Maintenance and Care

Lamp Replacement

When the projection lamp of the projector reaches its end of life, the Lamp replacement icon appears on the
screen and LAMP REPLACE indicator lights orange. Replace the lamp with a new one after it has cooled down.
The timing when the LAMP REPLACE indicator lights up is depending on the mode that you specified for the Lamp
control function.
LAMP REPLACE indicator
LAMP REPLACE indicator
LAMP 1/2/3/4 REPLACE indicators
CAUTION
When replacing the lamp because it has stopped illuminating, there is a possibility that the lamp may be broken.
If replacing a lamp of the projector which has been installed on the ceiling, you should always assume that the
lamp is broken, and you should stand to the side of the lamp cover, not underneath it. Remove the lamp cover
gently. Small pieces of glass may fall out when the lamp cover is opened. If pieces of glass get into your eyes or
mouth, seek medical advice immediately.
Follow these steps to replace the lamp.
Check the LAMP 1/2/3/4 REPLACE indicators on top
1
of the projector. When any of the indicators blinks
rapidly, wait at least 20 minutes until it blinks slowly.
After that, go to the next step. When any of the
indicators blinks slowly, go to the next step.
Loosen the screw on the lamp cover. Open the lamp
2
cover. (See the right upper figure.)
3
Loosen the two screws that securing the lamp and
pull out the lamp by using the handle. (See the right
lower figure.)
Replace the lamp with a new one and tighten the
4
two screws. Make sure the lamp is set properly.
5
Close the lamp cover and tighten the screw.
76
Lamp replacement icon
Allow the projector to cool for at least 20 minutes
before you open the lamp cover. The temperature
inside the projector becomes very hot.
- For continued safety, replace with a lamp assembly
of the same type.
- Do not drop the lamp assembly or touch a glass
bulb! The glass can shatter and may cause injury.
- When replacing the lamp, do it within 30 minutes after
opening the lamp cover.
- Do not insert hand in the empty lamp compartment after
the lamp is removed.
WARNING:
TURN OFF THE UV LAMP BEFORE
OPENING THE LAMP COVER.
CAUTION
CAUTION
SCREW
LAMP 4
LAMP 3
HANDLE
SCREW
LAMP COVER
LAMP 2
SCREW
LAMP 1

Advertisement