Dimplex SI 5MER Installation And Operating Instructions Manual
Dimplex SI 5MER Installation And Operating Instructions Manual

Dimplex SI 5MER Installation And Operating Instructions Manual

Brine-to-water heat pump for indoor installation
Table of Contents
  • Deutsch

    • Table of Contents
    • 1 Bitte Sofort Lesen

      • Wichtige Hinweise
      • Bestimmungsgemäßer Gebrauch
      • Gesetzliche Vorschriften und Richtlinien
      • Energiesparende Handhabung der Wärmepumpe
    • 2 Verwendungszweck der Wärmepumpe

      • Anwendungsbereich
      • Arbeitsweise
    • 3 Grundgerät

    • 4 Zubehör

      • Soleverteiler
    • 5 Transport

    • 6 Aufstellung

      • Allgemeine Hinweise
      • Schallemissionen
    • 7 Montage

      • Allgemein
      • Heizungsseitiger Anschluss
      • Wärmequellenseitiger Anschluss
      • Elektrischer Anschluss
    • 8 Inbetriebnahme

      • Allgemeine Hinweise
      • Vorbereitung
      • Vorgehensweise bei Inbetriebnahme
    • 9 Pflege / Reinigung

      • Pflege
      • Reinigung Heizungsseite
      • Reinigung Wärmequellenseite
    • 10 Störungen / Fehlersuche

    • 11 Außerbetriebnahme / Entsorgung

    • 12 Geräteinformation

    • 13 Garantieurkunde

  • Français

    • 1 Lire IMMédiatement

      • Remarques Importantes
      • Utilisation Conforme
      • Dispositions Légales Et Directives
      • Utilisation de la Pompe À Chaleur Pour Économiser de L'énergie
    • 2 Utilisation de la Pompe À Chaleur

      • Domaine D'utilisation
      • Fonctionnement
    • 3 Appareil de Base

    • 4 Accessoires

      • Distributeur D'eau Glycolée
    • 5 Transport

    • 6 Installation

      • Généralités
      • Emissions Sonores
    • 7 Montage

      • Remarques D'ordre Général
      • Branchement Côté Installation de Chauffage
      • Raccordement Côté Source de Chaleur
      • Branchements Électriques
    • 8 Mise en Service

      • Généralités
      • Préparation
      • Procédures À Suivre Lors de la Mise en Service
    • 9 Entretien / Nettoyage

      • Entretien
      • Nettoyage Côté Chauffage
      • Nettoyage Côté Source de Chaleur
    • 11 Mise Hors Service / Mise Au Rebut

    • 12 Informations Sur Les Appareils

      • Maßbilder / Dimension Drawings / Schémas Cotés
        • Maßbild / Dimension Drawing / Schéma Coté
      • Diagramme / Diagrams / Diagrammes
        • Heizbetrieb / Heating Operation / Mode Chauffage si 5MER
        • Kühlbetrieb / Cooling Operation / Mode Refroidissement si 5MER
        • Heizbetrieb / Heating Operation / Mode Chauffage si 7MER
        • Kühlbetrieb / Cooling Operation / Mode Refroidissement si 7MER
        • Heizbetrieb / Heating Operation / Mode Chauffage si 9MER
        • Kühlbetrieb / Cooling Operation / Mode Refroidissement si 9MER
        • Heizbetrieb / Heating Operation / Mode Chauffage si 11MER
        • Kühlbetrieb / Cooling Operation / Mode Refroidissement si 11MER
      • Stromlaufpläne / Circuit Diagrams / Schémas Électriques
        • Steuerung Standardregler / Control Via the Standard Controller / Commande Régulateur Standard
        • Steuerung Kühlregler / Control Via the Cooling Controller / Commande Régulateur Refroidissement
        • Last / Load / Charge
        • Anschlussplan Standardregler / Terminal Diagram for Standard Controller / Schéma de Branchement du Régulateur Standard
        • Anschlussplan Kühlregler / Terminal Diagram for Cooling Controller / Schéma de Branchement du Régulateur de Refroidissement
        • Legende / Legend / Légende
      • Hydraulisches Prinzipschema / Hydraulic Plumbing Diagram / Schéma Hydraulique
        • Darstellung / Schematic View / Représentation
        • Legende / Legend / Légende
      • Konformitätserklärung / Declaration of Conformity / Déclaration de Conformité

