Faq - Daikin FCQ18PVJU Engineeiring Data

Split system air conditioners skyair inverter
Hide thumbs Also See for FCQ18PVJU:
Table of Contents

Advertisement

Specifications
3.3

FAQ

Wall-mounted type
Indoor unit
Model
Outdoor unit
Power supply
1
Cooling capacity
2
Heating capacity
Indoor unit
Color
Dimensions
H×W×D
Type
Coil
Rows×Stages×FPI
Face area
Model
Type
Fan
Motor output
Airflow rate (H/L)
Air filter
Mass (Weight)
Liquid
Piping
Gas
connections
Drain
Wired
Remote controller (option)
Wireless
Outdoor unit
Color
Dimensions
H×W×D
Type
Coil
Rows×Stages×FPI
Face area
Model
Comp.
Type
Motor output
Model
Type
Fan
Motor output
Airflow rate
Mass (Weight)
Liquid
Piping
Gas
connections
Drain
Safety devices
Capacity step
Refrigerant control
Standard length
Ref. piping
Max. length
Max. height difference
Model
Refrigerant
Charge (factory charge)
Model
Ref. oil
Charge
Drawing Number
1. Indoor temp. : 80°FDB, 67°FWB / outdoor temp. : 95°FDB / Equivalent piping length : 25 ft (7.5 m), level difference : 0.
2. Indoor temp. : 70°FDB / outdoor temp. : 47°FDB, 43°FWB / Equivalent piping length : 25 ft (7.5 m), level difference : 0.
Note:
Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
10
FAQ18PVJU
RZQ18PVJU
1 phase 60Hz 208-230V
Btu/h
Btu/h
FAQ18PVJU
White (3.0Y8.5/0.5)
in (mm)
11–3/8 × 41–3/8 × 9" (290 x 1050 x 230 mm)
Cross fin coil
2 × 14 × 18
ft²
QCL9686M
Crossflow fan
W
cfm
Resin net (Washable)
lbs (kg)
φ3/8" (9.5 mm) (Flare connection)
in (mm)
φ5/8" (15.8 mm) (Flare connection)
in (mm)
in (mm) VP13 (External dia. 11/16" (17 mm), Internal dia. 1/2" (12.7 mm) VP13 (External dia. 11/16" (17 mm), Internal dia. 1/2" (12.7 mm))
BRC1D71
BRC7E818
RZQ18PVJU
in (mm)
30–5/16 × 35–7/16 × 12–5/8" (770 x 900 x 320 mm)
Cross fin coil
2 × 34 × 18
ft²
2YC63HXD#ED
Hermetically sealed swing type
kW
P47N11F
Propeller fan
W
cfm
lbs (kg)
150 lbs (68 kg)
φ3/8" (9.5 mm) (Flare connection)
in (mm)
φ5/8" (15.8 mm) (Flare connection)
in (mm)
φ1" (25.4 mm) (Hole)
in (mm)
High pressure switch.
Outdoor fan driver overload protector.
Thermal protector for indoor fan motor.
Inverter overload protector.
Fusible plugs. Fuse.
%
Electronic expansion valve
ft (m)
25'(7.5 m)
ft (m)
164' (50 m)
ft (m)
98' (30 m)
lb
Refer to the name plate of compressor.
L
C : 4D062151D
18,000
20,000
2.29
43
500/400
31(14)
Ivory
7.1
1.7
70
1,835
100-0
R410A
3.3
0.75
EDSUSE28-956S
FAQ24PVJU
RZQ24PVJU
1 phase 60Hz 208-230V
24,000
26,000
FAQ24PVJU
White (3.0Y8.5/0.5)
11–3/8 × 41–3/8 × 9" (290 x 1050 x 230 mm)
Cross fin coil
2 × 14 × 18
2.29
QCL9686M
Crossflow fan
43
635/470
Resin net (Washable)
31(14)
φ3/8" (9.5 mm) (Flare connection)
φ5/8" (15.8 mm) (Flare connection)
BRC1D71
BRC7E818
RZQ24PVJU
Ivory
30–5/16 × 35–7/16 × 12–5/8" (770 x 900 x 320 mm)
Cross fin coil
2 × 34 × 18
7.1
2YC63HXD#ED
Hermetically sealed swing type
1.7
P47N11F
Propeller fan
70
1,835
150 lbs (68 kg)
φ3/8" (9.5 mm) (Flare connection)
φ5/8" (15.8 mm) (Flare connection)
φ1" (25.4 mm) (Hole)
High pressure switch.
Outdoor fan driver overload protector.
Thermal protector for indoor fan motor.
Inverter overload protector.
Fusible plugs. Fuse.
100-0
Electronic expansion valve
25' (7.5 m)
164' (50 m)
98' (30 m)
R410A
3.3
Refer to the name plate of compressor.
0.75
C : 4D062151D
RZQ-P, M series

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents