Introduction
Your Baxi Bermuda PW5 Deluxe, C5
or C5W is a central heating boiler
combined with a gas fire. Normally
the fire will heat the room in which it
is situated and the boiler will provide
heating for the rest of the house and
also domestic hot water if required.
The boiler and fire are independently
controlled.
The boiler may be controlled by an
external programmer or clock control
(see separate instructions with the
clock controller used). The fire is
controlled by the knob which is
located on the right hand side of the
outer case (PW5 Deluxe model) on
top of the outer case (C5/C5W
models).
Important Notice
The Bermuda C5 Propane & C5W
(Mahogany) Propane are for use on
PROPANE GAS ONLY and cannot
be used on any other gas.
Propane appliances can be converted
to operate on Natural Gas if required
at a later date. Consult your Installer.
WARNING
Bermuda PW5 Deluxe, C5 and C5W
Renewal Firefronts MUST NEVER be
fitted as independent gas fires without
the boiler.
NOTE:
When your Bermuda is first used
it is possible that certain smells may be
emitted. These smells will quickly clear
with use.
Most heating appliances generate warm
air convection currents and transfer heat
to any wall surface against which they
are situated. Some soft wall furnishings
(such as blown vinyl wallpapers) may not
be suitable for use where they are
subjected to temperatures above normal
room levels. The manufacturers advice
should be sought before using this type
of wall covering adjacent to any heating
appliance. The likelihood of wall staining
from convected air currents will be
increased in environments where high
levels of tobacco smoke or other
contaminants exist.
Pilot Viewing Window
Indicator Light
Electronic Controls Boiler
(51/5)
PW5 Deluxe
Controls
Cover Panel
C5W
Controls
Cover Panel
C5
Controls
Cover Panel
(C5 shown) Controls
Cover Panel removed
Pilot Viewing Window
(401 Boiler)
Plug &
Socket
Thermostat
Igniter Button
Knob
Manual Controls Boiler
(401, 552 & 553 Propane)
Pilot Viewing Window (Series 4)
Igniter
Pilot Viewing
Button
Mirror (Series 3)
Thermostat Knob
Manual Controls Boiler
(45/3M, 57/3M, 45/4M & 57/4M)
Pilot Viewing Window (Series 4)
Boiler Lockout Light
Thermostat
Knob
Pilot Indicator Light
Electronic Controls Boiler
(45/3E, 57/3E, 45/4E & 57/4E)

OPERATING THE UNIT

Baxi Bermuda
PW5 Deluxe
Fire Control Knob
Manual
Controls
Boiler
Fire Control Knob
(C5 shown)
Boiler Controls
Pilot Viewing Window
(552Boiler & 553
Propane)
Service
Tap
Grey Push
Button
Service Tap
Grey Push
Button
Thermostat
Service
Tap
Knob
page 4
1
Push in and turn the fire control
knob to the OFF position ( ).
2
Remove the controls cover panel
at the bottom of the fire by
grasping it firmly by its side edges
and pulling forwards.
3
Turn the boiler thermostat knob
to the OFF position ( ).
Electronic
Controls
Boiler
4
Ensure the main gas and
electricity supplies are turned on.
5
TO LIGHT THE BOILER PILOT:
(Manual Controls Boiler) Hold in
the grey push button on the gas
control valve. Looking through the
pilot viewing window or mirror: Press
the igniter button and release. Repeat
until the pilot lights.Continue to hold in
the grey push button for a further 15
seconds. The pilot should stay alight.
NOTE:
If the pilot fails to remain alight or
is extinguished at any time, wait at least 3
minutes then repeat step 5. Once the pilot
is alight it may be left on permanently.
Grey Push Button
Igniter Button
6
TO
LIGHT
THE
(Manual
Controls
Ensure that all external controls, e.g.
room thermostat, timer etc., are
calling for heat. Turn the boiler
thermostat knob to the desired
position.
7
TO
LIGHT
THE
(Electronic Controls Boiler)
Ensure that all external controls, e.g.
room thermostat, timer etc., are
calling for heat. To operate the pilot
turn the thermostat knob to the
desired position. The indicator light
on the control box will illuminate once
the pilot is lit. The burner will also
light shortly after the pilot has been
established.
To adjust the boiler temperature:
Turn the boiler thermostat knob
clockwise to the required setting. The
optimum boiler thermostat setting
depends upon type of system,
external
controls
requirements. Your Installer will be
able to advise you on this matter.
If the boiler cannot be lit by the
above method consult your
Service Engineer.