Advertisement

Available languages

Available languages

SI 5MER
SI 7MER
SI 9MER
SI 11MER
Sole/Wasser-
Wärmepumpe für
Innenaufstellung
Bestell-Nr. / Order no. / N
Brine-to-Water
Heat Pump for
Indoor Installation
o
de commande : 452232.66.14
Montage- und
Gebrauchsanweisung
Installation and
Operating Instructions
Instructions d'installation
et d'utilisation
Pompe à chaleur
eau glycolée-eau
pour installation
intérieure
FD 8806

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SI 5MER and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dimplex SI 5MER

  • Page 1 SI 5MER SI 7MER SI 9MER Montage- und SI 11MER Gebrauchsanweisung Installation and Operating Instructions Instructions d’installation et d’utilisation Sole/Wasser- Brine-to-Water Pompe à chaleur Wärmepumpe für Heat Pump for eau glycolée-eau Innenaufstellung Indoor Installation pour installation intérieure Bestell-Nr. / Order no. / N de commande : 452232.66.14...
  • Page 3: Table Of Contents

    Pflege / Reinigung ........................D-7 9.1 Pflege..............................D-7 9.2 Reinigung Heizungsseite ........................D-7 9.3 Reinigung Wärmequellenseite........................D-7 10 Störungen / Fehlersuche ......................D-7 11 Außerbetriebnahme / Entsorgung ....................D-7 12 Geräteinformation ........................D-8 13 Garantieurkunde........................... D-9 Anhang / Appendix / Annexes ......................A-I www.dimplex.de...
  • Page 4: Bitte Sofort Lesen

    Bitte sofort lesen 1.2 Bestimmungsgemäßer Gebrauch 1.1 Wichtige Hinweise Dieses Gerät ist nur für den vom Hersteller vorgesehenen Ver- wendungszweck freigegeben. Ein anderer oder darüber hinaus ACHTUNG! gehender Gebrauch gilt als nicht bestimmungsgemäß. Dazu Die Wärmepumpe ist nicht am Holzrost befestigt. zählt auch die Beachtung der zugehörigen Produktschriften.
  • Page 5: Verwendungszweck Der Wärmepumpe

    Verflüssiger die Wärme an das Kältemittel ab. Mit dem Verdich- ter wird das Kältemittel auf ein höheres Temperaturniveau ge- bracht. Über den Verflüssiger (im Heizbetrieb Verdampfer) ge- langt die Wärme in die Sole und somit ins Erdreich. Verflüssiger Schaltblech Verdampfer Verdichter www.dimplex.de...
  • Page 6: Zubehör

    Zubehör Aufstellung 4.1 Soleverteiler 6.1 Allgemeine Hinweise Der Soleverteiler vereinigt die Kollektorschleifen der Wärmequel- Das Gerät ist nur in nicht feuchten Innenräumen auf einer ebe- lenanlage zu einer Hauptleitung, welche an die Wärmepumpe nen, glatten und waagrechten Fläche aufzustellen. Dabei sollte angeschlossen wird.
  • Page 7: Montage

    Leistungsaufnahme der Wärmepumpe, der technischen Anschlussbedingungen des jeweiligen EVU und nach den einschlägigen Vorschriften zu wählen. Die Leistungs- aufnahme der Wärmepumpe entnehmen Sie der Produktinfor- mation oder dem Typschild. Die Anschlussklemmen sind für max. 10 mm² Leiterquerschnitt ausgelegt. www.dimplex.de...
  • Page 8: Inbetriebnahme

    Inbetriebnahme 8.3 Vorgehensweise bei Inbetriebnahme 8.1 Allgemeine Hinweise Die Inbetriebnahme der Wärmepumpe erfolgt über den Wärme- pumpenregler. Um eine ordnungsgemäße Inbetriebnahme zu gewährleisten, sollte diese von einem vom Werk autorisierten Kundendienst ACHTUNG! durchgeführt werden. Unter bestimmten Bedingungen ist damit Die Inbetriebnahme der Wärmepumpe muss gemäß der Montage- und eine Verlängerung der Gewährleistung verbunden (vgl.
  • Page 9: Pflege / Reinigung

    Schmutzfänger montieren, Verdampfer gegen Verunreinigungen zu schützen. Einen Tag nach der Inbetriebnahme sollte das Filtersieb des Schmutzfängers gereinigt werden, danach wöchentlich reinigen. Sind keine Verunreinigungen mehr erkennbar, kann das Sieb des Schmutzfängers ausgebaut werden, um die Druckverluste zu reduzieren. www.dimplex.de...
  • Page 10: Geräteinformation

    12 Geräteinformation Typ- und Verkaufsbezeichnung SI 5MER SI 7MER SI 9MER SI 11MER Bauform Ausführung Reversibel Reversibel Reversibel Reversibel Schutzart nach EN 60 529 IP 20 IP 20 IP 20 IP 20 Aufstellungsort Innen Innen Innen Innen Leistungsangaben Temperatur-Betriebseinsatzgrenzen: Heizwasser-Vorlauf °C...
  • Page 11: Garantieurkunde

    Teile ersetzt werden. Durch Art oder Ort des Einsatzes des Systemtechnik-Kundendienst erfahren Sie über die zentrale Ser- Gerätes oder schlechte Zugänglichkeit des Gerätes bedingte au- vicehotline der Glen Dimplex Deutschland GmbH. ßergewöhnliche Kosten der Mängelbeseitigung werden nicht übernommen. Der freie Gerätezugang muss durch den Endab- Glen Dimplex Deutschland GmbH nehmer gestellt werden.
  • Page 12 D-10...
  • Page 13 9.1 Maintenance ............................E-7 9.2 Cleaning the Heating System ......................... E-7 9.3 Cleaning the Heat Source System......................E-7 10 Faults / Trouble-Shooting ......................E-7 11 Decommissioning / Disposal .......................E-7 12 Device Information ........................E-8 Anhang / Appendix / Annexes ......................A-I www.dimplex.de...
  • Page 14: Please Read Immediately

    Please Read 1.2 Intended Use Immediately This device is only intended for use as specified by the manufac- turer. Any other use beyond that intended by the manufacturer is prohibited. This requires the user to abide by the manufacturers 1.1 Important Information product information.
  • Page 15: Purpose Of The Heat Pump

    The refrigerant is pumped to a higher temperature level using the compressor. Heat passes into the brine via the liquifier (evaporator in heating operation) and consequently into the ground. Liquifier Control panel Evaporator Compressor www.dimplex.de...
  • Page 16: Accessories

    Accessories Set-up 4.1 Brine Circuit Manifold 6.1 General Information The brine circuit manifold merges the individual collector loops of The unit may only be installed indoors in rooms with low humidity the heat source system into a single main pipe which is con- on a level, smooth and horizontal surface.
  • Page 17: Installation

    Details on the power consumption of the heat pump are listed on both the product information sheet and the type plate. The connection terminals are designed for a max. conductor cross-section of 10mm www.dimplex.de...
  • Page 18: Commissioning

    Commissioning 8.3 Start-up Procedure The heat pump is started up via the heat pump controller. 8.1 General Information ATTENTION! To ensure that start-up is performed correctly, it should only be The heat pump must be started up in accordance with the installation and carried out by an after-sales service technician authorised by the operating instructions of the heat pump controller.
  • Page 19: Maintenance And Cleaning

    Clean the dirt trap’s filter screen one day after start-up and sub- sequently in weekly intervals. If no more signs of contamination are evident, the filter can be removed to reduce pressure drops. www.dimplex.de...
  • Page 20: Device Information

    12 Device Information Type and order code SI 5MER SI 7MER SI 9MER SI 11MER Design Model Reversible Reversible Reversible Reversible Degree of protection according to EN 60 529 IP 20 IP 20 IP 20 IP 20 Installation location Indoors...
  • Page 21 9.2 Nettoyage côté chauffage........................F-7 9.3 Nettoyage côté source de chaleur ......................F-7 10 Défaillances / recherche de pannes .................... F-7 11 Mise hors service / mise au rebut....................F-7 12 Informations sur les appareils .....................F-8 Anhang / Appendix / Annexes ......................A-I www.dimplex.de...
  • Page 22: Lire Immédiatement

    A lire immédiatement ! 1.2 Utilisation conforme Cet appareil ne doit être employé que selon les conditions d'utili- 1.1 Remarques importantes sation prévues par le fabricant. Toute autre utilisation est consi- dérée comme non conforme. Les descriptions accompagnant les produits doivent également être prises en compte. Toute modifi- ATTENTION ! cation ou transformation de l'appareil est à...
  • Page 23: Utilisation De La Pompe À Chaleur

    Le fluide frigorigène est amené à un niveau de température plus élevé à l’aide du compresseur. La chaleur est transmise à l’eau glycolée via le condenseur et de ce fait, à la terre (en mode chauffage via l’évaporateur). Condenseur Panneau de commande Evaporateur Compresseur www.dimplex.de...
  • Page 24: Accessoires

    Accessoires Installation 4.1 Distributeur d'eau glycolée 6.1 Généralités Le distributeur d’eau glycolée réunit les boucles du collecteur de N'installer l'appareil qu'à l'intérieur, dans des pièces non humi- l’installation de source de chaleur pour former une conduite prin- des sur une surface plane, lisse et horizontale. Ici, le châssis de cipale qui, elle, est raccordée à...
  • Page 25: Montage

    Vous trouverez les données sur la puis- sance absorbée par la pompe à chaleur dans le tableau « Carac- téristiques techniques » ou sur la plaque signalétique. Les bor- nes de connexion sont dimensionnées pour une section du conducteur de 10 mm maximum. www.dimplex.de...
  • Page 26: Mise En Service

    Mise en service Température Différence de température max. source de chaleur entre circuits départ et retour du 8.1 Généralités chauffage à -5° C 0° C 10 K Pour garantir une mise en service en règle, cette dernière doit 1° C 5°...
  • Page 27: Entretien / Nettoyage

    Le tamis du filtre du collecteur d’impuretés doit être nettoyé le lendemain de la mise en service, puis toutes les semaines. Si aucune souillure n’est plus à signaler, on pourra démonter le tamis du filtre et réduire ainsi les pertes de pression. www.dimplex.de...
  • Page 28: Informations Sur Les Appareils

    12 Informations sur les appareils Désignation technique et commerciale SI 5MER SI 7MER SI 9MER SI 11MER Forme Version réversible réversible réversible réversible Type de protection selon EN 60 529 IP 20 IP 20 IP 20 IP 20 Emplacement en intérieur en intérieur...
  • Page 29 1.1 Maßbild / Dimension Drawing / Schéma coté..................A-II Diagramme / Diagrams / Diagrammes ..................A-III 2.1 Heizbetrieb / Heating operation / Mode chauffage SI 5MER ..............A-III 2.2 Kühlbetrieb / Cooling operation / Mode refroidissement SI 5MER ............A-IV 2.3 Heizbetrieb / Heating operation / Mode chauffage SI 7MER ..............A-V 2.4 Kühlbetrieb / Cooling operation / Mode refroidissement SI 7MER ............A-VI...
  • Page 30: Maßbilder / Dimension Drawings / Schémas Cotés

    1 Maßbilder / Dimension Drawings / Schémas cotés 1.1 Maßbild / Dimension Drawing / Schéma coté A-II...
  • Page 31: Diagramme / Diagrams / Diagrammes

    2 Diagramme / Diagrams / Diagrammes 2.1 Heizbetrieb / Heating operation / Mode chauffage SI 5MER www.dimplex.de A-III...
  • Page 32: Kühlbetrieb / Cooling Operation / Mode Refroidissement Si 5Mer

    2.2 Kühlbetrieb / Cooling operation / Mode refroidissement SI 5MER A-IV...
  • Page 33: Heizbetrieb / Heating Operation / Mode Chauffage Si 7Mer

    2.3 Heizbetrieb / Heating operation / Mode chauffage SI 7MER www.dimplex.de...
  • Page 34: Kühlbetrieb / Cooling Operation / Mode Refroidissement Si 7Mer

    2.4 Kühlbetrieb / Cooling operation / Mode refroidissement SI 7MER A-VI...
  • Page 35: Heizbetrieb / Heating Operation / Mode Chauffage Si 9Mer

    2.5 Heizbetrieb / Heating operation / Mode chauffage SI 9MER www.dimplex.de A-VII...
  • Page 36: Kühlbetrieb / Cooling Operation / Mode Refroidissement Si 9Mer

    2.6 Kühlbetrieb / Cooling operation / Mode refroidissement SI 9MER A-VIII...
  • Page 37: Heizbetrieb / Heating Operation / Mode Chauffage Si 11Mer

    2.7 Heizbetrieb / Heating operation / Mode chauffage SI 11MER www.dimplex.de A-IX...
  • Page 38: Kühlbetrieb / Cooling Operation / Mode Refroidissement Si 11Mer

    2.8 Kühlbetrieb / Cooling operation / Mode refroidissement SI 11MER...
  • Page 39: Stromlaufpläne / Circuit Diagrams / Schémas Électriques

    3 Stromlaufpläne / Circuit Diagrams / Schémas électriques 3.1 Steuerung Standardregler / Control via the standard controller / Commande régulateur standard www.dimplex.de A-XI...
  • Page 40: Steuerung Kühlregler / Control Via The Cooling Controller / Commande Régulateur Refroidissement

    3.2 Steuerung Kühlregler / Control via the cooling controller / Commande régulateur refroidissement A-XII...
  • Page 41: Last / Load / Charge

    3.3 Last / Load / Charge www.dimplex.de A-XIII...
  • Page 42: Anschlussplan Standardregler / Terminal Diagram For Standard Controller / Schéma De Branchement Du Régulateur Standard

    3.4 Anschlussplan Standardregler / Terminal diagram for standard controller / Schéma de branchement du régulateur standard A-XIV...
  • Page 43: Anschlussplan Kühlregler / Terminal Diagram For Cooling Controller / Schéma De Branchement Du Régulateur De Refroidissement

    3.5 Anschlussplan Kühlregler / Terminal diagram for cooling controller / Schéma de branchement du régulateur de refroidissement www.dimplex.de A-XV...
  • Page 44: Legende / Legend / Légende

    3.6 Legende / Legend / Légende Drahtbrücke, muss eingelegt werden, wenn kein Wire jumper, must be inserted if no blocking con- Le cavalier à fil doit être inséré en absence de disjoncteur Sperrschütz vorhanden ist tactor is fitted de blocage du fournisseur d'énergie. Drahtbrücke, muss bei Verwendung des 2ten Wire jumper, must be removed if the 2nd disable Cavalier à...
  • Page 45: Hydraulisches Prinzipschema / Hydraulic Plumbing Diagram / Schéma Hydraulique

    4 Hydraulisches Prinzipschema / Hydraulic Plumbing Diagram / Schéma hydraulique 4.1 Darstellung / Schematic View / Représentation www.dimplex.de A-XVII...
  • Page 46: Legende / Legend / Légende

    4.2 Legende / Legend / Légende Absperrventil Shutoff valve Robinet d’arrêt Absperrventil mit Entwässerung Shutoff valve with drainage Robinet d’arrêt avec écoulement Sicherheitsventil Safety valve Vanne de sécurité Umwälzpumpe Circulating pump Circulateur Ausdehnungsgefäß Expansion vessel Vase d´expansion Raumtemperaturgesteuertes Ventil Room temperature-controlled valve Vanne commandée par température Absperrventil mit Rückschlagventil Shutoff valve with check valve...
  • Page 47: Konformitätserklärung / Declaration Of Conformity / Déclaration De Conformité

    5 Konformitätserklärung / Declaration of Conformity / Déclaration de conformité www.dimplex.de A-XIX...
  • Page 48 Glen Dimplex Deutschland GmbH Irrtümer und Änderungen vorbehalten. Geschäftsbereich Dimplex Subject to alterations and errors. Am Goldenen Feld 18 Sous réserve d’erreurs et modifications. D-95326 Kulmbach +49 (0) 9221 709 565 www.dimplex.de...

This manual is also suitable for:

Si 11merSi 7merSi 9mer

Table of Contents