Be careful not to make mis-wiring.
Firmly tighten the terminal screws to prevent them from loosening.
After tightening, pull the wires lightly to confi rm that they do not move.
If the connecting wire is incorrectly connected to the terminal block, the unit does
not operate normally.
If an earth is incorrect, it may cause an electric shock.

4-5 AUTO RESTART FUNCTION

These models are equipped with an auto restart function. If you do not want to use
this function, please consult the service representative because the setting of the
unit needs to be changed.
When the indoor unit is controlled with the remote controller, the operation mode,
the set temperature, and the fan speed are memorized by the indoor electronic
control P.C. board. The auto restart function sets to work the moment the power
has restored after power failure, then, the unit will restart automatically. If the unit is
operated in
"I FEEL..." or "AUTO" mode before power failure, the operation mode (COOL, DRY
or HEAT) is not stored in the memory. When the main power is turned on, the unit
decides the operation mode by the initial room temperature at restart and starts
operation again.
Operation
1 If the main power (230V AC) has been cut, the operation settings remain.
2 When three minutes have passed after power was restored, the unit will restart
automatically according to the memory.
Notes:
• The operation settings are memorized when 10 seconds have passed after the
remote controller was operated.
• If the main power is turned off or a power failure occurs while AUTO START/STOP
timer is active, the timer setting is cancelled. As these models are equipped with an
auto restart function, the air conditioner starts operating with timer cancelled at the
same time that power is restored.
• If the unit has been off with the remote controller before power failure, the auto
restart function does not work as the power button of the remote controller is off.
• To prevent breaker off due to the rush of starting current, systematize other home
appliances not to turn on at the same time.
4-6 PIPE FORMING
Place the drain hose below the refrigerant piping.
Make sure that the drain hose is not heaved or snaked.
Do not pull the hose to apply the tape.
When the drain hose passes the room, be sure to wrap insulation material
(obtainable at a store) around it.
Wrap the felt tape 7 around the pipe and the drain hose, then put the pipe in the
back space of the indoor unit.
Indoor/outdoor unit
connecting wire A
FOR REAR, RIGHT OR DOWNWARD PIPING
Pipe arrangement
Put the refrigerant piping and the drain hose together, then apply piping tape G to
them.
Be careful drain hose is not
heaved.
Cut off in case of right piping.
Insert the piping and the drain hose into the wall hole sleeve C, and hook the upper
part of the indoor unit on the installation plate 1.
Check if the indoor unit is hooked securely on the installation plate 1 by moving the
unit to left and right.
Thrust the lower part of the indoor unit into the installation plate 1.
CAUTION
Liquid pipe
Gas pipe
Felt tape 7
Firmly apply piping tape G
from the end.
Cut off in case of downward piping.
FOR LEFT OR LEFT-REAR PIPING
Pipe arrangement
Put the refrigerant piping and the drain hose together, then apply felt tape 7 to
them.
Be careful drain
hose is not heaved.
Felt tape 7
Firmly apply felt tape 7 from the end.
(Felt tape 7 overlap width should be 1/3
the tape width.)
REATTACHING DRAIN HOSE
Be sure to reattach the drain hose and the drain cap in case of left or left-rear piping.
Otherwise, it could cause drops of water to drip down from the drain hose.
1 Pull out the drain cap at the rear right of the indoor unit.
Hold the convex section at the end and pull the drain cap.
2 Pull out the drain hose at the rear left of the indoor unit.
Hold the claw marked by the arrow and pull out the drain hose forward.
3 Put the drain cap into the section to which the drain hose is to be
attached at the rear of the indoor unit.
Insert the screwdriver, etc. (not sharp-edged tool) into the hole at the end of the cap and
insert the cap fully into the drain pan.
Cut off in case of left piping.
Use a bandage stopper at
the end of felt tape 7.
Drain cap
Drain cap
Drain hose
Drain cap