lamp when the lamp life is exhausted (500....1000 hours) to avoid bad performances of the fixture or that the optic
system is damaged by the lamp explosion (see "LAMP'S INSTALLATION" chapter).
7) Clean regularly the in-out air grilles, the lenses and the gobos (see "MAINTENANCE AND PERIODICAL CLEANING" chapter).
8) In case of installation of the spot to a truss, check carefully that the security ring is well fixed with a chain to both truss and unit.
Do not handle the spot by taking it by the bracket, but always by the base with the special handles.
9) Do not install the spot outdoor, directly exposed to rain or moisture.
pict. 1/a
The equipment must be earthed. If this rule is not followed, the warranty will be void.
MAIN FUSE - 6X30 TYPE 12A T (XS700/B)
MAIN FUSE - 2X5X20 TYPE 10A T (XS1200)
... 5 ...
pict. 1
POWER INPUT
L = LIVE (Brown)
N = NEUTRAL (Blue)
= EARTH (Green yellow)